NBS Source
I'm a manufacturer
Compare variants

Vieo Warm Wall TD - Insulated Standing Seam Wall System

Verified by manufacturer 1 day ago

EC 25-454 Vieo aluminium external profiles

Euroclad Group Ltd Variant:

Interlocking steel or aluminium sheets that can be used as part of an exterior wall construction.

Jump to:
+44 (0)2922 010101 Website

Application

Designed for use with a suitable continuous substrate such as 18 mm plywood or 15 mm OSB board to support the RocSlab and a VCL located at the warm side of the insulation.

Suitable for a wide range of building applications, suitable for use with residential, commercial and public buildings.

Description

Interlocking steel or aluminium sheets that can be used as part of an exterior wall construction. Vieo warm systems are characterized by the thermal insulation being immediately beneath the Vieo sheets.

Designed for use with a suitable continuous substrate such as 18 mm plywood or 15 mm OSB board to support the RocSlab and a VCL located at the warm side of the insulation.

Warm wall: where the principal thermal insulation layer is placed immediately inside the outer profiled sheeting, resulting in the supporting structure and any voids being at a temperature close to that of the interior of the building.

Features and benefits:

  • Vieo systems are available in straight, curved and tapered sheet options, enabling creation of creative architectural forms.
  • Vieo sheets are available in variable widths allowing for feature band design.
  • Vieo wall sheets can be installed vertically or horizontally as standard.
  • Simple, guaranteed alternative to traditional systems.
  • Can be applied to roof and walls (roofs specified separately).
  • Hidden fixings for a clean, attractive finish.
  • Fast construction aided by the pre-punched Euroclad RocBar.
  • Factory manufactured or produced on-site using specialist mobile equipment.
  • Can be used to contribute to Passivhaus standards.
  • Available in straight, curved and tapered sheet options.
  • Euroclad RocSlab insulation is quickly laid. Vieo sheets and RocSlab, when installed, are suitable for access for maintenance and repair.
  • Measured acoustic performances can be obtained through consultation with the manufacturer’s Technical Department.
  • External steel sheet available in a range of coatings and colours.

Matching roof systems and cold wall systems and also available, specified separately.

General information

Color

Gold

Grey

Black

Blue

Red

Finish

Coated

Matt

Textured

Smooth

PVdF

Material

Steel

Aluminium

Mineral wool

Shape

Other

Guidance for specification option:

Sinusoidal.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Guidance for specification option:

A Vieo system guarantee is available for up to 25 years; consult manufacturer for details.

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting cladding systems

System performance

Guidance for specification option:

Insert requirements.

Manufacturer guidance

Reaction to fire to BS EN 13501-1:2018 (inc. BS EN ISO 11925-2:2020 + BS EN 13823:2020):

Classification on component basis only, see individual component guidance or consult manufacturer for details.

Air and vapour control layer

-

Material

Euroclad B VCL.
Euroclad A2 VCL.

Fasteners

Manufacturer's standard.

Sealing

Euroclad VCL Sealing Tape.
Euroclad A2 VCL Sealing Tape.

Spacers

Euroclad RocBar.

Manufacturer guidance

RocSlab25 insulation between bars; see Thermal insulation.

Acoustic insulation

Not applicable.

Thermal insulation

RocSlab 50 mm and RocSlab25.

Guidance for specification option:

System depth: 104.1 mm.

System weight: 17.88 kg/m².

U-value from calculation: NPD.

RocSlab 50 mm + 50 mm and RocSlab25.

Guidance for specification option:

System depth: 154.1 mm.

System weight: 24.94 kg/m².

U-value from calculation: NPD.

RocSlab 115 mm and RocSlab25.

Guidance for specification option:

System depth: 169.1 mm.

System weight: 24.97 kg/m².

U-value from calculation: 0.25 W/m²K.

RocSlab 150 mm and RocSlab25.

Guidance for specification option:

System depth: 204.1 mm.

System weight: 29.29 kg/m².

U-value from calculation: 0.20 W/m²K.

RocSlab 50 mm + 115 mm and RocSlab25.

Guidance for specification option:

System depth: 219.1 mm.

System weight: 32.02 kg/m².

U-value from calculation: 0.18 W/m²K.

RocSlab 170 mm and RocSlab25.

Guidance for specification option:

System depth: 224.1 mm.

System weight: 31.73 kg/m².

U-value from calculation: 0.18 W/m²K.

RocSlab 50 mm + 150 mm and RocSlab25.

Guidance for specification option:

System depth: 254.1 mm.

System weight: 36.29 kg/m².

U-value from calculation: 0.18 W/m²K.

RocSlab 205 mm and RocSlab25.

Guidance for specification option:

System depth: 259.1 mm.

System weight: 36.04 kg/m².

U-value from calculation: 0.16 W/m²K.

RocSlab 50 mm + 170 mm and RocSlab25.

Guidance for specification option:

System depth: 274.1 mm.

System weight: 38.77 kg/m².

