Verified by manufacturer 1 month ago
100 mm thick
Steel insulated fireproof panels with secreted intermediate fixings.
Invisio is predominantly designed as a vertical or horizontally applied, secret fix, mineral wool façade panel that can be produced in lengths, up to 14 m. The range of use of the FTV INVISIO facades is extremely wide and is suitable for business, commercial and industrial projects.
Invisio is predominantly designed as a vertically applied, secret fix, mineral wool façade panel that can be produced in lengths, up to 14 m. Providing a minimal, clean, homogenous aesthetic, Inviso is extremely fast and economical to install, but the rewards are an appealing flat, architecturally sensitive façade. The intermediate fixing details have a high level of load-bearing capacity and utilises the integral strength of the panel, to the fullest, without compromising the panel flatness.
Trimoterm panels FTV HL (referred as FTV INVISIO) are fixed to the intermediate supports of steel or concrete frames, with steel profiles, by means of a purpose-built spreader bar, the purpose of which, is to spread the loading capacity, to a larger bearing area. The longitudinal edge of the adjacent panel covers the spreader bars and screws of the attached panel in such a manner that they are not visible on the completed façade. CE marked, LPCB, FM certified.
Panels Composition
Trimoterm FTV INVISIO panels are composed of two shallow profiled galvanized and colour-coated steel sheets. The sheet metal is bonded to the panel core, made of non-combustible laminated mineral wool, A1 (EN 13501-1), which ensures excellent thermal and sound insulation of panels as well as the requisite, specified fire resistance. All three layers are bonded to form a composite structure (in a thickness of 50 to 240 mm) that provides load-bearing capability, air/water tightness and various construction applications. A protective foil is glued to the surface of the panels, as protection during handling, transport and mounting. After the installation is completed, the foil is removed. The maximum panel length is 14 m.
Finish | Galvanized Guidance for specification option: Hot galvanized (net 275 g/m² ) in compliance with EN 10346, and additionally protected by organic coating in accordance with the coil-coating process (DIN EN 10169/1) |
Material | Steel Mineral fibre Mineral wool |
Shape | Rectangle Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | H43/120 Metal insulating sandwich panel H43/10 Metal insulating sandwich panel |
Standard | To BS EN 14509. |
Panels | Factory-assembled insulating sandwich panels. |
Panel construction | |
Panel external face | |
Material | Steel. |
Grade | S320GD. |
Profile | Micro-lined profile (M).Micro-lined profile (M3).S - profile (standard profile).Smooth profile (G).V - profile (V).V - profile (V2). |
Thickness | 0.5–0.8 mm. |
Panel internal face | |
Material | Steel. |
Grade | S320GD. |
Profile | Micro-lined profile (M2).S - profile (standard profile).Smooth profile (G).V - profile (V).V - profile (V2). |
Thickness | 0.4–0.8 mm. |
Core insulation | Stone wool, 120 kg/m³. |
Panel dimensions | |
Length | Manufacturer guidance14 m (maximum). Insert requirements. |
Cover width | 1000 mm. |
Thickness | 100 mm. |
Finish as delivered | |
Outer skin | |
Material | SP.HDP.PUR.PUR-PA.PVDF.PVC(P).Manufacturer guidanceFor corrosion protection details consult technical literature. |
Colour | Manufacturer guidanceConsult manufacturer and insert requirements. |
Inner skin | |
Material | SP.HDP.PUR.PUR-PA.PVDF.PVC(P).PVC(F).PET(F). |
Colour | Manufacturer guidanceConsult manufacturer and insert requirements. |
Integral accessories | Manufacturer guidanceConsult manufacturer and insert requirements or omit. |
Fire performance | |
Reaction to fire | |
Core | To EN 13501-1, Class A1. |
Panel external face | To EN 13501-1, Class A1 and EN 13501-5, BROOF (t1,t2,t3).Guidance for specification option: Stand alone panel classification according to EN 13501-1 is A1, once adhesive is applied the overall reaction to fire classification becomes A2. |
Panel internal face | To EN 13501-1, Class A1.Guidance for specification option: Stand alone panel classification according to EN 13501-1 is A1, once adhesive is applied the overall reaction to fire classification becomes A2. |
Fire resistance | Up to EI 120 (horizontal); EI 60 (vertical). |
Reaction to fire | Overall system: to EN 13501-1, Class A2. |
Thermal transmittance (U-Value) | 0.41 W/m²K. |
Sound insulation | 30 (-1;-3) dB. |
Water permeability | Class A (1200 Pa). |
Air permeability | n = 0.8055: C= 0.008996. |
Thermal conductivity (maximum) | 0.043W/mK. |
Resistance | Point load resistance: 1.5 kN / 5 m. |
Burglary resistance (to BS EN 1627) | RC3. |
Country of material origin | Slovenia |
Country of product manufacture | Slovenia |
Material | Steel Mineral fibre Mineral wool |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 60 kg CO₂ eq/m² Self declared |
Recyclability | 99% Guidance for specification option: Up to 99%. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 40 % Guidance for specification option: Up to. |