Verified by manufacturer 8 days ago
40 mm Panel Thickness
FM Approved
Certificate type
BES 6001
Certificate type
ISO 14001 Environmental Management Systems
Certificate type
ISO 9001 Quality Management
Certificate type
BRE Certificate
Certificate type
EPD
Certificate type
Insulated trapezoidal steel wall panel system.
Suitable for horizontal and vertical wall cladding applications.
Trisomet® is an insulated panel manufactured as a single component suitable for horizontal or vertical wall cladding applications. As a one-fix component its consistency enables speed of installation and with a wide spaced trapezoidal steel external skin provides optimum performance for water drainage, strength and walkability. Single, double and multi span configurations are available.
Features and benefits:
Fire performance:
LPS 1181 Grade EXT-B
Trisomet® carries Grade EXT-B and EXT-A approval by the LPCB, Certificate 460a/29. Also fire resistance performance of up to 4 hours integrity and 30 mins insulation dependant on panel thickness. These are attained using standard fixing and sealing methods (external side-lap stitched at maximum 300mm centres).
internal surface of the panel complies with a Class B s2 d0 rating in accordance with EN 13501-1.
Water penetration:
Laboratory testing shows evidence that the Trisomet® system is water-tight up to a pressure of 1200 Pa, which surpasses the relevant standards.
Pa, when tested to BS EN 12865‘Hygrothermal performance of building components and building elements’
Air-tightness:
In accordance with Building Regulations Approved Document L2 (E&W) and Scotland (Technical Handbook Section 6 Energy) tests to EN BS 12114 shows the sealed panel of air leakage as low as 0.43 m³/h/m² at an applied pressure of 50 Pa.
A practical expectation for a finished building, with effective sealing at all junctions, would be 3-5 m³/h/m². However, enhanced detailing practises on large shed buildings can realise air leakage performance figures of less than 3 m³/h/m².
Find out more: https://www.tatasteeleurope.com/construction/products/roof/insulated-panels/trisomet
Color | Other Manufacturer guidanceWide range available. |
Material | Steel Guidance for specification option: Pre-coated steel skins/ PIR core. |
Length | Bespoke |
Width | 1000 mm |
Height | Bespoke |
Warranty description | 25 year |
Uniclass | |
CAWS | H43/10 Metal insulating sandwich panel H43/120 Metal insulating sandwich panel |
Product range |
Cladding panels | |
Panel type | Metal composite panel wall cladding systems. |
Panel fasteners | Carbon steel fasteners.Guidance for specification option: C1, C2 and C3. 304 grade stainless steel fasteners.Guidance for specification option: C1, C2 and C3 - 25-year system guarantee. 316 grade stainless steel fasteners.Guidance for specification option: C4, C5 and CX. Manufacturer guidancePanel fastener materials vary with exposure category. |
Side laps sealing | FASS (Factory applied sidelap sealant).6 x 5 mm high-grade butyl mastic sealant strip (Grade A, minimum 25-year guarantee).Guidance for specification option: Site applied. |
End laps sealing | 6 x 5 mm butyl mastic strip sealant (Grade A, minimum 25-year guarantee).Guidance for specification option: Two lines of 6 x 5 mm butyl mastic strip sealant (Grade A, minimum 25 year guarantee) should be placed between sheets 10 mm from the sheet ends at the top and bottom of the lap. |
Side lap stitching fasteners | Carbon steel fasteners.Guidance for specification option: C1, C2 and C3. 304 grade stainless steel fasteners.Guidance for specification option: C1, C2 and C3 - 25-year system guarantee. 316 grade stainless steel fasteners.Guidance for specification option: C4, C5 and CX. Manufacturer guidanceGenerally at 600mm centres. Panel fastener materials vary with exposure category. |
End lap stitching fasteners | Not required. |
Continuity thermal insulation | PIR closed cell foam.Guidance for specification option: (CFC and HCFC free, zero ODP and GWP <5) to specification used in LPCB approval. |
Samples required | Manufacturer guidanceSamples available for product approval. |
Material | Colorcoat HPS200 Ultra® pre-finished steel. Colorcoat Prisma® pre-finished steel using Galvalloy® metallic coating. |
Grade | S220 Steel. |
Profile | 32 mm high trapezoidal profile with a 333 mm pitch. |
Thickness | 0.5 mm. |
Material | Colorcoat® High Reflect steel. Colorcoat® PE 15 steel. |
Grade | S220 Steel. |
Profile | Lightly planked. |
Thickness | 0.4 mm. |
Length | Manufacturer guidancePanel lengths from 300 mm to 20 m. Maximum manufacturing length 20 m - consider road access and handling restrictions. Insert requirements. |
Cover width | 1000 mm. |
Thickness | 40 mm. |
Panel internal face | Trisomet panels have an internal reaction to fire classification of B-s2, d0. |
Fire resistance | 30 minutes fire insulation. 240 minutes fire insulation. Manufacturer guidanceContact the technical department for specification details. |
Span | As drawing. Guidance for specification option: Insert details. Manufacturer guidanceSpan varies with panel thickness and imposed and wind loads - consult load span tables. |
U-value | 0.46 W/m²K. |
Bearing width | 60 mm. Manufacturer guidance(Minimum). |
Impact sound reduction | 28.5 dB. Guidance for specification option: Further reductions can be achieved, depending on the core thickness, external skin thickness and liner used. Consult technical literature for details. Manufacturer guidanceWeighted SRI Rw (based on 80mm core). |
Weight | 9.23 kg/m². |
Country of product manufacture | United Kingdom |
Material | Steel Guidance for specification option: Pre-coated steel skins/ PIR core. |
Manufacturing plant location | |
Recyclability | All steel elements are recyclable, with ‘end of life’ assumptions for recovered steel and steel recycling being 89% of steel is recycled, 10% of steel reused with 1% loss . We would point out that our panels can be separated using current shredding technology and can be recovered or recycled. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceThe concept of recycled content is a useful metric to stimulate economies of scale around recycling of materials which may otherwise be incinerated or land-filled. But this is not the case for steel. Steel has been recycled for over 150 years and the recycling process and infrastructure is efficient and economical without any added stimulus. Scrap steel is valuable, so wherever it can be recovered it is, and very little steel ever goes to waste.
Provided this is understood we can confirm for the financial year 19/20 Tata Steel Europe produced 10 million tonnes of crude steel, recycling 1.7million tonnes of steel scrap. This equates to a recycled content of 17%. A breakdown of the scrap by source shows that ~9% was internal pre consumer scrap. The remaining ~8% was externally sourced commercial scrap. |
FM Approved
Factory Mutual Approval
BES 6001
BES 6001
ISO 14001 Environmental Management Systems
ISO 14001 / 45001
ISO 9001 Quality Management
ISO 9001
BRE Certificate
Loss Prevention Certification Board - Certificate 460a
EPD
EPD Trisomet 80mm Insulating Roof & Wall Panel
EPD
EPD Trisomet 120mm Insulating Roof & Wall Panel
EPD
EPD Trisomet 100mm Insulating Roof & Wall Panel