NBS Source
I'm a manufacturer

Technishield 65 non-rebated fire-rated double glazed door 30/30

Verified by manufacturer 5 months ago

Optima Third party certifications:
  • BM Trada

    BM Trada

    Certificate type

Fire-rated glass doorset, non-rebated. 30 minutes integrity and 30 minutes insulation

Jump to:
+44 (0)1494 492725 Website

Application

For use in conjunction with Technishield 65 partition system.

Description

A framed, double-leaf, non-rebated, fire-rated glass doorset on hinges.


Features and benefits:

  • Offering 30 minutes' integrity and insulation.
  • Part M-compliant clear opening included.

General information

Color

White

Silver

Other

Finish

Powder-coated

Material

Glass

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Three year

Guidance for specification option:

See Warranty Policy literature for more information.

Uniclass

Ss_25_30_20_25 Doorset systemsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

Product range

Fire Range
Doorsets

Specification data - Doorset systems

System performance

Fire performance.

Doorset

-

Type

Fire rated glass doorset.

Seals or inserts

-

Door

Manufacturer's standard.

Guidance for specification option:

Dropseal:

Type RO drop seals.

Door seals:

Fire and smoke protection double seal.

Over panels

Not required.

Over panel.

Over panel and side panel.

Guidance for specification option:

Insert requirements.

Side panels

Not required.

Side panel both sides.

Side panel left side.

Side panel right side.

Over panel and side panel.

Guidance for specification option:

Insert requirements.

Hardware

Manufacturer's standard.

Guidance for specification option:

Hinges:

Three face-fitted, weld-on hinges per leaf.

Handles:

Forster stainless steel cranked pull handles.

Lock:

Not applicable.

Euro cylinder:

Not applicable.

Door closer:

TS-93 2-4.

Other.

Guidance for specification option:

Insert requirements; contact manufacturer for information.

Samples required

Not required.

Required.

Finish/ Colour

Powder-coated, RAL.

Guidance for specification option:

Insert requirement; contact manufacturer for more information.

Powder-coated, RAL 9006 Silver.

Guidance for specification option:

50 microns, 30% gloss (nominal).

Powder-coated, RAL 9010 White.

Guidance for specification option:

50 microns, 30% gloss (nominal).

Manifestation

Guidance for specification option:

Insert requirements.

Fire rating

EI30 – 30 minutes' integrity and insulation (30/30).

Size

Guidance for specification option:

  • Door: With over-panel: Available 1850–2350 x 2200–3000 mm (w x h); without over-panel: Available 1850–2350 x 1800–2500 mm (w x h). All dimensions subject to specification and certification.
  • Side panel: Available 300–1100 mm in width.

Configuration

As schedule.

As drawing.

Guidance for specification option:

Insert drawing reference number.

Sustainability data

Country of product manufacture

United Kingdom

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

159 kg CO₂ eq/m²

Self declared

Guidance for specification option:

See Environmental Product Declaration literature for LCA data.

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

BM Trada

BM Trada

009109 (3) - ISO 14001 - Optima Products Limited

BM Trada

BM Trada

000016 (4) - ISO 9001 - Optima Products Limited

Literature

Optima Technishield Product Summary

Optima Technishield Product Summary

000005 (3) - Warranty - Company Policy

000005 (3) - Warranty - Company Policy