Direct fixed clay brick slip external wall insulation (EWI) system.

Jump to:
+44 (0)118 963 5900 Website

Application

Mechanically and adhesively fixed to either sheathed light gauge steel frame or masonry, concrete, block or no-fines supporting walls.

Description

The AlivaBrick M system consists of mineral wool insulation boards which are mechanically and adhesively fixed to either sheathed light gauge steel frame or masonry, concrete, block or no-fines supporting walls. A layer of basecoat with reinforcement mesh is applied to the mechanically fixed insulation boards and the finishes applied. The system is then finished with a clay brick slip by embedding the slips into a cementitious bedding mortar and finished with a cement pointing grout.

Features and benefits:

  • Mechanical fixed with supplementary adhesive or adhesively fixed with supplementary mechanical fixings.
  • Finished with a clay brick slip from 9–25 mm thickness.
  • Class A1 fire classification to BS EN 13501-1:2019 (surface spread of flame).
  • The system when installed to specification will achieve a design life of in excess of 30 years.
  • KIWA BDA and BBA certified.

Approved substrates:

  • Lightweight steel frames with cement or calcium silicate sheathing boards.
  • Masonry, concrete, blockwork, aerated block and no-fines concrete.

General information

Color

Red

Finish

Brick

Material

Clay

Mineral wool

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_45_72_28 External wall insulation systemsPrimary

CAWS

M21/210 Rendered external wall insulation systems

M21/20 External wall insulation systems

Specification data - External wall insulation systems

Description

Direct fixed external wall insulation system (EWI/ETICS) using mineral wool insulation with a clay/ masonry slip finish.

System performance

A1 surface spread of flame fire rating to BS EN 13501-1.

System manufacturer

Aliva UK Ltd.

Preparation

-

Manufacturer guidance

Wall should have specified sheathing board, with all joints filled or taped and be free from dirt or other materials which will effect the system installation.

Support rails and brackets

-

Fixing method

-

Material

Mechanically fixed with supplementary adhesive.

Boards

-

Material

-

Manufacturer guidance

Required to support the system.

Supplied by others - insert requirements.

Fixings

-

Manufacturer guidance

Supplied by others - insert requirements.

Insulation

-

Material

Mineral wool EWI slab insulation boards.

Adhesive

Adhesive layer to rear of board.

Additional mechanical fixings

Mechanical fixing.

Guidance for specification option:

Consult manufacturer for details.

Fire barriers and stops

-

Material

Not required.

Fixings

Not required.

Beads and trims

Nylon beads and trims.
Stainless steel beads and trims.

Movement joints

-

Form with

10 mm vertical movement joints.
10 mm horizontal movement joints unless deflection is advised as being greater than 10 mm.

Sealant

Low modulus neutral cure external grade silicone mastic.

Render carrier or reinforcement

-

Material

Reinforcing mesh.

Mesh size

50 m² roll, 1 m width.
55 m² roll, 1 m width.

Fixings

Mechanical fixings used with nylon or stainless steel washers.

Render

-

Application

Trowel applied polymer modified cementitious basecoat - mesh layer.

Manufacturer guidance

Render applied to face of mineral wool EWI slab insulation board.

Material

Polymer modified cementitious base coat.

Decorative finish

Clay brick slips, 9–25 mm thick, finished with a cement pointing grout.

Colour

-

Manufacturer guidance

Available in a wide range of colours and finishes.

Consult manufacturer for details and insert requirements.

Protective coating

Not applicable.

Sustainability data

Material

Clay
Mineral wool

Expected Life

30 year

Guidance for specification option:

The system when installed to specification will achieve a design life of in excess of 30 years.