NBS Source
I'm a manufacturer

"bauder"

294 results found

Sort by:

Showing 37-72 of 88

Sponsored
BauderPIR FA G16 Tapered Insulation

BauderPIR FA G16 Tapered Insulation

Bauder Ltd

Rigid polyurethane foam board faced on both sides with aluminium foil. The top facing features a number and arrow to indicate board size and direction of fall, and also has a printed grid pattern to aid cutting on site. Thermal insulation with a low thermal conductivity to provide falls on a roof, for use within Bauder warm roof systems.
Sponsored
BauderROCK Flatboard Insulation

BauderROCK Flatboard Insulation

Bauder Ltd

BauderROCK is a dual density mineral wool insulation board with a multi-purpose facing applied to the top surface to allow waterproofing membranes to be mechanically fixed, torch-applied or adhered. The dual density composition provides a good compressive strength, whilst keeping the overall weight to a minimum. The product is non-combustible with superior acoustic performance. The underside of the board is un-faced, so bare Rock. Where more than one layer of insulation is required to hit the target U Value, an un-faced base layer is used. Only use within Bauder warm roof systems, particularly in applications where a non-combustible insulant is required or there is a demand for high noise reduction/absorption. Can be used with self-adhesive, torch-applied, adhered or mech-fixed membranes.
Sponsored
BauderROCK Tapered Insulation

BauderROCK Tapered Insulation

Bauder Ltd

BauderROCK is a dual density mineral wool insulation board with a multipurpose facing applied to the top surface to allow waterproofing membranes to be mechanically fixed, torch-applied or adhered. The dual density composition provides good compressive strength, whilst keeping the overall weight to a minimum. The product is non-combustible with superior acoustic performance. The underside of the board is un-faced, so bare Rock. Where more than one layer of insulation is required to hit the target U Value, an un-faced base layer is used. Thermal insulation to provide falls on a roof, for use within Bauder warm roof systems, where a non-combustible insulant is required or there is a demand for high noise reduction/absorption. Use with self-adhesive, torch-applied, adhered or mech-fixed membr
Sponsored
Bauder LiquiPRIME 2 - Technical Data Sheet

Bauder LiquiPRIME 2 - Technical Data Sheet

Bauder Ltd

Sponsored
Bauder K5K Roofing membrane (Charcoal Grey)

Bauder K5K Roofing membrane (Charcoal Grey)

Bauder Ltd

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation.
Sponsored
Bauder SVP Cover - Technical Data Sheet

Bauder SVP Cover - Technical Data Sheet

Bauder Ltd

Sponsored
Bauder Activator-Primer (Canister) APR01 - black

Bauder Activator-Primer (Canister) APR01 - black

Bauder Ltd

A synthetic rubber resin-based material using a non-flammable solvent and propellant system. Developed to provide the necessary preparation of substrates, insulations and underlayers prior to the installation of Self-Adhesive membranes. The product can also be used with torch-on membranes as well as a foil contact adhesive and fleece-backed membrane adhesive.
Sponsored
Cold Applied Liquid Systems - Bauder brochure

Cold Applied Liquid Systems - Bauder brochure

Bauder Ltd

Our cold applied liquid systems are based on advanced PU and PMMA technology. They are simple to install and long lasting; making them suitable for use in all kinds of flat roof and surfacing applications. Defined permutations of our cold applied liquid systems hold fire classification BROOF(t4) for compliance with building regulations under TS 1187 test method 4 for external fire exposure to roofs. LiquiTEC holds BBA Certification 14/5152 and LiquiTOP holds BBA Certification 20/5789. Fire performance is verified by the BBA and stated on the certifications.
Sponsored
Bauder K5K Roofing membrane (Grey Slate)

Bauder K5K Roofing membrane (Grey Slate)

Bauder Ltd

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation.
Sponsored
Bauder Super AL-E Roofing membrane

