Verified by manufacturer 16 days ago
System 1
Slipfast® is a fast track, mechanically fixed clay brick slip system, designed to be compatible with modern methods of construction.
The system build-up is suitable for timber or metal framed structures for both onsite and offsite applications. The system is also suitable for coastal environments without modification. Sub-frame options include:
SLIPFAST® is a clay brick cladding system that offers the timeless appearance of fired clay brick, while its innovative design means it is rapid to install, and durable enough to stand the test of time. It has been designed to provide a flexible approach to system build-up on timber or metal framed structures. The system is KIWA BDA Certified and CWCT tested.
Features and benefits:
System 1 - Timber battens or 35 mm galvanized steel top-hat profiles:
System 2 - Allface aluminium support frame:
Color | Black Red Blue Brown White |
Material | Clay Clay brick slips. Stainless steel Core mechanical components. Steel Galvanized steel top-hat profiles. Aluminium Allface aluminium support frame. |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H92/120 Rainscreen cladding H51/110 Cladding H51/110 Cladding |
System performance | Fire performance: Reaction to fire to EN 13501-1, Class A2. |
Thermal insulationAs per Benx project specification. | - |
Breather membrane | - |
Material | Self-Adhesive EPDM membranes to all openings. |
Secondary support structure | Pre-coated panels with fixed stainless steel rails and clips. |
Cladding panels | - |
Material | Pre-formed fired clay brick slips. |
Panel joints | Pointing mortar. |
Colour | Anthracite Black. Apedale Smooth. Avon Red Sanded. Belton Buff Dark. Chester Blend. |
ConfigurationSystem configuration. | Timber battens. Galvanized steel top-hat profiles. |
Edges | Square. Do not require interlocking. |
Fixings | Stainless steel. |
Panel sizeAvailable in various sizes and align to brick courses. Insert requirements. | - |
Reaction to fire (to BS EN 13501-1) | A2. |
Water penetrationStatic pressure and dynamic aero engine. | 600 Pa. CWCT. |
Wind resistance | Serviceability, 2400 Pa; safety, 3600 Pa. CWCT. |
Impact resistance | Retention of performance, Category B (Class 4) resistant to ≥ 500 J equivalent impact; safety to persons, Category B (low risk). CWCT. |
Wind loadDynamic wind uplift. | 3600 Pa/ 2.4 kN/m². CWCT/ KIWA (Lucideon tested). |
Air leakageAir leakage - infiltration. | 600 Pa/ 100 Pa. CWCT. |