Saint-Gobain Weber

Render protected, mechanically fixed external wall insulation (EWI) system, based on mineral fibre (MF) insulation and a weberplast TF top coat.

Jump to:
+44 (0)1525 718877 www.uk.weber
Application

Suitable for use in refurbishment and new build projects. Can be used above 18 m in England and Wales, and above 11 m for Scotland to comply with appropriate Building Regulations.

Description

Render protected, mechanically fixed external wall insulation (EWI) system, based on mineral fibre (MF) insulation with a meshcloth reinforced basecoat, a top coat and a synthetic finish.

Features and benefits:

  • Chlorofluorocarbon (CFC)/ hydrochlorofluorocarbon (HCFC) free.
  • Good impact resistance.
  • Provides weather protection.
  • Lightweight.
  • A wide range of finish coat colours are available.
  • Can be used for decorating and re-modelling existing facades.
  • BBA approved.
  • When installed to a masonry substrate and maintained in accordance with the manufacturer's recommendations, the system will remain effective for at least 30 years. The durability can be extended to 60 years by using specific fixings, accessories, additional adhesive and by following a planned inspection and maintenance schedule. Consult manufacturer for details.

Applications:

Suitable for use in refurbishment and new build projects. Can be used above 18 m in England and Wales, and above 11 m for Scotland to comply with appropriate Building Regulations.

System components:

  • Weber fixings as specified for the substrate.
  • webertherm MFD insulation (of specified thickness).
  • weberend LAC (first layer, 3 mm).
  • weber standard meshcloth.
  • weberend LAC (second layer, 3 mm).
  • weber PR310 primer.
  • weberplast TF Silver Pearl.

The installation must be capable of resisting all dead loads and design live loads, including impact and wind loads, and accommodate all thermal movements without damage.

System installation is to be strictly in accordance with Saint-Gobain Weber specification. Please note that any other manufacturer's products used within the system will invalidate the guarantee, and the performance cannot be supported.

Remedial work must be completed prior to the installation of Weber EWI Systems.

Recommendations:

  • It is recommended for the contractors/ clients design team to ensure the system installed meets the building regulations requirements along with undertaking design liability for the building in its entirety including compliance with supplementary guidance such as BR 135. Weber external wall insulation systems incorporating mineral fibre insulation with a suitable fire tested finish (contact Weber for further details) achieve a reaction to fire classification of A2, s1, d0. Systems achieving this classification or better are considered suitable for use on, or at any distance from, a boundary without height restriction. In addition to the main wall fixings, appropriate fire fixings (stainless steel as per BRE 135) should also be installed at a rate of 1/m² minimum across the whole area receiving the system.
  • Fixings must penetrate the structure in accordance with the fixing design to provide the appropriate pull out resistance. A survey of the building must be completed by an engineer to ensure the additional load does not have a detrimental effect on the building and the fixings are able to sufficiently penetrate the structure, to adequately support the Weber system. Weber will undertake fixing pull out tests and verify the adequacy of the fixing design based on a wind loading assessment carried out in accordance with BS EN 1991-1-4: 2005.

General information
Specification data - Adhesive-fixed external wall insulation systems
Product Reference

webertherm XM FM218

For new, sound brick/ block or existing rendered/ un-rendered sound masonry substrates.

webertherm XM FM218P

For heavy duty fibre cement sheathing or suitable alternative recommended boards/ panels.

Building height

Insert requirements.

Preparation

Not required

Weber CL150 Fungicidal Masonry Wash

Consult manufacturer for details.

Insulation -
Type

webertherm MFD Mineral Fibre Dual Density

Euro Class A1.

Thickness

Dependent on required thermal transmittance (U-Value). Consult manufacturer and insert requirement.

Fixings

To be confirmed on-site by pull out tests in accordance with BS EN 1991-1-4: 2005

Recycled content

Consult manufacturer for details and insert requirements.

