NBS Source
I'm a manufacturer

Smoke Curtain SmokeStop DH60 - Vertical Active Smoke Curtain - Vertical Smoke Curtain

Verified by manufacturer 3 months ago

Coopers Fire Ltd Third party certifications:
  • Warringtonfire

    Warringtonfire

    Certificate type

Active smoke barrier that deploys vertically to protect escalators and atria from smoke in standard commercial buildings.

Jump to:
BOS
+44 (0)23 9245 4405 Website

Application

Suitable for use in atria, lobbies and receptions, compartmentation, stairs and escalators, lifts and lift lobbies.

Description

Is an active smoke barrier that deploys vertically to protect escalators and atria from smoke in standard commercial buildings. It suits all types of ceiling configurations to integrate with both solid and suspended ceilings. It remains hidden within a ceiling until deployed. It is supplied with the Coopers Total Gravity Fail Safe (TGFS) system, high temperature motors, side channels, variable speed, warning systems and controlled descent. Barrier assemblies shall be tested for fire resistance to BS EN 1363-1, tested for permeability BS EN 1634-3 as required by BS EN 12101-1:2005+A1:2006, and be classified to BS EN 13501-4.


Active smoke barrier assemblies shall comprise of a fire resistant fabric which is wound onto a steel roller, with 1:600 deflection performance to BS 6323-5, which is powered by an internal 24 V d.c. electric motor. They are enclosed within a 1.2 mm-thick galvanized carbon steel box. A bottom bar to suit the deflection performance requirements of the project and the desired ceiling configuration is fitted to the bottom edge of the fabric curtain.


Motors shall meet all applicable safety standards. Motors shall contain the necessary drive mechanisms, a mechanical epicyclic gearbox retarder, automatic overload protection and both automatic and manual distance travel positioning, linked to an internal 24 V d.c. electromagnetic brake with regenerative braking system. When motors are retracted, their internal drive motor shall be isolated from all power and the barrier shall be held in position by an internal electromagnetic brake. This ensures the barriers do not drift upward or downward.


The barrier assemblies shall operate with fail-safe by gravity, using patented Total Gravity Fail Safe (TGFS), in accordance with BS EN 12101-1:2005+A1:2006, and be able to move to their fire operational position even in the event of open or closed circuit wiring, or total system corruption, with controlled braking system and drive mechanisms. All working parts shall be totally enclosed and protected within the steel roller and shall be tested as part of the complete assembly for fire resistance.


The barrier assemblies must show the tested ability to use a range of heavy bottom bar weights in order to meet the critical anti-deflection performance requirements, as required in design guides BS 7346-4, BR 368. The bottom edge of the smoke barrier shall incorporate a heavy bottom bar with a minimum standard weight of 3 kg/m with the facility to increase this weight to 10 kg/m to ensure positive operation when subjected to pressure.


Operation:

The barrier assemblies type ASB1 and ASB3 for "Life Safety" shall move to their fire operational position in a controlled manner when all consumable primary and auxiliary power sources are removed, in the event of wiring, open or short circuit, or system corruption, or any combination thereof.


The barrier assemblies shall fail-safe by gravity, using patented true TOTAL (TGFS), and 'drive up' with mains power available. In the event of mains power failure, they shall remain retracted using their own dedicated battery back-up power supply for a pre-determined period (normally 30 minutes). If signalled to descend during this period, they shall fail-safe by gravity in a controlled manner to their fire operational position. This safety feature is essential to avoid dangerous guillotine/ free-fall deployment.


The barrier assemblies must commence movement upon initiation or any initiation, power or system failure and move to the fire operational position, in all operating modes, at site specific adjustable and synchronised velocities within the range of 0.06 m/s to 0.30 m/s using the unique VarioSpeed™ function. Barrier assemblies which are located in critical areas of the project, e.g. escape routes to have synchronised velocities within the range of 0.06 m/s to 0.15 m/s using the VarioSpeed™ function.


Operating speeds shall be site adjustable without altering bottom bar mass. Speeds may be dictated by those authorities having jurisdiction for 'safety in use' according to the location, nature or function of each unit.


The barrier assemblies shall have the facility to deploy to a partial drop position prior to moving to their fire operational position under both mains and emergency power. Barrier assemblies in their retracted or 'stalled' position shall have all power removed from the motor(s) to prolong motor life. Barrier assemblies that require multiple overlapping barriers shall have a continuous bottom bar system conjoining the run with mutual operation, i.e. one down - all down (handshaking).


