Description

System 17 Roof/ Sloped Curtain Walling has been developed for mono or dual pitched roofs with a minimum pitch of 15° from the horizontal, subject to the structural sections being designed to accommodate the applicable loads in accordance with the relevant site conditions and application.

Performance:

– Thermal:

  • All windows/ screens, in conjunction with a suitable glazing specification, have been designed to meet the current requirements of Building Regulations Approved Document L for England and Wales, Technical Handbook 6 for Scotland and Technical Booklet F for Northern Ireland where applicable. Consult with Metal Technology for details.

– Weathertightness:

  • Class III to BS 6375-1: 1989 and BS 5368.

– Dynamic Test: In accordance with the CWCT sequence B test regime using a representative two storey test sample.

  • Static Air Permeability: <1.5 m³/hr at 600 Pa.
  • Static Water Penetration: Zero ml at 600 Pa.
  • Dynamic Water penetration: Zero ml at 600 Pa.
  • Structural performance - 2400 Pa (140 mph).
  • Safety Gust Performance - 3600 Pa (210 mph).

– Deflection:

  • All structural profiles can be designed so that maximum deflection of any member shall not exceed L/200 of its span, with no evidence of any permanent deformation once the load has been removed.

Incorporated components:

A range of specialist roof windows can be incorporated. Consult with Metal Technology for recommendations and details.

Secured by Design:

  • All glazed curtain walling screens, windows, and doors within the ground floor and vulnerable areas shall embrace secure by design.
  • All systems installed must demonstrate that they have been tested in line with PAS24 security standards and certified by a UKAS accredited certification body.

General information

Uniclass 2015

Ss_25_10_20_85 Stick curtain walling systemsPrimary

CAWS

H11/110 Curtain walling

Specification data - Stick curtain walling systems

Product Reference

System 17 Roof/ Sloped Curtain Walling

Internal framing member

-

Material

Extruded aluminium

Finish

Anodized, colour

Insert colour requirements.

Liquid organic coated, colour RAL

Insert colour requirements.

Powder organic coated, colour RAL

Insert colour requirements.

Minimum film thickness

___ micrometres

External cover cap

-

Material

Extruded aluminium

Finish

Anodized, colour

Insert colour requirements.

Liquid organic coated, colour RAL

Insert colour requirements.

Powder organic coated, colour RAL

Insert colour requirements.

Minimum film thickness

___ micrometres

Glazing

Insulating glass units, ___ mm thick

Single glazed panes, 10 mm thick

Glazing system

Dry glazed gasket system

Standard product features

Type:

Stick system, pressure equalized and drained. The system is thermally broken throughout by means of a continuous thermal isolator located between the external pressure plates and internal framing members.

Glazing system:

Dry glazed using proprietary, high performance captive gaskets. All gaskets are bonded and sealed during construction, using waterproof adhesive. All internal gaskets have pre-moulded vulcanized corners.

Roof glazing purlins use a low profiled bevelled pressure plate only. In addition to the proprietary gaskets:

  • A fillet of neutral cure silicone is run along the exposed upper edge of the pressure plates to ensure surface water can flow easily.
  • A butyl tape is deployed across the joint between the double glazed units below the pressure plate and gaskets.

Product Options

Finish/ Colour:

Consult with Metal Technology for availability of colours and to obtain samples.

Minimum film thickness:

Consult with Metal Technology following choice of finish.

Glazing:

Accommodates 10 mm single glazing or 24, 28, or 34 mm insulating glass units.

Panel/ Facing types:

A variety of panel thicknesses can be accommodated within the system. Consult with Metal Technology for recommendations and details.

Similar products from Metal Technology Ltd

System 17 High Rise SP Curtain Walling