Glass fibre reinforcement

webermesh standard

Balanced, open weave glass fibre meshcloth, coated for alkaline resistance. 1 x 50 m roll.

Adhesive

Required to comply with SWIGA guarantee requirements on all buildings greater than four floors in height above ground level. Consult manufacturer and insert requirements.

Cavity barriers

Type, thickness, density and compressive strength to be determined by the design team

Consult manufacturer for details.

Sealant joints

Low modulus silicone

Consult manufacturer for details.

Render -
First coat

weberend LAC

Standard. Uncoloured, polymer modified render, comprising FS2 sand, lime, cement, fillers and dry polymer.

weberend LAC rapid

To increase the speed of installation; consult manufacturer for details.

Finishing coat -
Primer

weber PR310

Low viscosity liquid (not required for weberend LAC rapid).

Type

weberplast TF

Standard. 1.5 mm silicone based, factory batched textured finish. Water repellent, vapour permeable, weather resistant and UV stable.

weberend mineral TF

To increase the speed of installation; consult manufacturer for details.

Colour

Consult manufacturer's colour chart and insert requirements.

Thickness

7.5 mm (minimum). Consult manufacturer and insert requirements.

Accessories/ Other requirements

See 'Options' and insert requirements.

Standard product features

Fire classification (to BS EN 13501-1):

A2, s1, d0.

Impact resistance (to ETAG 004):

Category ii.

Coverage:

  • webertherm MFD: 0.72 m² per board.
  • weberend LAC: 6.5 kg/m².
  • webermesh standard: 45 m² per roll.
  • weber PR310: 0.25 L/m².
  • weberplast TF: 2.8 kg/m².

Product Options

Preparation:

- Weber CL150 Fungicidal Masonry Wash:

For existing substrates, or where required on new substrates, drench apply CL150 wash and leave for 48 hours, then brush down to remove all moss/ growth.

Insulation:

  • Mineral wool insulation is non-combustible and is good at absorbing acoustics where noise pollution may be an issue.
  • Size: 1200 x 600 mm.
  • Thickness: 30–200 mm available.
  • Nominal density: First 15 mm: 160 kg/m³; balance: 100 kg/m³.
  • Thermal conductivity: 0.036 W/m·K.
  • Vapour resistivity: ≥5.9 MNs/gm.
  • Fire classification: Euroclass A1 when tested to BS EN 13501-1.
  • Fixings: Two required per insulation board.

Render:

- First coat:

To be applied in two coats, incorporating meshcloth insulation board. Apply 2–3 mm thick, incorporating weber meshcloth. Allow for partial take-up then apply further 3 mm to form a nominal 6 mm thick monolithic coat.

- Final coat:

  • Can be applied with a thin plastic float.
  • Primer: Can be brush, spray, or roller applied.

Accessories/ Other requirements:

Full system and render only beads, if required by the system or product, or if specified, shall be of appropriate design, gauge and material (aluminium/ polyvinyl chloride (PVC)/ stainless steel) - consult manufacturer for details. Some available accessories are listed below:

  • Clip on nose beads.
  • Compressible sealing tape.
  • Fire barriers: Consult manufacturer for details.
  • Full system Weber base bead: Aluminium box profile with clip on nosing.
  • Overcills.
  • Render-only drip/ corner beads.
  • Undercills.
  • Verge flashing.
  • Weber frame seal – Can be used as an alternative at windows to provide a mastic free seal with improved aesthetics/ maintenance.
  • Weber pre-coated, pressed aluminium under cill trims: 1.2 mm thick (nominal), size to suit EWI System, if required.
  • Weber pre-coated, pressed aluminium verge trims: 1.2 mm thick (nominal), size to suit EWI System, if required.
  • Weber PVC corner, stop, drip and movement beads: As required.
  • Z flashing.

Literature
Third party certifications

Additional certifications:

  • NSAI: Certificate: 06/0260 and 09/0338
Similar products from Saint-Gobain Weber