Enhanced EPS 70E
KIWA BDA
Certificate type
A framed KIWA BDA certified system consisting of a Enhanced EPS insulation board, basecoated, meshed, finished off with brick slip finish.
Suitable for use on the outside of steel or timber frame walls of new or existing domestic and non-domestic buildings, with height and boundary restrictions (see systems KIWA certificate for further information).
A KIWA BDA certified system consisting of either vertical timber battens or cavity spacer rails, Enhanced EPS insulation board, basecoated, meshed, finished off with brick slip finish. A second option of stone slips which incorporate a stainless-steel mesh for the system.
Features and benefits:
Preparation:
Uniclass | |
CAWS | M21/20 External wall insulation system . . . . . . M21/210 External wall insulation system |
System performance | Thermal Performance.The systems can improve the thermal performance of external walls and can contribute to satisfying the requirements of the National Building Regulations. Strength and Stability.The systems has adequate strength and is designed to adequately resist impact damage and wind loads encountered in the UK. When the system incorporates a stone slip finish, the system can only be applied at ground and first floor level (maximum 6 m in height). System Tested to BS EN 13501-1.Achieves a value of B-s1, d0 reaction to fire classification. Risk of Condensation.The system can contribute to a limiting risk of interstitial and surface condensation. Durability.When installed and maintained in accordance with the Certificate holders recommendations and this Certificate, the system will remain effective for at least 30 years. Further Information.For further information on the above points visit the system KIWA BDA Certificate. |
Support rails and brackets | - |
Material
| 15mm RagRail Cavity Spacer Rails.
25mm RagRail Cavity Spacer Rails.
25mm Timber Battens.
|
Bracket fixings
| LS 5.5 (steel frame).R-QCP (timber frame). |
Base boards | - |
Material | Framed substrate sheathed using Wetherby approved sheathing board.The framed substrate must be sheathed using a Wetherby approved sheathing board ensuring that they achieve minimum pull out requirements to be suitable for the systems application. |
Fixings | Fix boards in accordance with site conditions and manufacturer instructions. |
Insulation | - |
Material | Enhanced EPS 70E. |
Fixings
| TKR Screw Range.R-QCP Screw Range. |
Fire barriers and stops | - |
Material | Stone Wool/ Horizontal Lamella Fire Barriers.
Stone Wool/ Vertical Lamella Fire Barriers.Mechanically and adhesively fix fire breaks vertically direct back to the sheathing board at agreed locations and at a rate of four stainless steel fixings per board minimum. Tenmat Intumescent Strip.
|
Fixings | TKE Range – Steel Frame.Typically used to fix fire barrier and intumescent strips to their agreed locations (Rail/ Sheathing Board/ Steel Frame). R-UCF Range - TImber Frame.Typically used to fix fire barriers to their agreed locations (Timber Batten / Sheathing Board/ Timber Frame). |
Beads and trims | Not required.Deflector beads. |
Movement joints | - |
Form with
| WBS Stainless Steel Movement Joints.WBS PVC Movement Joints.WBS Stainless Steel Surface Mounted Render Stop Beads.WBS PVC Surface Mounted Render Stop Beads. |
Sealant | Compriband sealing tape must be installed between the insulation boards. |
Render carrier or reinforcement | - |
Material | WBS Alkali-resistant scrim cloth incorporated into scrim adhesive.Stainless Steel Brick Mesh applied over first pass of scrim adhesive. |
Mesh size | Alkali Resistant Mesh 50 m² (roll).Stainless Steel Brick Mesh – 1195 x 819 mm.Stainless Steel Stone Slip Mesh – 1195 x 819 mm. |
Fixings
| TKE screw range.Combined with the relevant cap/ washer this fixing is typically used for the main fixings installed through the mesh Normally specified when fixing into the RagRail/ Cavity Spacer Rail. R-UCF screw range.Combined with the relevant cap/ washer this fixing is typically used for the main fixings installed through the mesh. Only specified specify when fixing into the timber batten. |
Render | - |
Material | Brick Slip Adhesive.
WBS 9-25mm Brick Slips.
WBS Pointing Mortar.
|
Decorative finish | - |
ColourSee brick slip brochure and insert requirement. | - |
System accessories | WBS Sealing Tape: Pre-compressed, expanding waterproof sealing tape.WBS Firtree Fixings.WBS Jointing Pieces.WBS End Caps.WBS EVO-STIK Silicone Sealant.WBS APU Bead.Roof verge extenders.Under and over cills.Cill extenders.End stop profiles.Insert requirement: Available in stainless steel, PVC-U or organic polyester powder-coated galvanized steel. Corner mesh profiles.Insert requirement: Available in stainless steel, PVC-U or organic polyester powder-coated galvanized steel. Expansion joint profiles.Insert requirement: Available in stainless steel, PVC-U or organic polyester powder-coated galvanized steel. |
Samples required | Approved samples required.
|
Execution | Install system as per manufacturer’s instructions.
|
System completion | Inspection, documentation, O&M manuals and data sheets.
|
Third-party certification | NHBC. |
Dimensions | 1200 x 600 mm. |
Density | 15 kg/m³. |
CompressiveStrengthTo BS EN 13163. | 70 kN/m² (minimum). At 10% deformation. |
ThermalConductivity | 0.032 W/m·K. To BS EN 13163. |
Reaction to fire classification | Class B-s1, d0 to BS EN 13501-1: 2002.
Class E to BS EN 13501-1: 2002. EPS. |
SurfaceSpreadOfFlame | Flame Retardant Grade. |
Environmental performance | CFC/ HCFC Free. |
Ozone depleting potential (ODP) | Zero. |
Global warming potential (GWP) | Less than 5. |
Board thickness | 50–240 mm. Thicknesses compatible with the system certification range between 50–240 mm; insert requirement. |