NBS Source
I'm a manufacturer

Waterproofing solution to Grade II Listed Commercial Structure

OVERVIEW

The brief for this project was to design, supply and install a bespoke and sympathetic waterproofing solution to a Grade II listed, commercial structure with an impractical damp basement.


Delta Registered Installers, MacLennan Waterproofing worked closely with the Principal Contractor, HB Projects to achieve a Grade 3 habitable space whilst preserving this historic structure.


The Co-op shop in Petworth Village, provides the local community with everything they need, whether its household essentials or a place to meet friends.

The site incorporates two Listed Buildings, including part of a Listed Church. The store applied for listed building consent to reconfigure its ground and basement floors, to increase the retail floor space and improve the functionality of the store.


When designing a waterproofing/damp proofing solution in a historic building or a structure of architectural interest, additional design considerations should be employed during the design stage to maintain preserve aesthetic and structural integrity of the structure/building. The waterproofing design should be sympathetic in application whilst offering a robust solution.


Care consideration should be applied when specifying products to ensure they are ideally suited for meeting the complexities of listed building requirements.

Products featured in this case study

View all products (74)
Delta Dual V6 Package Pump Station

Delta Dual V6 Package Pump Station

Delta 800 Series Bespoke Packaged Pump Station (Groundwater)

Delta 800 Series Bespoke Packaged Pump Station (Groundwater)

Delta Dual V3 Packaged Pump Station

Delta Dual V3 Packaged Pump Station

Delta Foul V3 - Package Pump Station

Delta Foul V3 - Package Pump Station

Koster Polysil TG 500

Koster Polysil TG 500

Delta MS20 - Cavity Drainage Membrane

Delta MS20 - Cavity Drainage Membrane

More case studies from Delta Membrane Systems Ltd

View all case studies (37)
Basement Waterproofing

Basement Waterproofing

Flood Recovery – Grade II Listed Building

Flood Recovery – Grade II Listed Building

BRE Flood Reilient Test Home

BRE Flood Reilient Test Home

The Gunnery, Kent

The Gunnery, Kent

More case studies from High-density polyethylene (PE-HD) studded sheets

View all case studies (4)
Waterproofing the London School of Economics

Waterproofing the London School of Economics

Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing

Future Proofing Waterproofing Multi Level Commercial New Build Structure

Future Proofing Waterproofing Multi Level Commercial New Build Structure

More case studies from Private packaged pumping stations

View all case studies (3)
Basement Extension to a Grade 2 Listed Building, London

Basement Extension to a Grade 2 Listed Building, London

Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing

More case studies from Slip plane bituminous emulsion paint primers

View all case studies (2)
Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing