NBS Source
I'm a manufacturer
Compare variants

Window Trickle Ventilator THK90-AR90

Verified by manufacturer 1 month ago

THK90

Renson Fabrications Ltd Variant:

Flap vent with external hood for improved weather protection.

Jump to:
+44 (0)1622 754123 Website

Application

  • Developed for glazed-in installation, and can be integrated in aluminium, timber and PVC window profiles.
  • Installed at transom using an additional transom profile.

Description

AR90 and THK90 are flap vents with an external hood for improved weather protection. The AR90 is the self-regulating version of the THK90. A self-regulating flap is integrated, reacting automatically to various wind pressures and thus preventing draughts. The non self-regulating THK90 has a flat interior profile, which makes it a good solution for the integration in the fixed part of sash windows.


Features and benefits:

  • Developed for glazed-in installation.
  • Thermally broken - no cold air can transfer from outside to inside.
  • External hood for additional weather protection.
  • AR90 ensures the supply of fresh and healthy air without draughts with its self-regulating flap.
  • Flat interior profile.
  • The perforated inside profile acts as an insect mesh.

General information

Color

Other

Finish

Powder-coated

Material

Aluminium

Shape

Other

Uniclass

Pr_30_59_57_58 Overhead ventilatorsPrimary

CAWS

L10/400 Composite windows

L10/33 Proprietary windows

L10/31 PVC-U windows

L10/30 PVC-U windows

L10/25 Aluminium windows

L10/20 Steel windows

L10/10 Wood windows

L10/15 Wood windows

L10/390 Proprietary windows

L10/350 PVC-U windows

L10/330 Aluminium windows

L10/310 Steel windows

L10/210 Wood windows

H11/110 Curtain walling

Product range

Window Ventilators / Glazed-In Ventilators

Specification data - Overhead ventilators

Installation type

Glazed-in.

At transom.

Thermal performance

Thermally broken.

Acoustic performance

28 (-1;-3) dB (open).
44 (-1;-3) dB (closed).

Watertightness

Up to 650 Pa (closed position).
Up to 50 Pa (open position).

Wind resistance (minimum)

Guidance for specification option:

Consult manufacturer for details and insert requirements.

Ventilation rate (minimum)

16.1 l/s/m at 2 Pa.

Design aperture

-

Height

105 mm.

Length

Guidance for specification option:

Insert requirements:

  • Maximum length: 2500 mm.
  • 2000 mm for motorised control.

Finish

Polyester powder coating.

Colour

RAL colour.

Guidance for specification option:

Consult manufacturer and insert requirements.

Operation

Manual.

Cord.

Rod.

Motor.

Accessories

Non-self regulating ventilation flap.

U-value

3.9 W/m²K.

Air leakage

<15% (in closed position) at 50 Pa.

Glass thickness

20 mm.

24 mm.

28 mm.

Sustainability data

Material

Aluminium