NBS Source
I'm a manufacturer

Compare variants

SPEEDLINE Single Frame Resilient Bar Partition Systems Utilising Knauf Board
SPEEDLINE Single Frame Resilient Bar Partition Systems Utilising Knauf Board
SPEEDLINE Single Frame Resilient Bar Partition Systems Utilising Knauf Board

Verified 3 months ago

Metsec (voestalpine Metsec)

RB92-K-60(50)

Verified 3 months ago

Metsec (voestalpine Metsec)

RB70-K-59(50)

Verified 3 months ago

Metsec (voestalpine Metsec)

RB70-K-60(50)

Summary
Plasterboard partition system.
Plasterboard partition system.
Plasterboard partition system.
Third party certification
Length
Bespoke
Bespoke
Bespoke
Width
138 mm, 148 mm
138 mm, 148 mm
138 mm, 148 mm
Height
Bespoke
Bespoke
Bespoke

Specification

Framing
Speedline 92 mm 'C' Stud with Speedline Resbar on one side only.
Speedline 70 mm 'C' Stud with Speedline Resbar on one side only.
Speedline 70 mm 'C' Stud with Speedline Resbar on one side only.
Insulation
Acoustic partition roll, 50 mm.
Acoustic partition roll, 50 mm.
Acoustic partition roll, 50 mm.
Linings
-
-
-
Inner layers
Knauf Soundshield Plus, 15 mm.
Knauf Soundshield Plus, 12.5 mm.
Knauf Soundshield Plus, 15 mm.
Outer layers
Knauf Soundshield Plus, 15 mm.
Knauf Soundshield Plus, 12.5 mm.
Knauf Soundshield Plus, 15 mm.
Fasteners
Speedline Drywall Screws.
Speedline Drywall Screws.
Speedline Drywall Screws.
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.

Additional properties

Fire resistance
To BS 476:1987:Part 22, 120/ 120 minutes (Integrity/ Insulation).
To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation).
To BS 476:1987:Part 22, 120/ 120 minutes (Integrity/ Insulation).
Partition height
-
-
-
Nominal thickness
148 mm.
148 mm.
138 mm.
Calculated weighted sound reduction index (Rw)
57 Rw dB.
58 Rw dB.
61 (-2;-7) Rw dB (C;Ctr).
Centres
600 mm.
600 mm.
600 mm.
StrengthGrade
Severe duty.
Severe duty.
Severe duty.
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Standards
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.