U-value from calculation: 0.15 W/m²K.

RocSlab 115 mm + 115 mm and RocSlab25.

Guidance for specification option:

System depth: 284.1 mm.

System weight: 39.09 kg/m².

U-value from calculation: 0.14 W/m²K.

RocSlab 50 mm + 205 mm and RocSlab25.

Guidance for specification option:

System depth: 309.1 mm.

System weight: 43.08 kg/m².

U-value from calculation: 0.14 W/m²K.

RocSlab 115 mm + 150 mm and RocSlab25.

Guidance for specification option:

System depth: 319.1 mm.

System weight: 43.40 kg/m².

U-value from calculation: 0.13 W/m²K.

RocSlab 115 mm + 170 mm and RocSlab25.

Guidance for specification option:

System depth: 339.1 mm.

System weight: 45.85 kg/m².

U-value from calculation: 0.12 W/m²K.

RocSlab 150 mm + 150 mm and RocSlab25.

Guidance for specification option:

System depth: 354.1 mm.

System weight: 47.79 kg/m².

U-value from calculation: 0.11 W/m²K.

RocSlab 150 mm + 170 mm and RocSlab25.

Guidance for specification option:

System depth: 374.1 mm.

System weight: 50.23 kg/m².

U-value from calculation: 0.10 W/m²K.

RocSlab 115 mm + 205 mm and RocSlab25.

Guidance for specification option:

System depth: 374.1 mm.

System weight: 50.23 kg/m².

U-value from calculation: 0.10 W/m²K.

RocSlab 170 mm + 170 mm and RocSlab25.

Guidance for specification option:

System depth: 394.1 mm.

System weight: 52.85 kg/m².

U-value from calculation: 0.10 W/m²K.

RocSlab 150 mm + 205 mm and RocSlab25.

Guidance for specification option:

System depth: 409.1 mm.

System weight: 54.69 kg/m².

U-value from calculation: 0.09 W/m²K.

RocSlab 170 mm + 205 mm and RocSlab25.

Guidance for specification option:

System depth: 429.1 mm.

System weight: 57.13 kg/m².

U-value from calculation: 0.09 W/m²K.

Manufacturer guidance

Insulation lambda claim - thermal: 0.036 W/m·K.

25 mm-thick RocSlab between RocBars.

External sheets

-

Material

0.90 mm 3105 aluminium alloy.
0.90 mm 3004 aluminium alloy.

Primary fasteners

Stainless steel fixings (Vieo sliding clips and Vieo clip fixings); plastic tubes.

Guidance for specification option:

  • Vieo sliding clips are for attachment of Vieo sheets; Vieo clip fixings are for attachment of Vieo sliding clips to various substrates.
  • Both are Class A1 to BS EN 13501-1:2018.

End and side laps

Vieo Closures.

Guidance for specification option:

For completion of detailing and ends and edges of Vieo sheets.

Aluminium, Class A1 to BS EN 13501-1:2018.

System accessories

Euroclad Separation Tape.
None.

Colour/ Finish

Arconic PVDF.

Guidance for specification option:

  • To BS EN 13501-1:2018: A1 (RA22-0049).
  • To BS EN 13501-5:2016: BROOF(T4) (Commission Decision 2000/553/EC).

Arconic Polyester Polyamide (ARS).

Guidance for specification option:

  • To BS EN 13501-1:2018: A1 (RA21-0210).
  • To BS EN 13501-5:2016: BROOF(T4) (Commission Decision 2000/553/EC).

Arconic Duragloss 5000.

Guidance for specification option:

  • To BS EN 13501-1:2018: A1 (RA21-0210).
  • To BS EN 13501-5:2016: BROOF(T4) (Commission Decision 2000/553/EC).

System depth

Manufacturer's standard.

Guidance for specification option:

Dependent on insulation thickness; see Thermal insulation guidance for details.

Weight

Manufacturer's standard.

Guidance for specification option:

Dependent on insulation thickness; see Thermal insulation guidance for details.

Orientation

Vertical.

Horizontal.

Sheet width

Cover width: 454 mm.

Guidance for specification option:

As standard.

Can also be supplied in variable widths to give a concertina-style effect (on request).

Sustainability data

Material

Steel
Aluminium
Mineral wool

Similar products from Euroclad Group Ltd

Elite 50 Range - Wall System

Elite 50 Range - Wall System

Elite 51 Range - Wall System

Elite 51 Range - Wall System

Elite 52 Range - Wall System

Elite 52 Range - Wall System

Elite 53 Range - Wall System

Elite 53 Range - Wall System

Elite 54 Range - Wall System

Elite 54 Range - Wall System

Elite 55 Range - Wall System

Elite 55 Range - Wall System

Elite 56 Range - Wall System

Elite 56 Range - Wall System

Elite 57 Range - Wall System

Elite 57 Range - Wall System

Elite 58 Range - Wall System

Elite 58 Range - Wall System

Elite 60 Range - Wall System

Elite 60 Range - Wall System