NBS Source
I'm a manufacturer

Future Proofing Waterproofing Multi Level Commercial New Build Structure

OVERVIEW

Delta’s Structural Waterproofing Consultant, Paul Green, CSSW alongside Delta’s MD, Kevin Dodds, were appointed to the design team to collaborate with the Architects, Engineers, Main and Sub-Contractors to fulfil the role of Waterproofing Design Specialists in providing a reliable, watertight solution for this substantial project.


The large-scale basement project consists of a 4-storey deep

basement located close to the River Thames in Central London.


The proposed subterranean space would offer multiple usage. This complex project required a waterproofing design which is, able to cope with intermittent/regular hydrostatic pressures created not just by groundwater, but also geographical tidal impacts from the river Thames and potential stress challenges caused by the surrounding infrastructure such as heavily trafficked railway lines in the development’s vicinity.


Structures that experience a high level of vibration from

surrounding infrastructure can, over time, have a high propensity to suffer cracks, which could lead to failure of some waterproofing solutions, so therefore careful considerations should be incorporated into the overall waterproofing design from those aspects and, the impacts these factors can have on an elected waterproofing system.

Delta’s design philosophy rotated around creating a robust and suitable waterproofing design, the structure design, a continuous system, sequencing and installation, future maintenance, and serviceability, whilst able to fulfil requirements set out in BS 8102:2022 Protection of below ground structures against water ingress. Code of practice. The British Standard which governs waterproofing of substructures.

Products featured in this case study

View all products (79)
Delta MS 500 Fire - Fire Retardant Studded Cavity Membrane - HDPE Type C Cavity Drainage Membrane

Delta MS 500 Fire - Fire Retardant Studded Cavity Membrane - HDPE Type C Cavity Drainage Membrane

More inspiration from Delta Membrane Systems Ltd

View inspiration
Basement Waterproofing

Basement Waterproofing

Flood Recovery – Grade II Listed Building

Flood Recovery – Grade II Listed Building

BRE Flood Reilient Test Home

BRE Flood Reilient Test Home

The Gunnery, Kent

The Gunnery, Kent

More inspiration from High-density polyethylene (PE-HD) studded sheets

View inspiration
Waterproofing the London School of Economics

Waterproofing the London School of Economics

Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing

The Schwarzman Centre

The Schwarzman Centre