Verified by manufacturer 2 months ago
Stainless steel heavy duty floor access covers for up to 6.5 tonne pneumatic tyre wheel load (C250).
Suitable for floors in demanding environments or high traffic areas.
The 1050 Series is available in single, duct or multipart configurations for use in interior or exterior areas, with 6.5 tonne pneumatic tyre wheel load, FACTA C supplied as standard or up to 11 tonne pneumatic tyre wheel load, FACTA D (equivalent to D400) available on request. Manufactured in the UK and third party CERTIFIRE fire rated to BS 476-22, all covers are manufactured to an exact specification with no time or cost constraint.
Features and benefits:
Color | Silver |
Material | Stainless steel |
Shape | Square Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | 105 mm |
Uniclass | |
CAWS | P30/301 Access covers, manhole tops and frames P31/370 Access covers/ gratings R12/471 Access covers and frames |
Product range |
Certification | CERTIFIRE fire rated to BS 476-22. |
Configuration | Multipart. |
Finish | Galvanized steel |
Clear opening (minimum) | Guidance for specification option: As required. Please consult manufacturer and insert requirements. |
Load class (minimum) | C 250.D 400.Manufacturer guidanceUp to 6.5 tonne pneumatic tyre wheel load (FACTA C) as standard or up to 11 tonne pneumatic tyre wheel load (FACTA D, equivalent to D400) on request. |
Frame or support | Stainless steel.Manufacturer guidanceShow edge manufactured from stainless steel with steel baseplate and reinforcement. Galvanized carbon steel support beams and pockets (where necessary). |
Integral accessories | None.Recessed support beam pockets.Lifting points.Guidance for specification option: Barrel only or inset options. Sets of combined lifting/ securing keys.Cover skate lifting device.Surface mounted support beam pockets. |
FrameSize | Guidance for specification option: Because of the potentially complex design layout of multipart layouts, Howe Green recommends early consultation with their Technical department to achieve the optimum and economical layout for the given installation. |
Cover and frame | Stainless steel, grade 1.4301 (304). Guidance for specification option: Standard. Stainless steel, grade 1.4401 (316). |
Base plate | Galvanized steel. Guidance for specification option: Standard. Stainless steel, grade 1.4301 (304). Stainless steel, grade 1.4401 (316). |
FireRating | Two hours. Guidance for specification option: To BS 476-20. With full C40 concrete infill: fire rated for 2 hours on integrity and 1 hour for insulation. With stone, tile or other non-combustible surface finish: fire rated for 2 hours on integrity only. Any floor access covers outside of the maximum sizes shown above will not be covered by the fire ratings. |
Sealing | Double sealed with socket head securing bolts. Unsealed with blanking bolts. |
Depth | 105 mm. |
Material | Stainless steel |
1050 Series (Stainless Steel) Duct
1050 Series (Stainless Steel) Single Cover
2500 Series (Wood Floor) Access Cover
5 Bar Series tread plates (Aluminium) Duct
5 Bar Series tread plates (Aluminium) Single Cover
5000 Series (Aluminium) Duct
5000 Series (Aluminium) Multipart
5000 Series (Aluminium) Single Cover
5000 Series (Stainless Steel) Duct
5000 Series (Stainless Steel) Multipart