Verified by manufacturer 3 months ago
SFP24 Aluminium Secret-Fix Flat Plank Panel - Vertical
CWCT Certificate
Certificate type
Slimwall™ secret-fix flat plank panel wall cladding system.
Wall cladding plank profiles. Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.
Slimwall™ SFP24 and SFP42 secret-fix flat plank panel wall cladding system.
Features and benefits:
System components:
Color | Other Guidance for specification option: Standard RAL Range; Contact APL for full details; Bespoke upon request Silver Guidance for specification option: Aluminium Manufacturer guidanceAluminium : Standard RAL Range; Contact APL for full details; Bespoke upon request Cor-Ten: Unweathered. |
Finish | Powder-coated Guidance for specification option: Class 1 or Class 2 Full RAL colour range and / or contact APL for additional finishes such as anodised-look Natural Guidance for specification option: Smooth mill-finish aluminium Unweathered Cor-Ten Anodized Guidance for specification option: Contact APL for details Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity) Painted Guidance for specification option: Aluminium with Armacoil™ HDP or Armacoil™HDP-HT (Subject to minimum quantity) Steel with APL PUF or PRISMA Manufacturer guidancePPC, Armacoil™ HDP, Armacoil™HDP-HT, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). PRISMA, Natural |
Material | Aluminium Cor-Ten Steel |
Shape | Other Guidance for specification option: Flat Plank Panel Rectangle |
Length | Bespoke Guidance for specification option: Maximum length 6 m. |
Width | Bespoke Manufacturer guidanceSFP42: Module 300-600 mm with joint size 3-20 mm. SFP24: Module 150-300 mm with joint size 3-20 mm. |
Height | Bespoke Manufacturer guidanceSFP24: 24mm deep SFP42: 42mm deep Bespoke heights also available |
Warranty description | 25 year |
Uniclass | |
CAWS | H31/120 Metal H92/120 Rainscreen cladding H31/10 Metal |
Liner sheets | |
Material | AP19 LPH Liner sheet.Guidance for specification option: Cladding rails. APL StrongBak™.Guidance for specification option: Long-span, non-combustible structural cladding system based upon Kassett construction principles. To be specified separately. Other.Manufacturer guidanceSFS/Blockwork substrate/Timber - refer to relevant manufacturer; Minimum FR-rated breather membrane required to outside face of P600 (APZ) where a fully-filled system is utilized. |
Primary fasteners | APL P191/HH fixing range. |
End and side laps | Minimum 75 mm; APL P191/HH fixing range at one per mid span.APL P103 + P108/VCT sidelap sealant range.P152 Flute Fillers. |
Air and vapour control layer | |
Material | AP19 LPH Liner sheet.Guidance for specification option: Cladding rails. APL StrongBak™.Guidance for specification option: To be specified separately. Other.Guidance for specification option: SFS/ blockwork substrate/ timber - refer to relevant manufacturer and insert requirements. Manufacturer guidanceMinimum FR-rated breather membrane required to outside face of P600 (APZ) where a fully-filled system is utilized. |
Fasteners | APL P191/HH fixing range.Guidance for specification option: For use with cladding rails. Other.Guidance for specification option: For use with SFS/ blockwork/ timber - refer to relevant manufacturer and insert requirements. |
Sealing | Cladding rails: As per Liner sheet; side laps sealed with two x runs of P108/VCT.Other.Guidance for specification option: For use with SFS/ blockwork/ timber - refer to relevant manufacturer and insert requirements. |
Spacers | Tritherm Spacer System℗ - fully-filled cavity (CWCT-tested) for use with cladding rails.Guidance for specification option:
Tritherm Spacer System℗ - fully-filled cavity (CWCT-tested) for use with SFS/ blockwork/timber.Tritherm Spacer System℗ - Ventilated Cavity SFS/ Blockwork / Timber substrateGuidance for specification option: P618 Tophat, P665-ALU RWB, P546 Isopad, P157-ALU HH bracket, P754 + P785 horizontal ALU zed. Tritherm Spacer System℗ - Ventilated CavityGuidance for specification option: SFS/ blockwork/ timber substrates: P521/4 + P528/4 HH brackets with P546 Isopad thermal breaks, P759 vertical ALU "L" rail, P754 horizontal ALU zed. |
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance.Guidance for specification option: Contact manufacturer for details and insert details as required. |
Thermal insulation | A1-rated.Guidance for specification option: A1-rated, thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes; where fully-filled cavity, allow an extra 10% of cavity thickness for soft-type insulation to fill rear of panel:
Refer to the relevant U-value table in the supporting literature. |
Breather membrane | |
Material | Minimum fire-rated B-s2,d0. |
Joint sealant | As per membrane manufacturers recommendations. |
Cavity fire barriers | |
Horizontal barriers | As per cavity barrier manufacture requirements. |
Vertical barriers | As per cavity barrier manufacture requirements. |
External sheets | |
Material | Aluminium - solid.Aluminium - perforated.Guidance for specification option: Consult manufacturer for details of perforation size etc. |
Primary fasteners | APL 191/LP fixing for secret fix. |
Secondary fixings | N/A - "male" and "female" type joint. |
End and side laps | N/A - "male" and "female" type joint with gasket; GEX/F2 flashing at corners |
Wall glazing | Required.Not required. |
System accessories | APL System Flashings.APL Fixings (P191 & P192).APL Sealants as APL recommendations and to match profiles.P087 vertical drainage cover trim fixed to vertical APZ. |
Fixings | APL P191/HH range. |
Colour/ Finish: | Armacoil™ HDP. Guidance for specification option: Subject to minimum quantities. Insert colour required. Armacoil™ HDP-HT. Guidance for specification option: Insert colour required. Anodized. Guidance for specification option: Contact APL for details. Polyester powder-coated, class 1. Guidance for specification option: Insert colour/ finish required. Polyester powder-coated, class 2. Guidance for specification option: Insert colour/ finish required. Manufacturer guidanceInsert colour requirements. |
NominalThickness | 1.2–1.5 mm. |
Minimum bearing area | 50 mm. |
Liner Supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones.
|
Profile supports | Manufacturer guidanceSubject to loadings. Centres are to general areas only, closer at high load zones.
|
Orientation | Vertical. |
Recycled content (minimum) | Up to 95%. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | % Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
APL Tritherm Spacer System℗ - Aluminium - Data Sheet
APL Tritherm Steel Spacer System - Cladding - System Summary
APL Tritherm Spacer System℗ - STEEL - Data Sheet
U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails
U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork
U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails
U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork
APL Armacoil™HDP + HDP-HT - Product Brochure
APL Armacoil™HDP-HT - Product Brochure
APL Liner Profiles - Roofing & Cladding - System Summary
APL StrongBak™ - Cladding - System Brochure
APL Cladding Systems Brochure
APL Slimwall™ - Cladding - System Brochure
APL Slimwall™ - System Summary
APL StrongBak™ - System Summary
APL AluE™ Tritherm™ Aluminium Spacer System - Cladding - System Summary