NBS Source
Unity A1TF (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

Application

Suitable for the replacement of non-compliant ACM, HPL and timber cladding.

Description

A though-fix / face-fixed non-combustible solid rainscreen panel that is cost effective and easy to install.


Features and benefits:

  • Manufactured from non-combustible material that has an A1 classification to EN 13501-1.
  • Developed and manufactured in accordance with CWCT guidelines.
  • Unity rainscreen panels with associated carriers, bracketry and support systems are designed to allow the correct flow of ventilation and drainage run-off in line with current building regulations.
  • Available in anodized or pre-coat finishes in an extensive range of colours.
  • Colour-matched through fixings provide a clean aesthetic finish.
  • Offers protection to a building’s external facade.
  • Can be used to enhance the look and feel of both new build and refurbishment projects.
  • Can be installed horizontally and vertically.
  • Panels available in lengths up to 6000 mm.
  • Design assistance available; consult manufacturer for details.

Part of a range of Unity A1 systems (specified separately) that includes:

  • A floor-to-floor framing system (F2F).
  • A discrete-fix rainscreen system (DF).
  • An interlocking rainscreen system (IL).
  • A secret-fix rainscreen system (SF).
  • An interlocking plank and soffit system (PS).

Installation:

  • The Unity A1 non-combustible rainscreen panel is produced using a solid aluminium substrate that can be fitted as either a cassette or as a flat-faced panel fixed onto an appropriately designed support framework.
  • Rainscreen cladding panel to be fixed to an appropriately designed carrier system.
  • Carrier rail profile to be fixed to a helping hand or primary support bracket through thermal insulation.
  • Helping hand support bracket to be fixed to SFS steel wall and cement board with stainless steel fixings (including thermal isolator).
  • Unity A1 F2F (floor-to-floor framing): Primary support bracket to be fixed back to main structure at every floor level using fixings/anchors which have been designed to withstand the imposed loading.


Consult manufacturer's technical literature for further details.

General information

Finish

Anodized

Pre-coat

Color

Extensive range of colours. Consult manufacturer and insert requirements.

-

Material

Aluminium

Shape

Rectangle

Size

Panels available in lengths up to 6000 mm.

Uniclass 2015

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

Configuration

Horizontal.

Vertical.

Horizontal and vertical.

Horizontal corner section

Required.

Not required.

Panel length

Available up to 6000 mm; insert requirements.

Fire classification (EN 13501-1)

A1.

Finish

Anodized.

Coil-coat.

25 micron minimum, gloss level 25/40%.

Colour

An extensive range of colours available. Consult manufacturer and insert requirements.

-

Thickness

3 mm.

Joint width

Insert requirements, 10–20 mm.

-

Sheeting rails

Continous rails.

Individual rails.

Rail material/ finish

To BS 1474, extruded aluminium, 6063/T6 grade alloy.

Literature

Metalline Unity A1 Brochure - Commercial

Metalline Unity A1 Brochure - Commercial

Metalline Unity A1 Brochure - Offices

Metalline Unity A1 Brochure - Offices

Metalline Unity A1 Brochure - Residential

Metalline Unity A1 Brochure - Residential

Unity A1 TF-01 Technical Drawing

Unity A1 TF-01 Technical Drawing

Unity A1 TF-02 Technical Drawing

Unity A1 TF-02 Technical Drawing

Unity A1 TF-03 Technical Drawing

Unity A1 TF-03 Technical Drawing

Unity A1 TF-04 Technical Drawing

Unity A1 TF-04 Technical Drawing

Unity A1 TF-05 Technical Drawing

Unity A1 TF-05 Technical Drawing

Unity A1 TF-06 Technical Drawing

Unity A1 TF-06 Technical Drawing

Unity A1 TF-07 Technical Drawing

Unity A1 TF-07 Technical Drawing

Unity A1 TF-08 Technical Drawing

Unity A1 TF-08 Technical Drawing

Unity A1 TF-09 Technical Drawing

Unity A1 TF-09 Technical Drawing

Third party certifications

  • A1 classification - BS EN 13501-1

Similar products from Metalline Architectural Fabrications

Unity A1 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A1 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A1DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity A1PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity A1SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A1SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A2 X-TRU (Extruded Plank) Aluminium Rainscreen

Unity A2DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2DF (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2IL (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity A2PS (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity A2SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity A2SF (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding