NBS Source
List your products

Cut Edge Corrosion Treatment, Wirral

by Liquasil Ltd

  Favourite

This metal roof had already been treated with a well known cut edge corrosion system, which had begun to fail in multiple areas due to water becoming trapped between the overlapping roof sheets, which had been sealed with silicone sealant. Flexlap system is made from a specially hardened silicone, designed to resist environmental dirt pick-up as well as providing a much smoother finish. Liquasil does not recommend that the gap between overlapping roof sheets is sealed. Any moisture that might be present can escape or evaporate naturally, which is how built-up steel profile roofs are designed to work.

Read more

No featured products in this case study

Contact Liquasil Ltd by clicking the button below to find out which products were used in this case study.