Metsec SFS infill wall with RCM Y-Wall sheathing board, Siniat plasterboard, and Knauf Rocksilk Rainscreen (external)
Metsec SFS infill wall with RCM Y-Wall sheathing board, Siniat plasterboard, and Knauf Rocksilk Rainscreen (external)
Metsec SFS infill wall with RCM Y-Wall sheathing board, Siniat plasterboard, and Knauf Rocksilk Rainscreen (external)

Verified 19 days ago

Metsec (voestalpine Metsec)

Verified 19 days ago

Metsec (voestalpine Metsec)

Verified 19 days ago

Metsec (voestalpine Metsec)
Summary
Metsec SFS infill wall with RCM Y-Wall sheathing board, Knauf Rocksilk Rainscreen (external), and Siniat Fire Board (2x12.5) lining.
-
-
Application

SFS light gauge galvanised steel structural framing systems provide a fast, light, easily erected alternative

voestalpine Metsec’s metal stud steel framing systems are today specified across countless construction projects, especially for medium-rise commercial, retail, healthcare, educational and municipal applications.

voestalpine Metsec Steel Framing Solution (SFS) is a fast-track metal (galvanised steel) stud panel framing system providing a carrier for insulation, exterior cladding and interior boarding. Cold-rolled galvanized steel sections are typically supplied to site as individual components which are assembled in-situ using screwed connections. Components can be supplied pre-cut to required lengths or cut as needed on site.

A full end-to-end service includes structural technical design and due diligence backed by Professional Indemnity Insurance. In-house manufacturing ensures the highest production quality with capacity to meet the most demanding project schedules.

-
-
Description

Metsec SFS infill wall with RCM Y-Wall sheathing board, Knauf Rocksilk Rainscreen (external), and Siniat Fire Board (2x12.5 or 15mm) lining.

 

Resistance to Fire:

voestalpine Metsec’s fire test data for infill walling is to BS EN 1364‑1: 2015. All test data is based on unique UKAS accredited tests and UKAS accredited scope of testing.

 

2x12.5mm Fire Board 

Fire Performance - Non-Boundary Wall: 60,90,120 Minutes (E)

  • Assessment Reference - Internal: BRE-102396-1023A

Fire Performance - Boundary Wall: 60,90,120 Minutes (EI)

  • Assessment Reference - Internal: BRE-102396-1023A
  • Assessment Reference - External: BRE-102396-1023A

MetWALL Perform Warranty

MetWALL Perform, an industry changing warranty giving architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems.

This is an important addition to voestalpine Metsec’s unique Framing range providing warranted, UKAS tested wall combinations, enabling clients to select the most cost-effective performance design solutions. 

 

Metsec Decarb

voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to our product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.

 

System Codes

EXXX-Y1-N090-S22, EXXX-Y1-N100-S22, EXXX-Y1-N120-S22, EXXX-Y1-N150-S22, EXXX-Y1-N180-S22, EXXX-Y1-N200-S22, EXXX-Y1-N210-S22, EXXX-Y1-N240-S22, EXXX-Y1-N270-S22, EXXX-Y1-N300-S22, EXXX-Y1-N350-S22

-
-
Product certifications
-
-
Digital objects
-
-
Finish
Galvanized
-
-
Material
Steel, Plasterboard
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-
SKU Code
EXXX-Y1-N090-S22
-
-

Specification

Classification data
System performance
Structural design supervision and checking. Design of framing systems generally.
-
-
Framing members
Cold-formed galvanized steel sections.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By structural engineer's design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Insulation
Knauf Rocksilk Rainscreen (external).
-
-
Sheathing board
RCM Y-Wall - 12 mm.
-
-
Framing
Metsec SFS 90 mm stud depth.
-
-
Inner layer
Siniat GTEC Fire Board, 12.5 mm.
-
-
Face layer
Siniat GTEC Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap / partition brace.
-
-
Internal face
120/ 120 minutes (insulation/ integrity).
-
-
External face
120/ 120 minutes (insulation/ integrity).
-
-
Fire performance
120 minutes (boundary wall); 120 minutes (non-boundary wall).
-
-
Thermal performance (U-value maximum)
Variable.
-
-
Air tightness
Variable.
-
-
Dimensional constraints
Variable.
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel, Plasterboard
-
-
Recyclability
SFS Light Gauge Steel 95-100%
-
-
Recycled content
60 %
-
-