Bauder Super AL-E Roofing membrane

Bauder Ltd

Elastomer bitumen air & vapour control layer, torch-on membrane
Sponsored
Bauder LiquiPRIME 1 - Technical Data Sheet

Bauder LiquiPRIME 1 - Technical Data Sheet

Bauder Ltd

Sponsored
Bauder LiquiPAVE RF - Technical Data Sheet

Bauder LiquiPAVE RF - Technical Data Sheet

Bauder Ltd

Sponsored
Reinforced Bitumen Membrane Systems - Bauder brochure

Reinforced Bitumen Membrane Systems - Bauder brochure

Bauder Ltd

Our long-established and fully integrated roof systems incorporate SBS modified elastomeric bitumen membranes and highly efficient PIR insulation and holds fire classification BROOF(t4) on defined permutations for compliance with building regulations under TS 1187 test method 4 for external fire exposure to roofs and verified by the BBA and stated on our certification. All systems feature torch-free and torch-safe installation techniques for detailing on, or adjacent to combustible materials.
Sponsored
Hot Melt Structural Waterproofing - Bauder brochure

Hot Melt Structural Waterproofing - Bauder brochure

Bauder Ltd

Our hot melt roof systems are ideally suited as a waterproofing system beneath paved or ballasted surfacing, car parks, podiums, plazas, green roofs and substructures. Stated permutations of our hot melt systems hold fire classification BROOF(t4) for compliance with building regulations under TS 1187 test method 4 for external fire exposure to roofs. Fire performance is verified by the BBA and stated on our certification.
Sponsored
Refurbishment Flat Roof Solutions - Bauder brochure

Refurbishment Flat Roof Solutions - Bauder brochure

Bauder Ltd

Restoring a current flat roof; your roof could possibly be experiencing challenges that a visual appraisal may not always detect. Technical testing methods determine the scope of works required and provide graphic evidence of a roof’s condition. This information can inform decisions about how to action any defects and extend the life of your roof.
Sponsored
Single Ply Membrane Systems - Bauder brochure

Single Ply Membrane Systems - Bauder brochure

Bauder Ltd

Our single ply roofing systems are ideal for lightweight, fast track and cost effective construction projects. The systems provide solutions that are durable, resistant to the natural elements and are able to support extensive green roofs and BauderSOLAR photovoltaic arrays. All our single ply systems hold fire classification BROOF(t4) on defined permutations and verified by the BBA for compliance with building regulations under TS 1187 test method 4 for external fire exposure to roofs.
Sponsored
Bauder SA Bonding Primer - Technical Data Sheet

Bauder SA Bonding Primer - Technical Data Sheet

Bauder Ltd

Sponsored
Bauder Quick Dry Bitumen Primer - Technical Data Sheet

Bauder Quick Dry Bitumen Primer - Technical Data Sheet

Bauder Ltd

Sponsored
Bauder Fleece-Backed Membrane Adhesive - Canister - Product Data Sheet

Bauder Fleece-Backed Membrane Adhesive - Canister - Product Data Sheet

Bauder Ltd

Sponsored
Bauder EGV 35 TF Roofing membrane - Technical Data Sheet

Bauder EGV 35 TF Roofing membrane - Technical Data Sheet

Bauder Ltd

Sponsored
Bauder Parapet Emergency Overflow Stainless Steel DN 70 - Technical Data Sheet

Bauder Parapet Emergency Overflow Stainless Steel DN 70 - Technical Data Sheet

Bauder Ltd

Sponsored
BauderPLANT E Roofing membrane

BauderPLANT E Roofing membrane

Bauder Ltd

Elastomer-bitumen torch on capping sheet with root-resistance according to FLL. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture.
Sponsored
Bauder Approval Letter

Bauder Approval Letter

MSA Safety (Latchways)

Partnership Letter
Sponsored
BauderTEC KSA DUO Roofing membrane

BauderTEC KSA DUO Roofing membrane

Bauder Ltd

Elastomer bitumen self-adhesive underlayer with variable technology for lap sealing. The two side laps of the membrane have differing finishes. On one lap there is a self-adhesive finish, whist the opposite lap has a glass fleece. This allows the membrane to be sealed with either a gas torch or hot air welder.
Sponsored
BauderPLANT E 42 Roofing membrane

