Vertical fire curtain certified to 90 minutes integrity and radiation rating.

Jump to:
0151 422 9111 Website

Application

Suited to many different applications; some of the most common are to:

  • Compartmentalise open-plan sections in a room or space.
  • Cover exit routes within wide corridors.
  • Cover openings in walls e.g. serving hatches.
  • Cover non-fire-rated doors or glazing.
  • Cover lifts and lift shafts that can act as fire or smoke chutes.
  • Protect escape routes.
  • Provide boundary protection.

Description

The Adexon-FC90EW is a multi-purpose fire curtain offering integrity (E) and radiation (W) performance. Designed to limit and control the spread of fire for 90 minutes at over 1000°C, and also reduce the radiation of heat from one side of the curtain to the other for 90 minutes. Smoke sealing is also available to limit and control the spread of smoke created by a fire.


Features and benefits:

  • The system is tested and certified to BS EN 16034:2014, with smoke control tested to BS EN 1634-3:2004.
  • Operation is via 24 V d.c. tubular motors controlled by an electronic control board.
  • It has gravity fail-safe to ensure that the system will deploy to its fire-operational position, so that protection is provided irrespective of whether power is maintained or not.
  • Standard lead time is between 6 to 10 weeks from approval of drawings.
  • Optional extras such as emergency retract buttons and obstruction warning are available upon request.

General information

Color

Other

Finish

Galvanized

Powder-coated

Material

Steel

Fiber-glass

Polyurethane

Shape

Rectangle

Width

Bespoke

7000 mm

12000 mm

Manufacturer guidance

Curtain maximum dimensions: 12 x 4.5 m or 7 x 8 m (width x height).

Height

Bespoke

4500 mm

8000 mm

Uniclass

Pr_25_80_79_94 Vertical active fire curtain barriersPrimary

CAWS

L20/610 Roller shutters/ curtains

Specification data - Vertical active fire curtain barriers

Standards

-

Barrier assemblies

CE marked to BS EN 16034.

Test standards

Safety and performance to BS EN 16034, fire resistance to BS EN 1634-1 in accordance with BS EN 13501-2.

Third-party certification

Applus+ Certificate 0370-CPR-6418.

Size

Guidance for specification option:

  • Curtain maximum dimensions: 12 x 4.5 m or 7 x 8 m (width x height). Insert requirements or refer to a drawing.
  • Determine project requirements on a curtain-by-curtain basis through detailed design and scheduling. Refer to drawings for locations.

Performance

-

Durability class

C1.

Smoke containment

Not required.

To BS EN 1634-3:2004.

Guidance for specification option:

Recommended option. Refer to manufacturer's literature for smoke control curtain sizes.

Fire resistance

EW90.

Barrier units

Single.

Multiple.

Activation

Fire alarm signal.

Signal from local smoke or heat detector.

BMS.

Accessories

None.

Emergency retract buttons.

Obstruction warning.

Colour/ Finish

Galvanized.

Galvanized and powder-coated.

Guidance for specification option:

All standard and non-standard PPC colours are available. Insert requirements.

Bottom bar

Standard bar.

Wide/ flat bottom bar.

T-bar.

Third party certifications

Certificate of constancy of performance

Certificate of constancy of performance

FC90EW Certificate

Literature

FC90EW Brochure

FC90EW Brochure

FC90EW Drawing

FC90EW Drawing

FC90EW Uniclass Spec

FC90EW Uniclass Spec

Similar products from Adexon Fire & Smoke Curtains

Concertina Fire Curtain - 120 min - CFC120E - Fire Curtain

Concertina Fire Curtain - 120 min - CFC120E - Fire Curtain

Vertical Fire Curtain - 120 min + Radiation - FC120EW - Fire Curtain

Vertical Fire Curtain - 120 min + Radiation - FC120EW - Fire Curtain

Vertical Fire Curtain - 120 min - FC120E - Fire Curtain

Vertical Fire Curtain - 120 min - FC120E - Fire Curtain

Vertical Fire Curtain - 180 min + Insulation - FC180EI - Fire Curtain

Vertical Fire Curtain - 180 min + Insulation - FC180EI - Fire Curtain

Vertical Fire Curtain - 60 min + Radiation - FC60EW - Fire Curtain

Vertical Fire Curtain - 60 min + Radiation - FC60EW - Fire Curtain