This site uses cookies to store information on your computer. Learn more about these cookies, and how to opt out of them. Find out more
Verified by manufacturer 5 months ago
A folded plank aluminium rainscreen cladding system.
Suitable for use on a range of construction projects.
Unity A2 FP (folded plank) Aluminium Rainscreen cladding system comprising 3 mm thick aluminium panels carried by the Clad-Line CL1 aluminium support structure. The system is fixed to an inner leaf structural wall and other components such as insulant, membranes, breakers are incorporated. The system is drained and back-ventilated.
Approved, trained, and certified design/installation contractors to install the system and components.
Finish | Powder-coated |
Material | Aluminium |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
System performance | Developed and manufactured in accordance with CWCT guidelines. |
Thermal insulationInsert requirements. | - |
Breather membrane | - |
MaterialInsert requirements. | - |
Secondary support structureTo EN 755, extruded aluminium, 6063/T6 grade alloy. | CLAD-LINE CL1 Sub-Frame System.Aluminium support system comprising extruded vertical support rails (T/L profiled rails) with adjustable wall attachment brackets to suit cladding zone. CLAD-LINE’s T and L profiled rails are fixed using the CL range of support brackets which provide up to 30 mm adjustment of the rail face. Fixed Point (dead load) brackets are designed to absorb vertical dead loads while the Sliding Point brackets allow for expansion and contraction and are designed to absorb wind loads. CLAD-LINE F2F (Floor to Floor) Sub-Frame System.Floor to floor spanning support system comprising an extruded vertical sheeting rail (Rail Type 1–2 mm face, Rail Type 2–4 mm face), a Primary Angle Bracket, a BS Link Bracket (allowing for up to 30 degree rotation), Link Bracket Fixing Assemblies, a Fixed Point Clip and a Sliding Point Clip (if required). |
Cavity fire barriers | - |
HorizontalInsert requirements. | - |
VerticalInsert requirements. | - |
Cladding panels | - |
Material | Aluminium folded plank panels. |
Panel joints | Open joints. |
Samples required | None.Panel and finish samples.Samples of fixings.Fabrication samples.Mock-up to validate details. |
Finish | Polyester powder-coated. 60 Microns. A2-s1, d0 classification to EN 13501-1. |
ColourExtensive range of colours. Consult manufacturer and insert requirements. | - |
Thickness | 3 mm. |
Joint widthInsert requirements, 10–20 mm. | - |
Sheeting rails | Continous rails. Individual rails. |
Rail material/ finish | To EN 755, extruded aluminium, 6063/T6 grade alloy. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | 100 |
Recycled content | 65 % |
UNITY A2 FP-T01 VERTICAL JOINT Technical Drawing
UNITY A2 FP-T02 HORIZONTAL JOINT Technical Drawing
UNITY A2 FP-T03 SOFFIT RETURN Technical Drawing
UNITY A2 FP-T04 EXTERNAL CORNER Technical Drawing
UNITY A2 FP-T05 INTERNAL CORNER Technical Drawing
UNITY A2 FP-T06 CILL INTERFACE Technical Drawing
UNITY A2 FP-T07 GLAZING HEAD INTERFACE Technical Drawing
UNITY A2 FP-T08 CAPPING INTERFACE Technical Drawing
UNITY A2 FP-T09 JAMB INTERFACE Technical Drawing
Unity A1 FP (folded plank) Aluminium Rainscreen
Unity A1 X-TRU (Extruded Plank) Aluminium Rainscreen
Unity A1DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding
Unity A1IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding
Unity A1PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding
Unity A1SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding
Unity A1TF (Through Fix) Non-Combustible Aluminium Rainscreen Cladding
Unity A2 X-TRU (Extruded Plank) Aluminium Rainscreen
Unity A2DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding
Unity A2IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding