This site uses cookies to store information on your computer. Learn more about these cookies, and how to opt out of them. Find out more

NBS Source

Application

Suitable for use on a range of construction projects.

Description

Unity A2 FP (folded plank) Aluminium Rainscreen cladding system comprising 3 mm thick aluminium panels carried by the Clad-Line CL1 aluminium support structure. The system is fixed to an inner leaf structural wall and other components such as insulant, membranes, breakers are incorporated. The system is drained and back-ventilated.

            

Approved, trained, and certified design/installation contractors to install the system and components.

General information

Finish

Powder-coated

Material

Aluminium

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Developed and manufactured in accordance with CWCT guidelines.

Thermal insulation

Insert requirements.

-

Breather membrane

-

Material

Insert requirements.

-

Secondary support structure

To EN 755, extruded aluminium, 6063/T6 grade alloy.

CLAD-LINE CL1 Sub-Frame System.

Aluminium support system comprising extruded vertical support rails (T/L profiled rails) with adjustable wall attachment brackets to suit cladding zone.


CLAD-LINE’s T and L profiled rails are fixed using the CL range of support brackets which provide up to 30 mm adjustment of the rail face. Fixed Point (dead load) brackets are designed to absorb vertical dead loads while the Sliding Point brackets allow for expansion and contraction and are designed to absorb wind loads.

CLAD-LINE F2F (Floor to Floor) Sub-Frame System.

Floor to floor spanning support system comprising an extruded vertical sheeting rail (Rail Type 1–2 mm face, Rail Type 2–4 mm face), a Primary Angle Bracket, a BS Link Bracket (allowing for up to 30 degree rotation), Link Bracket Fixing Assemblies, a Fixed Point Clip and a Sliding Point Clip (if required).

Cavity fire barriers

-

Horizontal

Insert requirements.

-

Vertical

Insert requirements.

-

Cladding panels

-

Material

Aluminium folded plank panels.

Panel joints

Open joints.

Samples required

None.

Panel and finish samples.

Samples of fixings.

Fabrication samples.

Mock-up to validate details.

Finish

Polyester powder-coated.

60 Microns. A2-s1, d0 classification to EN 13501-1.

Colour

Extensive range of colours. Consult manufacturer and insert requirements.

-

Thickness

3 mm.

Joint width

Insert requirements, 10–20 mm.

-

Sheeting rails

Continous rails.

Individual rails.

Rail material/ finish

To EN 755, extruded aluminium, 6063/T6 grade alloy.

Environmental information

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

100

Recycled content

65 %

Literature

UNITY A2 FP-T01 VERTICAL JOINT Technical Drawing

UNITY A2 FP-T01 VERTICAL JOINT Technical Drawing

UNITY A2 FP-T02 HORIZONTAL JOINT Technical Drawing

UNITY A2 FP-T02 HORIZONTAL JOINT Technical Drawing

UNITY A2 FP-T03 SOFFIT RETURN Technical Drawing

UNITY A2 FP-T03 SOFFIT RETURN Technical Drawing

UNITY A2 FP-T04 EXTERNAL CORNER Technical Drawing

UNITY A2 FP-T04 EXTERNAL CORNER Technical Drawing

UNITY A2 FP-T05 INTERNAL CORNER Technical Drawing

UNITY A2 FP-T05 INTERNAL CORNER Technical Drawing

UNITY A2 FP-T06 CILL INTERFACE Technical Drawing

UNITY A2 FP-T06 CILL INTERFACE Technical Drawing

UNITY A2 FP-T07 GLAZING HEAD INTERFACE Technical Drawing

UNITY A2 FP-T07 GLAZING HEAD INTERFACE Technical Drawing

UNITY A2 FP-T08 CAPPING INTERFACE Technical Drawing

UNITY A2 FP-T08 CAPPING INTERFACE Technical Drawing

UNITY A2 FP-T09 JAMB INTERFACE Technical Drawing

UNITY A2 FP-T09 JAMB INTERFACE Technical Drawing

Similar products from Metalline Architectural Fabrications

Unity A1 FP (folded plank) Aluminium Rainscreen

Unity A1 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A1 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A1DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity A1PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity A1SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1TF (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

Unity A1TF (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

Unity A2 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A2 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A2DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding