Verified by manufacturer 2 days ago
Polymer modified bitumen membrane roofing system.
Reinforced bituminous membrane roof waterproofing.
A polymer-modified bitumen, torch-applied roof membrane system.
STRATAPRO M is a multi-layer composite bitumen waterproofing membranes. The underside of the membranes are made of SBS modified bitumen, while the upper layer is made of APP modified bitumen. The SBS on the lower face offers high level of flexibility, and boast elongation of up to 2000%, it will remain flexible in temperatures as low as –25°C, and has a high resistance to thermo-oxidative ageing. The upper layer consists of an elastoplastomeric mix of distilled bitumen, atactic and isotactic polypropylene and UV resistant polyolefin elastomers, supplemented with thermal shock stabilisers.
The membrane has a composite prefabricated three-layer reinforcement system. A fibreglass mat is compressed between two layers of nonwoven polyester fabric, this reinforcement limits the movements of the membrane both at high and low temperatures providing stability to the membranes.
Suitable for both torched application and mechanical fixing, the fibers within the membrane are impregnated and coated with an elastomeric mix using an exclusive procedure which guarantees absolute waterproofing, high resistance to tearing and impact, and excellent elasticity even at low temperatures.
Features and benefits:
System Includes:
Color | Grey |
Finish | Mineral |
Material | Bitumen |
Shape | Rectangle |
Length | 8000 mm |
Width | 1000 mm |
Height | 4 mm Guidance for specification option: Thickness |
Uniclass | |
CAWS | J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/10 Reinforced bitumen membrane warm deck roof covering |
Preparation | |
Horizontal work | Strataprime.Guidance for specification option: ICB STRATAPRIME is a black priming solution designed to deeply penetrate and seal porous surfaces to provide a base for bituminous waterproofing and flashing systems. It contains a wetting agent to enable it to be applied to ‘damp’ as well as dry surfaces. |
Skirtings and vertical work | Strataprime.Guidance for specification option: ICB STRATAPRIME is a black priming solution designed to deeply penetrate and seal porous surfaces to provide a base for bituminous waterproofing and flashing systems. It contains a wetting agent to enable it to be applied to ‘damp’ as well as dry surfaces. |
Insulation | |
Type | Evatherm T Insulation, 1200 x 600 mm.Guidance for specification option: Evatherm T is a closed cell, CFC and HCFC-free (zero ozone depletion), rigid polyisocyanurate foam core faced board, with a Bituminous coated glass fleece on both sides. It has an exceptionally low thermal conductivity of 0.024 W/mK. Thickness: 30, 40, 50, 60, 70, 80, 90, 100, 120, 130, 140, 150 mm. Consult literature and insert requirements. |
Fixing | Instastik.Guidance for specification option: INSTA-STIK Roofing Adhesive is a specially formulated polyurethane foam adhesive for the purpose of adhering rigid insulation boards to flat roofs. |
Waterproof covering | |
First layer | |
Type | Stratabase SBS.Guidance for specification option: STRATABASE-SBS and STRATACAP-SBS consist of a special compound based on distilled bitumen modified with selected elastomers and reinforced with a non-woven spunbond polyester reinforcement, which offers good characteristics of mechanical resistance, ultimate elongation and dimensional stability. The SBS modified waterproofing compound assures good flexibility at low temperatures and excellent properties of elongation and resistance to roof movements. Manufacturer guidanceRoll size: 1 x 8 m. |
Attachment | Torch-applied. |
Top layer | |
Type | Stratapro M.Manufacturer guidanceRoll size: 1 x 8 m. Thickness: 4 mm. |
Attachment | Torch-applied. |
Detail work | |
Welted drips | Contractor to form suitably sized welted drip on site. |
System accessories | Ryno GRP Pultruded glass fibre reinforced polyester roof edge trim.Guidance for specification option: Installation: RynoTrim is fixed over the first layer of a built-up roofing system. The trim should be fixed at maximum 300 mm centres, using suitable fixings. Welted Drip.Guidance for specification option: Contractor to form suitably sized welted drip on site. Lead Flashing.Guidance for specification option: Created on site using suitable code lead and following the relevant codes of practice. FPA Profile.Guidance for specification option: Mechanically fixed to the wall 150 mm min. above finished roof level. Fixed at 200 mm centres using ICB approved fixings. Roof Vent.Guidance for specification option: Manufacturer: RYNO – Product of ICB (Waterproofing) Ltd. - Product reference: Ryno Breather Vent Diameter: 75 mm. Ryno Flat Flange Outlets Diameter: 50–150 mmGuidance for specification option: Manufacturer: RYNO – Product of ICB (Waterproofing) Ltd. - Product reference: Ryno Flat Flange Outlets Diameter: 50mm-150mm Ryno Horizontal Outlets Diameter: 65 / 100 mm.WalkwayGuidance for specification option: Product reference: Stratawalk Colour: Red. |
Vapour check | Stratacon Guidance for specification option: STRATACON is a torch on membrane consisting of a compound based on elastoplastomeric modified bitumen reinforced with a strengthened glass fibre mat. Manufacturer guidanceRoll size: 1 x 1.5 m. Thickness: 2 mm. |
Material | Bitumen |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0.06 kg CO₂ eq/unit Self declared |