QA Certificate
Certificate type
Site assembled horizontal walling system.
Suitable for horizontal design walling applications.
Site assembled walling system with internal and external profiles.
The Trisobuild® systems can be tailored to meet project requirements including fire resistance and acoustic performance.
The Trisobuild® HW System is a horizontally run external wall system which allows the secondary steelwork to remain horizontal with the spacer and bar system spanning vertically between these rails.
The capability of the system has been tested to provide a range of performances. The wall system can achieve up to four hours fire integrity and one hour fire insulation.
Trisobuild® FW (fire wall) range system build-up:
Supporting structures:
When sheeting rails heat up during a fire they cease to function as structural members. Therefore, to prevent the wall from moving downwards under its own self-weight either a support at the head or base of the wall is required.
All Tata Steel firewalls can be designed to be supported from eaves, beams/ stanchions or rafters and posts if situated on a gable end. However, these elements must be protected using conventional fire protection materials to give the same period of fire resistance as the firewall.
Features and benefits:
Applications:
Suitable for horizontal design walling applications.
Uniclass 2015 | |
CAWS | H43/10 Metal insulating sandwich panel H43/120 Metal insulating sandwich panel |
Product Reference | Trisobuild® FW15HFire performance: Integrity: 240 minutes. Insulation: 15 minutes. Trisobuild® FW30HFire performance: Integrity: 240 minutes. Insulation: 30 minutes. Trisobuild® FW60HFire performance: Integrity: 240 minutes. Insulation: 60 minutes. Trisobuild® HW |
Span | As drawingInsert details. |
Height | 120 mmInsulation depth: 140 mm. U-value: 0.35 W/m²K. 140 mmInsulation depth: 140 mm. U-value: 0.30 W/m²K. 160 mmInsulation depth: 160 mm. U-value: 0.26 W/m²K. 180 mmInsulation depth: 180 mm. U-value: 0.23 W/m²K. 200 mmInsulation depth: 200 mm. U-value: 0.21 W/m²K. |
Material/ Finish | - |
External facing | Coloroat HPS200 Ultra® pre-coated steelColoroat Prisma® pre-coated steel |
Internal facing | Coloroat® High Reflect steelPE15 steel |
Colour | Consult technical literature for details and insert requirements. |
Standard product features | Reaction and resistance to fire:
Thermal performance: All quoted system U-values and construction ‘psi’ and f values have been computer modelled in accordance with EN ISO 10211 as stated in the Metal Cladding and Roofing Manufacturers Association (MCRMA) Technical Note 14 by trained and experienced technical engineers. U-Values are based on secondary steelwork support at 1.8 m centres, 1.2 m bracket spacing and insulation with a 0.040 W/mK thermal conductivity. U-values: U-Values are based on an LP1000 liner, secondary steelwork support and brackets at 1.5 m centres, 1.5 m vertical bar spacing and insulation with a 0.040 W/mK thermal conductivity. |
Colorcoat® LG
Colorcoat® pre-finished steel for the building envelope
Confidex Sustain® The world’s first cradle to cradle CarbonNeurtal® building envelope
Photovoltaic installation guidelines for industrial and commercial buildings
Acoustic performance of pre-finished steel cladding systems
Structural performance of built-up roof and wall cladding systems
Ensuring consistent appearance of pre-finished steel wall cladding
Refurbishment solutions for non-domestic solutions
The effect of gauge on pre-finished steel roof and wall cladding performance
Creating an air-tight building envelope