NBS Source
Thioflex 600

Application

  • Suitable for sealing movement joints in building and civil engineering structures, including superstructures, floors, basements and subways.
  • Recommended for use on high rise buildings and other applications where access for subsequent maintenance may be restricted.

Description

A multi-component, gun and pouring grade, polysulfide sealant for sealing movement joints.


Features and benefits:

  • Forms a tough, elastic, rubber-like seal.
  • Accommodates continuous and pronounced cyclic movement.
  • Designed to adhere to primed concrete, glass, aluminum and stainless steel.
  • Complies with the following standards BS EN 14188-2, TT-S-00227E, DTp Specification for Highway Works Series 1000; ASTM C920-87, LU 1-085.
  • Available in 2.5 L and 5 L packs.

General information

Shape

Formless

Color

Grey

Base: White

Hardener: Black

Material

Polysulfide

WarrantyDescription

A project specific warranty document for an agreed period for products supplied in accordance with a detailed specification document is available on request.

-

Uniclass

Pr_30_31_76_62 Polysulfide construction joint sealantsPrimary

CAWS

E40/530 Sealant

F30/610 Movement joints with sealant

F30/76 Movement joints with sealant

H42/661 Sealant joints

H51/610 Sealant joints

M10/468 Sealant movement joints with metal edgings

Specification data - Polysulfide construction joint sealants Enhanced data

Standard

To BS EN 14188-2, TT-S-00227E, DTp Specification for Highway Works Series 1000, ASTM C920-87, LU 1-085.

Sealant type

Two part polysulfide.

Class

To BS EN 14188-2, Class A, B, C.

Colour

Grey.

Base: White

Hardener: Black

Fire performance

To EN 14187-7, Pass.

Resistance to flame.

Accessories

None.

Primer: Fosroc Primer 7.

Use on concrete, stone, brickwork, timber and unglazed edges of ceramic tiles. Not required on non porous surfaces.

Joint backing: Hydrocell XL.

Bond breaker: Self adhesive bond breaking tape.

Use where there is insufficient joint depth for a cord backing. Not required when using Expandafoam or Hydrocell XL as joint backing.

Joint backing: Expandafoam polyethylene cord backing.

Joint width

Between 5–50 mm.

Specifier to detail.

-

Environmental information

Country of material origin

United Kingdom

Literature

Technical data sheet catalogue

Technical data sheet catalogue

Fosroc Sealants Brochure 2011

Fosroc Sealants Brochure 2011

Concrete Repairs in Accordance with EN1504

Concrete Repairs in Accordance with EN1504

Similar products from Fosroc International Limited

Thioflex 555