Verified by manufacturer 18 days ago
Fire stopping between spandrel panel and roof covering
For installing between spandrel panel and roof coverings.
Compressed between the top of the spandrel panel and underside of the roof covering, creating a fire and thermal break.
Features and benefits:
Color | Orange |
Material | Rock fibre mineral wool |
Shape | Manufacturer guidanceU-shape. |
Length | 1200 mm |
Width | 200 mm |
Height | 150 mm |
Uniclass | |
CAWS | F30/18 Cavity closers F30/180 Cavity closers |
Fire performance | To BS EN 13501-1, Euroclass A1. |
Materials | Rock fibre mineral wool. |
ThermalConductivity | 0.037 W/mK. |
Dimensions | 150/200 x 55 x 100/90 x 1200 mm. Manufacturer guidanceSuits single 100 mm spandrel. |
Material | Rock fibre mineral wool |