NBS Source
I'm a manufacturer
Compare variants

Stopsol

Verified by manufacturer 17 days ago

Stopsol position 1/ 16 mm air/ iplus AS position 3

AGC Glass UK Ltd Variant:

Pyrolytic-coated glass with a reflective appearance for enhanced solar control.

Jump to:
Website

Application

  • Suitable for exterior applications such as facades and windows in office and residential buildings especially in densely built-up urban areas.
  • Appliances (oven doors) and interior applications (partitions).
  • Monolithic glass and in insulating and laminated glazing.
  • Can be heat-treated, bent, enamelled, silkscreen printed and does not require edge deletion.

Description

Pyrolytic-coated glass with a reflective appearance for enhanced solar control.


Features and benefits:

  • Extremely stable, consistent performance.
  • Highly-reflective surface provides privacy when viewed from the outside.
  • Range of colours, in two types of coatings (Classic and Supersilver).
  • Flexibility - can be used for multiple applications.
  • Multiple combinations of solar control and light transmission levels allow for freedom of design.
  • Easy to process and can be stored for many years.

General information

Color

Material

Glass

Warranty description

Ten year

Uniclass

Pr_25_71_33_02 Annealed glass sheetsPrimary
Pr_25_71_33_88 Thermally toughened glass sheets

CAWS

L40/210 Putty-fronted single glazing

L40/230 Bead-fixed single glazing – non-setting compound

L40/250 Bead-fixed single glazing – tape and sealant

L40/260 Bead-fixed single glazing – extruded gasket

L40/310 Bead-fixed single glazing – tape, sealant and trim

L40/330 Bead-fixed single glazing – capping

L40/370 Bead-fixed insulating glass units – insert gasket sections

L40/371 Bead-fixed insulating glass units – cellular adhesive/ mastic tape

L40/372 Bead-fixed insulating glass units – loadbearing tapes/ synthetic rubber and sealant capping

L40/350 Bead-fixed single glazing – curing compound and trim

L40/380 Bead-fixed insulating glass units – solid bedding, outside bead

L40/381 Bead-fixed insulating glass units – solid bedding, inside bead

L40/410 Single glazing into grooves – extruded rubber/ PVC sections

L40/430 Single glazing into grooves – non-setting compound

L40/450 Single glazing into grooves – sealant capping

L40/490 Single-sided gasket glazing

H10/115 Patent glazing

H13/115 Structural glass assembly

L40/530 Internal tape glazing

H10/10 Patent glazing

L10/10 Wood windows

L10/15 Wood windows

L10/25 Aluminium windows

L40/50 Bead-fixed single glazing

L40/40 Putty-fronted single glazing

L40/55 Bead-fixed insulating glass units – drained and ventilated bead

L40/57 Bead-fixed insulating glass units – solid bedding, outside bead

L40/58 Bead-fixed insulating glass units – solid bedding, inside bead

H11/110 Curtain walling

L10/330 Aluminium windows

L10/350 PVC-U windows

L10/210 Wood windows

L10/310 Steel windows

L10/390 Proprietary windows

L10/400 Composite windows

L10/580 Secondary glazing system

L40/470 Zipper gasket glazing

L10/20 Steel windows

L10/30 PVC-U windows

L10/33 Proprietary windows

L10/31 PVC-U windows

L40/90 Internal tape glazing

Specification data - Annealed glass sheets

General requirements

Glass generally.

Composition

Manufacturer's standard.

Thickness

Manufacturer's standard.

Guidance for specification option:

Overall thickness will vary based on which glazing combination is specified; consult manufacturer's literature for details.


All individual panes are 6 mm thick (Stopsol; Planibel G; iplus Solid; iplus AS).

Body colour

Classic Clear.

Classic Grey.

Classic Green.

Classic Bronze.

Supersilver Clear.

Supersilver Grey.

Supersilver Green.

Classic Dark Blue.

Supersilver Dark Blue

Supersilver Blue Green.

Manufacturer guidance

External appearance will vary based on which glazing combination is specified; consult manufacturer's literature for details.

Coating

-

Type

Reflective.

Design

Solid.

Guidance for specification option:

Standard.

Screen print.

Guidance for specification option:

Insert requirements.

Performance requirements

-

Fire performance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Light

Manufacturer's standard, to EN 410:2011.

Guidance for specification option:

Transmission and reflectance will vary based on which glazing combination is specified; consult manufacturer's literature for details.

External and internal reflectance values available.

Solar control

Manufacturer's standard, to EN 410:2011.

Guidance for specification option:

Will vary based on which glazing combination is specified; consult manufacturer's literature for details.

Total shading coefficient

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Sound attenuation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Impact resistance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Thermal transmittance (U-Value)

To EN 673, 1.4 W/m²K.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Material

Glass

Literature

Solar Control Glass by AGC

Solar Control Glass by AGC

Solar Control Glass and Low Emissivity Glass for Thermal Insulation by AGC

Solar Control Glass and Low Emissivity Glass for Thermal Insulation by AGC