BauderPLANT E 42 Roofing membrane

Bauder Ltd

Elastomer-bitumen torch on capping sheet with root-resistance according to FLL. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture.
Sponsored
BauderTEC KSD Foil Roofing membrane

BauderTEC KSD Foil Roofing membrane

Bauder Ltd

Elastomer bitumen air & vapour control layer, self-adhesive membrane, for use in a warm roof flat roofing system.
Sponsored
BauderFLEX K4E Roofing membrane (Brown)

BauderFLEX K4E Roofing membrane (Brown)

Bauder Ltd

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation.
Sponsored
BauderECO FF - Technical Data Sheet

BauderECO FF - Technical Data Sheet

Bauder Ltd

Rigid foam thermoset Polyisocyanurate (PIR) board
Sponsored
BauderSYN GV 120 Glass fleece

BauderSYN GV 120 Glass fleece

Bauder Ltd

120 g/m² glass fleece to be used as a separating and fire protection layer for synthetic roofing systems. Glass fleece should be used as a lower protection fleece in cold roof assemblies between substrate and fastened unbacked PVC membrane and as an over membrane protection sheet between PVC membrane and inverted insulation boards.
Sponsored
BauderTEC KSD FBS Roofing membrane

BauderTEC KSD FBS Roofing membrane

Bauder Ltd

Elastomer bitumen air & vapour control layer, self-adhesive membrane. The lap of the membrane is equipped with a glass fleece to the underside. This allows the membrane to be sealed with either a gas torch or hot air welder. Air & Vapour Control Layer for use in a warm roof flat roofing system.
Sponsored
BauderTEC Sprint DUO Roofing membrane

BauderTEC Sprint DUO Roofing membrane

Bauder Ltd

Elastomer bitumen self-adhesive underlayer with variable technology for lap sealing. The two side laps of the membrane have differing finishes. On one lap there is a self-adhesive finish, whist the opposite lap has a glass fleece. This allows the membrane to be sealed with either a gas torch or hot air welder. Can be used adhered on a variety of appropriately prepared substrates and insulants.
Sponsored
BauderSOLAR F XL - Technical Data Sheet

BauderSOLAR F XL - Technical Data Sheet

Bauder Ltd

technical data sheet for our BauderSOLAR F XL mounting system
Sponsored
BauderTEC KSA DUO 35 Roofing membrane

BauderTEC KSA DUO 35 Roofing membrane

Bauder Ltd

Elastomer bitumen self-adhesive underlayer with variable technology for lap sealing. The two side laps of the membrane have differing finishes. On one lap there is a self-adhesive finish, whist the opposite lap has a glass fleece. This allows the membrane to be sealed with either a gas torch or hot air welder.
Sponsored
BauderFLEX K4E Roofing membrane (Grey Slate)

BauderFLEX K4E Roofing membrane (Grey Slate)

Bauder Ltd

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation.
Sponsored
BauderSYN DB-PE 100 Polyethylene AVCL

BauderSYN DB-PE 100 Polyethylene AVCL

Bauder Ltd

Polyethylene air & vapour control layer to be loose laid under BauderTHERMOFOL mechanically fastened installations.
Sponsored
BauderTHERM DS 1 DUO Roofing membrane

BauderTHERM DS 1 DUO Roofing membrane

Bauder Ltd

Elastomer bitumen air & vapour control layer, self-adhesive with variable technology for lap sealing. The two side laps of the membrane have differing finishes. On one lap there is a self-adhesive finish, whist the opposite lap has a glass fleece. This allows the membrane to be sealed with either a gas torch or hot air welder. Air & Vapour Control Layer for use in a warm roof flat roofing system. Top surface with heat-activated THERM-stripes for adhering certain insulation types.

Showing 37-72 of 88

Feedback