NBS Source
I'm a manufacturer
Compare variants

Thermazone® Torch-On Insulation

Verified by manufacturer 9 days ago

Flat board

BMI Group UK Ltd Variant:

Torch-on roof insulation.

Jump to:
0370 560 1000 Website

Application

  • Suitable for use with Icopal Profiles and Total Torch waterproofing systems, and other traditional partial bond torch-on systems.
  • Suitable for use over all types of structural deck and must always be laid over a vapour control layer.
  • Adhesives containing such solvents should not be used in association with this product.

Description

Torch-on polyisocyanurate (PIR) based roof insulation.


Features and benefits:

  • Facing: Faced on the underside with a mineralized glass tissue auto-adhesively bonded to the insulation core during manufacture. The top surface is finished with a bitumen-coated glass tissue finished with a thermofusible polypropylene fleece.
  • Core: Manufactured from a high-performance CFC/HCFC free polyisocyanurate (PIR) based formulation with a typical density of 32 kg/m³. Manufactured without the use of CFCs/ HCFCs and has zero Ozone Depletion Potential (ODP) and a low Global Warming Potential (GWP).
  • Compressive strength: Typically, the compressive strength exceeds 150 kPa at 10% compression and 125 kPa at 5% when tested to BS EN 826:1996.
  • Water vapour resistance: Modified to include board facings, the board achieves a resistance greater than 15 MN·s/g when tested in accordance with ‘BS 4370-2:1993 (Methods of test for rigid cellular materials. Methods 7 to 9)’. Thermazone Torch-on Board must be laid over a vapour control layer.
  • Durability: When correctly applied has an indefinite life. Its durability depends on the supporting structure and the conditions of its use.
  • Resistance to solvents, mould and vermin: The insulation core is resistant to short term contact with petrol and with most dilute acids, alkalis and mineral oils. The insulation core is not resistant to some solvents, e.g. ketonic solvents; such as methylethylketone (MEK).
  • CE marked (EN 13165, 13, 1486).


Thermazone XtraFall Taper System:

  • A Thermazone XtraFall Torch-On System provides the designer and contractor with a precise, technically excellent solution to providing thermal insulation and bespoke drainage on a flat roof.
  • A Thermazone XtraFall Taper System comprises factory laminated boards and factory cut hip and valley pieces which allow for the creation of mitres without on-site cutting thereby reducing installation times, cutting errors and the associated labour and waste costs. Each component is clearly identified by board type and the direction of fall.

General information

Material

Polyisocyanurate (PIR)

Shape

Square

Rectangle

Length

1200 mm

Width

600 mm

1200 mm

Height

25 mm

30 mm

40 mm

50 mm

60 mm

Show more

Uniclass

Pr_25_71_63_66 Polyisocyanurate (PIR) foam boardsPrimary

CAWS

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/115 Single-layer reinforced bitumen membrane warm deck roof covering

J41/120 Built-up reinforced bitumen membrane inverted roof covering

J41/125 Single-layer reinforced bitumen membrane inverted roof covering

J41/410 Expanded polystyrene (EPS) insulation

J41/420 Rigid urethane foam insulation

J42/420 Rigid urethane foam insulation

Specification data - Polyisocyanurate (PIR) foam boards

Standard

To BS EN 13165.

Thermal conductivity (maximum)

0.024 W/mK.

Guidance for specification option:

Insulant thickness > 120 mm.

0.025 W/mK.

Guidance for specification option:

Insulant thickness 80–119 mm.

0.026 W/mK.

Guidance for specification option:

Insulant thickness < 80 mm.

Manufacturer guidance

To BS EN 13165: 2001.

Cross section

Uniform thickness.

Thickness (nominal)

25 mm.
30 mm.
40 mm.
50 mm.
60 mm.
80 mm.
90 mm.
100 mm.
120 mm.
130 mm.
140 mm.
160 mm.

Face size (length x width)

1200 x 600 mm.

Density

32 kg/m³.

Compressive strength at 10% deformation

125 kPa.

Guidance for specification option:

At 10% compression.

150 kPa.

Guidance for specification option:

At 5% compression.

Manufacturer guidance

To BS EN 826: 1996.

Facing

Glass tissue.

Water vapour resistance

To BS 4370-2:1993, 15 MN·s/g.

Similar products from BMI Group UK Ltd

Thermazone Foilboard Insulation

Thermazone Roofboard

Thermazone Roofboard