NBS Source
I'm a manufacturer

Compare variants

SPEEDLINE Single Frame Partition Systems Utilising Knauf Performance Plus
SPEEDLINE Single Frame Partition Systems Utilising Knauf Performance Plus

Verified 3 months ago

Metsec (voestalpine Metsec)

PSHD70-K-63

Verified 3 months ago

Metsec (voestalpine Metsec)

PSHD70-K-63(25)

Summary
An economical friction-fit system to assemble frames for strong, compact and lightweight non load‑bearing partition.
An economical friction-fit system to assemble frames for strong, compact and lightweight non load‑bearing partition.
Application

Sectors:

  • Residential.
  • Offices.
  • Healthcare.
  • Education.
  • Commercial.
  • Retail.
  • RMI.
  • Student accommodation.

Sectors:

  • Residential.
  • Offices.
  • Healthcare.
  • Education.
  • Commercial.
  • Retail.
  • RMI.
  • Student accommodation.
Description

An economical friction-fit system to assemble frames for strong, compact, lightweight non-load‑bearing partitions, Speedline Partitioning Systems are suitable for use in domestic and commercial situations.


Features and benefits:

  • Quick to erect, lightweight and clean.
  • Metal stud is dimensionally accurate and will not twist or bow.
  • Services are easy to install.
  • Acoustic insulation can easily be installed to uprate sound insulation.
  • Easy to cut to length using tin snips.
  • Frames easily fit together.
  • Door frames simply formed.
  • Range of UKAS accredited tests available for Fire (30-120 mins.) and Acoustics (37-60 dB).

Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.

An economical friction-fit system to assemble frames for strong, compact, lightweight non-load‑bearing partitions, Speedline Partitioning Systems are suitable for use in domestic and commercial situations.


Features and benefits:

  • Quick to erect, lightweight and clean.
  • Metal stud is dimensionally accurate and will not twist or bow.
  • Services are easy to install.
  • Acoustic insulation can easily be installed to uprate sound insulation.
  • Easy to cut to length using tin snips.
  • Frames easily fit together.
  • Door frames simply formed.
  • Range of UKAS accredited tests available for Fire (30-120 mins.) and Acoustics (37-60 dB).

Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.
Product certifications
Length
Bespoke
Bespoke
Width
102 mm
102 mm
Height
Bespoke
Bespoke

Specification

Framing
Speedline Heavy Duty 'C' Stud, 70 mm.
Speedline Heavy Duty 'C' Stud, 70 mm.
Linings
-
-
Outer layers
Knauf Impact Panel, 15 mm.
Knauf Impact Panel, 15 mm.
Fasteners
Speedline Drywall Screws.
Speedline Drywall Screws.
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
Insulation
-
Acoustic partition roll, 25 mm.

Additional properties

Fire resistance
To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation).
To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation).
Partition height
-
-
NominalThickness
102 mm.
102 mm.
Calculated weighted sound reduction index (Rw)
39 Rw dB.
43 Rw dB.
Centres
600 mm., 400 mm., 300 mm.
600 mm., 400 mm., 300 mm.
StrengthGrade
Severe duty.
Severe duty.
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.