NBS Source
I'm a manufacturer

Compare variants

AluK 58BW HI Window System - Aluminium Window
AluK 58BW HI Window System - Aluminium Window

Last verified by manufacturer 8 months ago

AluK (GB) Ltd

Open-In - 58BW TBT HI

Last verified by manufacturer 8 months ago

AluK (GB) Ltd

Open-Out - 58BW Casement HI

Summary
Aluminium high insulated window system
Aluminium high insulated window system
Application
  • Suitable for use with residential new build and refurbishment projects.
  • Suitable solution for high rise buildings where internal glazing and ease of cleaning are essential.
  • Suitable for use with residential new build and refurbishment projects.
  • Suitable solution for high rise buildings where internal glazing and ease of cleaning are essential.
Description

Built to the highest UK standards, the 58BW Window System delivers a high performance and cost-effective solution with narrow profiles. The system is available in a number of configurations and in addition to being certified under Secured By Design and tested to PAS 24, the 58BW also holds a Green Guide ‘A’ rating.


Features and benefits:

  • Certified under the Secured By Design scheme.
  • Tested to PAS 24.
  • Green guide rated A.
  • Integrated deep head profiles for ease of trickle ventilation.
  • Distinctive polyamide thermal break design to improve thermal performance.
  • Available for Lifetime Homes (LFT).
  • Glazing 24–40 mm.
  • Available in a range of configurations with open-in and open-out options.

Built to the highest UK standards, the 58BW Window System delivers a high performance and cost-effective solution with narrow profiles. The system is available in a number of configurations and in addition to being certified under Secured By Design and tested to PAS 24, the 58BW also holds a Green Guide ‘A’ rating.


Features and benefits:

  • Certified under the Secured By Design scheme.
  • Tested to PAS 24.
  • Green guide rated A.
  • Integrated deep head profiles for ease of trickle ventilation.
  • Distinctive polyamide thermal break design to improve thermal performance.
  • Available for Lifetime Homes (LFT).
  • Glazing 24–40 mm.
  • Available in a range of configurations with open-in and open-out options.
Product certifications
Finish
Anodized, Powder-coated, Coated, Matt, Mill, Metallic, Pre-treated, Painted, Satin, Semi-gloss, Gloss
Anodized, Powder-coated, Coated, Matt, Mill, Metallic, Pre-treated, Painted, Satin, Semi-gloss, Gloss
Material
Aluminium, Glass
Aluminium, Glass
Shape
Rectangle, Square
Rectangle, Square
Length
Bespoke
Bespoke
Width
Bespoke
Bespoke
Height
Bespoke
Bespoke
Warranty description
Ten year
Ten year

Specification

Dimensions and configurations
Open-in, side hung., Open-in, bottom hung., Open-in, tilt and turn., Open-in, fixed light., Open-in, multi-light.
Open-out, top hung., Open-out, side hung., Open-out, bottom hung., Open-out, fixed light., Open-out, multi-light., Open-out, French casement.
Product performance
-
-
Fire performance
-
-
Fire resistance
Not available.
Not available.
Fire egress
Not available.
Not available.
Weather performance
-
-
Air permeability
Class 4 (600 Pa).
Class 4 (600 Pa).
Watertightness
Class 8A (600 Pa).
Class 9A (600 Pa).
Resistance to wind load
Class E2400 (2400 Pa).
Class E2400 (2400 Pa).
Safety
-
-
Anti-ligature standard
Not available.
Not available.
Security level
To PAS 24. To Secured by Design standard.
To PAS 24. To Secured by Design standard.
Environmental
-
-
Acoustic performance rating
44 (-1;-4) dB Rw.
42 (-1;-5) dB Rw.
Thermal
-
-
Whole window U-value
1.4 W/m²K (double glazing). 1.2 W/m²K (triple glazing).
1.4 W/m²K (double glazing). 1.2 W/m²K (triple glazing).
British Fenestration Rating Council Window Energy Rating
B–C.
B–C.
Frame
-
-
Profile
Aluminium section with polyamide thermal break.
Aluminium section with polyamide thermal break.
Finish as delivered
-
-
Coating
Anodized., Powder-coated., Coated., Matt., Mill., Metallic., Painted., Satin., Semi-gloss., Gloss., Pre-treated.
Anodized., Powder-coated., Coated., Matt., Mill., Metallic., Painted., Satin., Semi-gloss., Gloss., Pre-treated.
Film thickness (minimum)
60 microns (minimum average).
60 microns (minimum average).
Glazing or infill
-
-
Requirements
-
-
Operation
-
-
Type
Manual.
Manual.
Fixing features
Fixing straps.
Fixing straps.

Additional properties

Sightline
Frame to vent: 86 mm.
Vent to mullion: 100 mm.
Fixed light: 43 mm.
Frame to vent: 75 mm.
Vent to mullion: 89 mm.
Fixed light: 43 mm.
System depth
58 mm., 70 mm.
58 mm., 70 mm.
Options
Bay., Contemporary.
Bay., Contemporary., Chamfered., Ovolo.
Green guide rating
A rated.
A rated.

Sustainability data

Contains Red List materials
No
No
Country of product manufacture
United Kingdom
United Kingdom
A1–A3 ('Production stage')

Embodied carbon as defined in BS EN 15804

Lower emissions

Lower emissions

Normalized unit
2 kg CO₂ eq/kg
2 kg CO₂ eq/kg
Declared unit
2.0 kg CO₂ eq/kg
2.0 kg CO₂ eq/kg
Recyclability
95%
95%
Recycled content
80 %
80 %