NBS Source
I'm a manufacturer

webercem spray RS - Dry-sprayed Concrete

Verified by manufacturer today

Saint-Gobain Weber Third party certifications:
  • ISO 14001 Environmental Management Systems

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

Rapid-setting dry spray structural repair concrete

Jump to:
+44 (0)1525 718877 Website

Application

  • Rapid repairs to structures within tidal zones.
  • Repairs to dock walls.
  • Repairs to coastal structures.
  • Structural repairs to jetties, piers, sea walls, quays and docks.
  • Repairs to river bridge abutments or piers.
  • Primary linings to underground workings.
  • Structural repairs to concrete beams, columns and soffits.
  • Repairs to railway bridge and viaduct soffits.


Description

Rapid-setting dry spray structural repair concrete designed to give high strength, low rebound, low wastage and to maxmise application thickness.


Containing graded inert limestone aggregates and dust suppressants, webercem spray RS has conformity testing to BS EN 1504-3 and meets the requirements for a Class R4 repair product. 


Features and benefits:

  • Rapid setting concrete allows work to continue in tidal zones.
  • Rapid set prevents wash out from tidal action or flowing water.
  • Economical with low rebound.
  • High-build – up to 150 mm thickness can be applied in one pass to vertical faces.
  • Good adhesion to concrete substrates.
  • Non reactive aggregate complying with HA Clause 1704.
  • Total chloride ion content is less than 0.05%. No calcium chloride or admixtures containing chloride salts are used.
  • Good resistance to salts absorption.

General information

Material

Concrete

Shape

Formless

Material

Concrete

Uniclass

Pr_20_31_16_66 Pre-blended concretesPrimary

CAWS

C42/325 Proprietary sprayed mortar/ concrete

Specification data - Pre-blended concretes

CompressiveStrength

>45 MPa.

Chloride Ion content

0.01%.

Adhesive bond

2.2 MPa.

Carbonation resistance

Pass.

Modulus of elasticity

28.5 GPa.

Capillary absorption

0.37 kgm-²h-0.5.

Freeze/ Thaw Resistance

Bond 2.2 MPa.

Chloride ion resistance

Control 0.023% no immersion. Test 0.029% at 10 mm depth
after 6 months.

Standard

To BS EN 1504-3.

Mortar type

Polymer modified.

Performance requirement class

R3.

R4.

Sustainability data

Material

Concrete

Third party certifications

ISO 14001 Environmental Management Systems

ISO 14001:2015

ISO 45001 Health and Safety Management

ISO 45001:2018

ISO 9001 Quality Management

ISO 9001:2015

Literature

webercem spray RS - Technical datasheet

webercem spray RS - Technical datasheet

Inspiration Guide

Inspiration Guide

Solutions for construction - Introducing Weber

Solutions for construction - Introducing Weber

Marine Infrastructure Guide

Marine Infrastructure Guide

Weber Concrete Repair and Protection

Weber Concrete Repair and Protection

Similar products from Saint-Gobain Weber

webercem pyracrete - Bedding Concrete.

webercem pyrapatch - Repair Concrete

webercem spray CP

webercem spray CP

webercem spray DS

webercem spray DS

webercem spray DSF - Repair Mortar

webercem spray RSF - Dry-sprayed Concrete.