Smoke Curtain - SmokeStop D600A - Vertical Active Smoke Curtain - Vertical Smoke Curtain

Verified by manufacturer 3 months ago

Coopers Fire Ltd Third party certifications:
  • Warringtonfire

    Warringtonfire

    Certificate type

Smoke curtain available in a number of standard sizes.

Jump to:
BOS
+44 (0)23 9245 4405 Website

Application

Suitable to be used to form a virtually continuous barrier against smoke.

Description

An electrically operated active smoke curtain barrier assembly used to form a virtually continuous barrier against smoke. Barrier assemblies comprise a metallic fabric wound on to a steel roller, powered by an internal 24 V d.c. electric motor, enclosed within a 1.2 mm (0.047 in) thick stainless steel box. A bottom bar is fitted to the bottom edge of the curtain providing tension to the curtain with sufficient weight for the curtain to ‘fail-safe by gravity’.


The 24 V motor contains an electromagnetic brake to arrest motion of the curtain when in the open position. Barrier assemblies have been tested to the requirements of BS EN 12101:2006, Annex B for ‘Reliability and response times’ (1000 cycles on primary power and an additional 50 cycles using back-up power; closing speed of 0.15 m/s). Barrier assemblies have been tested to the requirements of BS EN 12101:2006, Annex C for ‘Permeability of materials to smoke’ (0.3 m3/h/m2. Barrier assemblies have been tested to the requirements of BS EN 12101-1:2006, Annex D for ‘Temperature/ Time Resistance Tests’ (120 minutes integrity).


Period of Fire Resistance:

120 minutes (2 hours) integrity.


Certification:

Complete barrier assemblies are certified by an independent accredited certification body operating to ISO/IEC 17065:2012. Complete barrier assemblies are certified with an independent accredited certification body operating an accredited United Kingdom Accreditation Service (UKAS) scheme for installation, commissioning and servicing.


Operation:

Barrier assemblies commence movement upon initiation of BMS alarm or power or system failure, and fully deploy to the fire operational position within the range of velocities of 0.06 m/s to 0.15 m/s using the unique VarioSpeed™ function. Operating speeds are site adjustable without altering the bottom bar mass. Speeds may be dictated by those authorities having jurisdiction for ‘safety in use’ according to the location, nature or function of each unit.


In the event of a mains supply power failure, the curtain is retained in the open position for a pre-determined period (nominally 30 minutes), using battery back-up power. During this period, the SmokeStop® D600A active smoke curtain barrier assembly will deploy on receipt of a signal. At the end of the period, the Barrier assembly will deploy.


Product certification, performance and/ or testing:

  • Complete barrier assemblies are certified by an independent accredited certification body operating to ISO/ IEC 17065:2012.
  • Complete barrier assemblies are certified with an independent accredited certification body operating an accredited United Kingdom Accreditation Service (UKAS) scheme for installation, commissioning and servicing.
  • Complete barrier assemblies have been tested for fire resistance to BS EN 1634-1. The Barrier assembly achieved 120 minutes Integrity.
  • Complete barrier assemblies have passed tests to BS EN 12101:2006, Annex B for ‘Reliability and response times’.
  • Complete barrier assemblies have passed tests to BS EN 12101:2006, Annex C for ‘Permeability of materials to smoke’.
  • Motor(s) used within barrier assemblies have passed elevated temperature operational tests to BS 8524-1:2013, Annex G.


Approving standards:

The following standards apply to this product:

  • BS EN 12101-1:2006, Smoke and heat control systems: Part 1 – Specifications for smoke barriers.
  • BS 476 Pt 6; Fire propagation.
  • BS 476 Pt 6; Fire propagation.
  • BS EN ISO 1716:2010; Determination of the heat of combustion for building products.
  • BS EN 13823:2010; Reaction to fire test for building products.
  • BS EN 13823:2010; Reaction to fire test for building products.
  • BS 6853:1999: Annex B.2; Determination of weighted summation of toxic fume.
  • BS EN 14184-1:2011; Determination of formaldehyde – Part 1: Free and hydrolysed formaldehyde.
  • BS 8524-1:2013, Annex G, “Test method for reliability of motor operation at elevated temperatures”.
  • BS EN ISO 9001:2015, Quality management system.
  • BS EN ISO 14001:2015, Environmental management system.

General information

Finish

Galvanized

Powder-coated

Material

Fabric

Guidance for specification option:

Flexible metallic fabric.

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

One year

Guidance for specification option:

From date of commissioning.

Uniclass

Pr_25_80_79_94 Vertical active fire curtain barriersPrimary

CAWS

L20/610 Roller shutters/ curtains

Specification data - Vertical active fire curtain barriers

Standards

BS EN 12101-1+A1, BS EN 1363-1, BS EN 1634-3, BS EN 13501-4, BS EN ISO 1716, BS EN 13823, BS EN 13501-1, BS 476-6, BS 476-7.

Barrier assemblies

To BS EN 12101.

Test standards

To BS EN 12101.

Third-party certification

CE Marked, Warrington fire, Certifi.

Size

Bespoke.

Guidance for specification option:

Consult manufacturer and insert requirements.

Performance

-

Pressure and impact

SD.

Durability class

C1.

Smoke containment

To BS EN 12101.

Fire resistance

To BS EN 13501-4, 120 minutes (2 hours) integrity.

Reaction to fire

To BS EN 13501-4.

Barrier units

Single.

Multiple.

Deployment

Full.

Partial.

Split drop delay.

Side channels

End fixed.

Recessed fixed.

Guidance for specification option:

Recommended 5 mm gap between side guide and building material.

Concealment

Flush fit.

Suspended ceiling with recessed shadow gap.

Suspended ceiling with patented SLAT™.

Guidance for specification option:

Self levelling access trim.

Fixing

Face fixed.

I beam.

Soffit fixed.

Unistrut and drop rods.

Arrangement

Upside down.

Vertical.

Opening sizes

Guidance for specification option:

Insert requirement.

Frame colour/ finish

Galvanized.

Powder coated.

Guidance for specification option:

Insert colour requirement.

Classification

D120, D600A, A2-s1, d0, Class '0'.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

Coopers Fire offer a take back service where product is broken down into component parts.
Metal = recycled
Fabric = recycled
WEEE = disposed through correct channels

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

8

Revit

Revit 2017

8

Third party certifications

Warringtonfire

Warringtonfire

SMOKESTOP SMOKE CURTAIN

Literature

SmokeStop™ Smoke Curtain Barrier

SmokeStop™ Smoke Curtain Barrier

Case studies

Adidas Superstore, Paris - Smoke Curtain Barrier

Adidas Superstore, Paris - Smoke Curtain Barrier

Battersea Power Station, London

Battersea Power Station, London

GREAT MOSQUE OF MECCA TUNNELS, MECCA, SAUDI ARABIA

GREAT MOSQUE OF MECCA TUNNELS, MECCA, SAUDI ARABIA