CW-FB Fireboard is specially engineered to facilitate advanced performance of CW-FS Firestop at the slab edge for the required fire resistance period.

Jump to:
BOS
+44 (0)1656 730833 Website

Application

Siderise CW-FB curtain wall fireboard forms part of a perimeter barrier firestop and spandrel zone protection system for use with non-fire rated aluminium curtain wall facades. 


The fire resistance performance of CW-FS Firestop, functioning as a perimeter barrier, in combination with CW-FB Fireboard, has been tested in conjunction with commercially available ‘Type A’ non-fire rated curtain wall constructions. This configuration allows in-test deflection of both the façade and the floor slab, incurred as a result of being subjected to over 1000°C during the test, to be considered - giving a more accurate indication of in-application performance.


EN 1364-4 testing is the primary route for compliance for testing firestops in horizontal orientation in combination with curtain wall facades. When testing to EN 1364-4 in combination with 'Type A' non-fire rated curtain walls it is necessary to protect the spandrel zone with Siderise CW-FB. ‘Type A’ is the most common type of curtain wall in the UK. Please see our public website for EN 1364-4 tested arrangements and standard details. The CW-FB does not have a product specific fire resistance performance however it facilitates the fire resistance performance of the CW-FS Firestop in the EN 1364-4 test arrangement.


There are specific configurations of the test that can be chosen depending on the primary element to be assessed. To understand these further, please refer to BS EN 1364-4:2014. In a very simplified explanation, Configuration 2 is used to assess performance of the façade, and incorporates flaming on the inside and outside of the façade with specific furnace pressures and temperatures; this configuration would be used by system manufacturers for specific data on the façade. Configuration 5 is used to assess the linear joint seal/firestop in application and focusses on the ability of containing the fire inside the compartment, utilising higher temperatures and pressures. All Siderise EN 1364-4 testing is carried out in accordance with configuration 5. 


Whilst existing test data is unlikely to replicate specific project details, Siderise have tested to EN 1364-4 with a number of different curtain wall systems with CW-FB in both single and double-layer arrangements.  


In combination, CW-FS and CW-FB can be used in curtain wall façade assemblies requiring enhanced fire resistance performance. 


The product combination provides the following advantages in the test arrangement: 

  • Protection of mullions and transoms 
  • Enhances the performance of the covered area of curtain wall to enable the CW-FS Firestop to perform for the required period of fire resistance 
  • CW-FB is used as part of the tested arrangements to EN 1364-4 to allow the CW-FS Firestop to be certified for both 120 and 180 minutes integrity and insulation 
  • Market-leading performance 

Description

Siderise CW-FB curtain wall fireboard is a high-density stone wool board specifically engineered to provide a simple and easy to install method of facilitating the fire resistance performance of the CW-FS Firestop in conjunction with non-fire rated curtain wall facades.


Based on the experience gained through being the premier supplier to the UK and UAE curtain walling markets, the products represent an unrivalled combination of fully qualified performance, and practical installation and service benefits.


The standard sheet size is 2000mm x 1180mm. It may be provided in pre-cut sizes when the dimensions of the spandrel area are known.


Features and benefits:

  • Maximises curtain wall performance: CW-FB Fireboard helps prolong the performance of the curtain wall spandrel assembly preventing the compartmentation line at the perimeter joint from being breached, whilst reducing the likelihood of fire from breaking out through the spandrel panel itself. 
  • Outstanding fire performance: CW-FB Fireboard has been tested multiple times as part of the CW Perimeter Barrier System to EN 1364-4, ASTM E2307, and ASTM E2874 in combination with commercially procurable non-fire rated curtain wall constructions – enabling CW-FS Firestop in the void between the floor assembly and façade to achieve third-party certified fire resistance performances up to 180mins. 
  • Multiple arrangements: CW-FB Fireboard has been utilised in both single and double-layer arrangements to facilitate the testing of CW-FS Firestop.

General information

Color

Silver

Finish

Foil

Guidance for specification option:

Foil facing top and bottom.

Material

Mineral wool

Shape

Square

Length

2000 mm

Width

1180 mm

Guidance for specification option:

United Kingdom

1200 mm

Guidance for specification option:

Middle East

Height

25 mm

Material

Mineral wool

Uniclass

Pr_25_80_81_51 Mineral wool fire-stoppingPrimary

CAWS

H11/780 Thermal insulation

P12/360 Mineral wool rigid batts

P12/40 Mineral wool rigid batts

Product range

Curtain Walling

Specification data - Mineral wool fire-stopping

Material

-

Standard

To BS EN 1364.

Third-party certification

Certifire and Intertek certified.

Type

Fixed.

Density

160 kg/m³ (nominal).

Facing

Aluminium foil.

Fire performance

Siderise CW-FB curtain wall fireboard is tested to EN 1364-4: 2014 and certified up to 180 minutes (integrity and insulation) when used in conjunction with CW-FS180 Perimeter Barrier, and 120 minutes (integrity and insulation) when used in conjunction with CW-FS120 Perimeter Barrier.

Length

1200 mm.

ThermalConductivity

0.042 W/m·K.

Fixing brackets

Guidance for specification option:

Insert requirement, consult manufacturer's literature for more information.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Mineral wool

Recyclability

Recyclable

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

2

Revit
-

2

Third party certifications

Certifire Certificate

Certifire Certificate

CF 563

QA Certificate

QA Certificate

Intertek US : WHI19-32944301 Iss. 7

Literature

Siderise CW-FB Curtain Wall Fire Board Technical Data v2.01

Siderise CW-FB Curtain Wall Fire Board Technical Data v2.01

Similar products from Siderise Group

Siderise BB-FB Balcony Bracket Cavity Barrier Kit

Siderise BB-FB Balcony Bracket Cavity Barrier Kit

Siderise CW-FS Firestop and CW-CB Cavity Barrier

Siderise CW-FS Firestop and CW-CB Cavity Barrier

Siderise EW Systems Cavity Barriers and Fire Stops for Masonry External Walls

Siderise EW Systems Cavity Barriers and Fire Stops for Masonry External Walls

Siderise TW Cavity Barrier and Firestop for Tops of Walls

Siderise TW Cavity Barrier and Firestop for Tops of Walls

Siderise TW-P Firestops for Profiled Decks

Siderise TW-P Firestops for Profiled Decks