Flat board
Torch-on roof insulation.
Torch-on polyisocyanurate (PIR) based roof insulation.
Features and benefits:
Thermazone XtraFall Taper System:
Material | Polyisocyanurate (PIR) |
Shape | Square Rectangle |
Length | 1200 mm |
Width | 600 mm 1200 mm |
Height | 25 mm 30 mm 40 mm 50 mm 60 mm |
Uniclass | |
CAWS | J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/115 Single-layer reinforced bitumen membrane warm deck roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/125 Single-layer reinforced bitumen membrane inverted roof covering J41/410 Expanded polystyrene (EPS) insulation J41/420 Rigid urethane foam insulation J42/420 Rigid urethane foam insulation |
Standard | To BS EN 13165. |
Thermal conductivity (maximum) | 0.024 W/mK. Guidance for specification option: Insulant thickness > 120 mm. 0.025 W/mK. Guidance for specification option: Insulant thickness 80–119 mm. 0.026 W/mK. Guidance for specification option: Insulant thickness < 80 mm. Manufacturer guidanceTo BS EN 13165: 2001. |
Cross section | Uniform thickness. |
Thickness (nominal) | 25 mm. 30 mm. 40 mm. 50 mm. 60 mm. 80 mm. 90 mm. 100 mm. 120 mm. 130 mm. 140 mm. 160 mm. |
Face size (length x width) | 1200 x 600 mm. |
Density | 32 kg/m³. |
Compressive strength at 10% deformation | 125 kPa. Guidance for specification option: At 10% compression. 150 kPa. Guidance for specification option: At 5% compression. Manufacturer guidanceTo BS EN 826: 1996. |
Facing | Glass tissue. |
Water vapour resistance | To BS 4370-2:1993, 15 MN·s/g. |