The barrier assemblies shall have a 'soft ascent facility' to ensure no damage to the surrounding ceiling interface when retracting. The barrier assemblies shall have a built-in protection in the event that they are prevented from ascending to their retracted position, or descending to their fire operational position. This ensures they are always in their required position and avoids damage to the barrier assemblies' mechanism and surrounding ceiling finishes. In sensitive ceiling aesthetic areas, a unique patented SLAT® ceiling interface can be provided. Any combination of the alarm/ control system provided by the electrical subcontractor, and/ or the specified fail-safe functions shall activate the system.


The barrier assemblies must prove the ability to operate within edge gaps between 20, 40 and 60 mm, height dependent, in all other situations unless the fabric edge interfaces with a retention system, i.e. side guides to resist pressure (as standard 25 Pa). If side guides are provided they shall have formed part of the complete system test in accordance with BS EN 12101-1:2005+A1:2006.


Period of fire resistance:

60 minutes integrity.


Complete barrier assemblies are CE marked in accordance with the EU Construction Products Directive (89/106/EEC).

General information

Color

Other

Finish

Galvanized

Material

Fabric

Guidance for specification option:

  • Flexible metallic fabric.
  • The fabric material shall be tested as part of the complete assembly complete with overlapping barrier panels in the orientation and standard use of the application and installed in accordance with the fire resistance test in BS EN 1363-1, as required by BS EN 12101-1:2005+A1:2006.
  • The fabric material (part of the original test specimen) shall be tested for permeability to BS EN 1634-3 with a rate < 25 m³/h/m² at ambient temperature at 25 Pa.
  • The fabric material shall be tested independently to reaction to fire tests in accordance with BS EN ISO 1716 and BS EN 13823 to achieve an A2-s1, d0 classification in accordance with BS EN 13501-1+A1 in accordance with A11 of Approved Document B (Volumes 1 and 2) 2006 Edition 'Fire Safety' to England and Wales Building Regulations 2000.
  • The fabric material shall be tested independently for fire propagation to BS 476-6+A1, and for surface spread of flame to BS 476-7 to achieve National Class 0 in accordance with A13(b) of Approved Document B (Volumes 1 & 2) 2006 Edition 'Fire Safety' to England and Wales Building Regulations 2000.
  • Fabric type is EFP™ 2/A2 a glass fibre fabric coated with a micronized aluminium filled fire retardant polyurethane 455 g/m² -5% +10%.


Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

One year

Guidance for specification option:

From date of commissioning.

Uniclass

Pr_25_80_79_94 Vertical active fire curtain barriersPrimary

CAWS

L20/610 Roller shutters/ curtains

Specification data - Vertical active fire curtain barriers

Standards

BS EN 12101-1+A1, BS EN 1363-1, BS EN 1634-3, BS EN 13501-4, BS EN ISO 1716, BS EN 13823, BS EN 13501-1, BS 476-6, BS 476-7.

Barrier assemblies

To BS EN 12101.

Test standards

To BS EN 12101.

Third-party certification

Certifi - Warrington Fire.

Size

Bespoke.

Guidance for specification option:

Consult manufacturer and insert requirements.

Performance

-

Pressure and impact

SD.

Durability class

C1.

Smoke containment

To BS EN 12101.

Fire resistance

60 minutes.

Reaction to fire

To BS EN 13501-4.

Barrier units

Single.

Multiple.

Deployment

Full.

Split drop delay.

Accessories

None.

Beam protection and obstruction warning.

Emergency retract.

Split drop delay.

Visual alert system.

Voice warning.

Opening size

Guidance for specification option:

Insert requirement, approved for spans unlimited in width, heights up to 10.5 m, minimum panel overlap 400 mm.

Classification

DH60, A2-s1, d0, Class 0.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

Coopers Fire offer a take back service where product is broken down into component parts.
Metal = recycled
Fabric = recycled
WEEE = disposed through correct channels

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit

Revit 2017

1

IFC
-

1

Third party certifications

Warringtonfire

Warringtonfire

SMOKESTOP SMOKE CURTAIN

Literature

SmokeStop™ Smoke Curtain Barrier

SmokeStop™ Smoke Curtain Barrier

Case studies

GREAT MOSQUE OF MECCA TUNNELS, MECCA, SAUDI ARABIA

GREAT MOSQUE OF MECCA TUNNELS, MECCA, SAUDI ARABIA