NBS Source
I'm a manufacturer
Compare variants

Trimoterm FTV Steel Insulating Panel - POWER T

Verified by manufacturer 1 month ago

100 mm thick

Trimo UK Ltd Variant:

Steel insulated fireproof panels.

Jump to:
+44 (0)1270 665303 Website

Application

The range of applications for the horizontal joint façade system is extremely wide. They are suitable for business, commercial, leisure, trade and industrial buildings.

Description

The basic horizontal façade system consists of Trimoterm FTV panels of standard modular widths 1000 and 1200 mm.


The horizontal façade system has excellent technical properties, a long life span and allows creative freedom in building envelope design. The system of Trimoterm fireproof panels ensures high fire resistance, excellent thermal and sound insulation. The panels are used primarily as a facade, partition walls, fire walls and ceilings, or even as a back up panels for variety of rainscreen façade systems. CE marked, LPCB, FM certified.


Panels Composition

Trimoterm FTV fireproof panels consist of two shallow profiled, coated sheet faces in thickneses of 0.5 to 0.7 mm. The steel sheet is bonded to the panel core made of non-combustible mineral wool lamellas of class A1 (EN 13501-1). All three layers make a solid panel in a thickness of 50 - 240 mm. Standard width of the panels are 1000 and 1200 mm. Non standard panel width of 600 -1200 mm can be made by a special request. A protective PVC film is applied to the panel surface to protect it during production handling and transport. Panels can be manufactured up to 14 m long.

General information

Finish

Galvanized

Guidance for specification option:

Hot galvanized (net 275 g/m² ) in compliance with EN 10346, and additionally protected by organic coating in accordance with the coil-coating process (DIN EN 10169/1)

Material

Steel

Mineral fibre

Mineral wool

Shape

Rectangle

Square

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Uniclass

Pr_25_71_14_22 Carbon steel insulating sandwich panelsPrimary

CAWS

H43/120 Metal insulating sandwich panel

H43/10 Metal insulating sandwich panel

Specification data - Carbon steel insulating sandwich panels

Panels

Factory-assembled insulating sandwich panels.

Panel construction

-

Panel external face

-

Material

Steel.

Grade

S320GD.

Profile

Micro-lined profile (M).

Micro-lined profile (M3).

S - profile (standard profile).

Smooth profile (G).

V - profile (V).

V - profile (V2).

V - profile (V6)

Guidance for specification option:

1200 mm width.

Thickness

0.5–0.8 mm.

Panel internal face

-

Material

Steel.

Grade

S320GD.

Profile

Micro-lined profile (M2).

S - profile (standard profile).

Smooth profile (G).

V - profile (V).

V - profile (V2).

V - profile (V6)

Guidance for specification option:

1200 mm width.

Thickness

0.4–0.8 mm.

Core insulation

Stone wool, 90 kg/m³.

Panel dimensions

-

Length

-

Manufacturer guidance

14 m (maximum). Insert requirements.

Cover width

1000 mm.

1200 mm.

Thickness

100 mm.

Finish as delivered

-

Outer skin

-

Material

SP.

HDP.

PUR.

PUR-PA.

PVDF.

PVC(P).

Manufacturer guidance

For corrosion protection details consult technical literature.

Colour

-

Manufacturer guidance

Consult manufacturer and insert requirements.

Inner skin

-

Material

SP.

HDP.

PUR.

PUR-PA.

PVDF.

PVC(P).

PVC(F).

PET(F).

Colour

-

Manufacturer guidance

Consult manufacturer and insert requirements.

Integral accessories

-

Manufacturer guidance

Consult manufacturer and insert requirements or omit.

Fire performance

-

Reaction to fire

-

Core

To EN 13501-1, Class A1.

Panel external face

To EN 13501-1, Class A1 and EN 13501-5, BROOF (t1,t2,t3).

Guidance for specification option:

Stand alone panel classification according to EN 13501-1 is A1, once adhesive is applied the overall reaction to fire classification becomes A2.

Panel internal face

To EN 13501-1, Class A1.

Guidance for specification option:

Stand alone panel classification according to EN 13501-1 is A1, once adhesive is applied the overall reaction to fire classification becomes A2.

Fire resistance

Up to EI 90 (horizontal and vertical).

Reaction to fire

Overall system: to EN 13501-1, Class A2.

Thermal transmittance (U-Value)

0.37 W/m²K.

Sound insulation

NPD.

Water permeability

Class A (1200 Pa).

Air permeability

n = 1.5 C= 0.00005.

Burglary resistance (to BS EN 1627)

RC3.

Sustainability data

Country of material origin

Slovenia

Country of product manufacture

Slovenia

Material

Steel

Mineral fibre

Mineral wool

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

60 kg CO₂ eq/m²

Self declared

Recyclability

99%

Guidance for specification option:

Up to 99%.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

40 %

Guidance for specification option:

Up to.

Literature

Packaging transport and storage for Trimo products

Packaging transport and storage for Trimo products

Trimo Product Portfolio Flyer

Trimo Product Portfolio Flyer

Trimoterm Quick Product Finder

Trimoterm Quick Product Finder

Trimoterm Technical Specification

Trimoterm Technical Specification