NBS Source
I'm a manufacturer

Compare variants

TRADELINE Twin Frame Braced C Stud Partition Systems Utilising British Gypsum Board
TRADELINE Twin Frame Braced C Stud Partition Systems Utilising British Gypsum Board
TRADELINE Twin Frame Braced C Stud Partition Systems Utilising British Gypsum Board

Verified 5 months ago

Metsec (voestalpine Metsec)

Verified 5 months ago

Metsec (voestalpine Metsec)

Verified 5 months ago

Metsec (voestalpine Metsec)
Summary
Twin Frame Braced C Stud Plasterboard partition system.
Third party certification
Length
Bespoke
-
-
Width
200 mm, 220 mm, 240 mm, 250 mm
-
-
Height
Bespoke
-
-

Specification

Framing
Twin Tradeline 'C' Stud, braced, 50 mm.
-
-
Insulation
Acoustic partition roll, 50+50 mm.
-
-
Linings
-
-
-
Inner layers
British Gypsum Gyproc SoundBloc, 12.5 mm.
-
-
Face layer
British Gypsum Gyproc SoundBloc, 12.5 mm.
-
-
Fasteners
Tradeline Drywall Screws.
-
-
Joint treatment
Tradeline Joint Tape., Tradeline Paper Joint Tape., Tradeline Light Weight All Purpose Joint Compound., Tradeline Metal Corner Tape., Tradeline Flexible Metal Corner Tape., Tradeline Scrim Tape., Tradeline Drywall Self-Adhesive Joint Tape.
-
-
System accessories
Tradeline Acoustic Intumescent Sealant., Tradeline PB24 Partition Brace., Tradeline FS24 Flat Bracing Strip., Tradeline ASP19B Plywood Service Support Plates.
-
-

Additional properties

Fire resistance
To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation).
-
-
Nominal thickness
240 mm.
-
-
Calculated weighted sound reduction index (Rw)
63 Rw dB.
-
-
Centres
600 mm.
-
-
StrengthGrade
Severe duty.
-
-
Head/ Floor channel
Tradeline Standard Track., Tradeline 32 mm Leg Track., Tradeline Deep Track., Tradeline Extra Deep Track.
-
-
Standards
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.
-
-