Verified by manufacturer 13 days ago
ROOFTRAK® IFP-BI - inverted hot melt roof
ISO 9001 Quality Management
Certificate type
ROOFTRAK® IFP-BI integrated fixing point system for handrail and balustrade applications on warm roof constructions.
Typical uses include connecting balustrade supports to flat warm roofs.
Suitable for use with the following roof covering types:
ROOFTRAK® IFP-BI integrated fixing point system for handrail and balustrade applications on warm and inverted roof constructions. The IFP-BI can be used in both horizontal (flat roof) and vertical (parapet wall) applications.
Features and benefits:
Color | Grey |
Finish | Coated |
Material | Steel Stainless steel |
Length | 375 mm |
Width | 225 mm |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | C41/665 Lateral restraint straps C41/665 Lateral restraint straps H51/580 Fixing E42/330 Anchor bolts H40/770 Fixing |
Material | Stainless steel.Guidance for specification option: Anchor point only, other materials defined in properties below. Weathering flange material to match main roof weathering system. |
Main roof weathering material | APP modified bitumen membrane. EPDM roofing membrane. GRP roof coverings. Liquid applied roof coatings. PIB roofing membrane. Manufacturer guidanceSelect material for weathering flange from the list below, or consult manufacturer and insert appropriate details. |
Balustrade connection plate | Not required. Mild steel. Stainless steel. |
Accessories | None. Cap nut, IFP-CN. Guidance for specification option: Low profile fixing designed specifically for use with the IFP. Allows the use of M10 studding for where the IFP requires bolting to the structure. The rounded low profile cap nut will not damage the roofing membrane that sits over it.
Toggle fixing, IFP-TG. Guidance for specification option: For use in conjunction with the IFP-CN cap nut and M10 studding to secure the IFP products to the building structure. Suitable where the underside of the roof deck is not accessible or where the roof deck does not provide adequate pullout values using screw type fixings.
|
Flange size | APP/ SBS modified bitumen membranes: 525 x 675 mm. Single-ply membranes: 425 x 575 mm. |
Anchor type: | 304 stainless steel, machined finish. Guidance for specification option: Standard. 316L stainless steel. Guidance for specification option: For marine environments. |
Fixing plate | Base section: mild steel, polyester powder-coated (PPC) finish; 225 x 375 mm. |
Height | Variable to suit insulation depth. |
Type | IFP-BI. Guidance for specification option: Designed for use on inverted flat roof constructions where it is fixed directly to the supporting roof deck below the insulation providing a connection point for balustrade supports. Typical use: Connecting balustrade supports to a flat roof where resistance to a turning moment is required. Designed for warm or inverted roof constructions on concrete or timber substrates. |
Thermal break | 5 mm HDPE. |
Insulation | Internal: PIR. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Steel Stainless steel |
Recyclability | Recyclable at end of life. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 50 % |
Expected Life | 30 year |
ROOFTRAK Integrated fixing point system
Why use the ROOFTRAK system for Solar PV?
ROOFTRAK IFP-BI vertical Tech Data Sheet
ROOFTRAK IFP-BI for warm roof Tech Data Sheet
ROOFTRAK IFP-BI for inverted membrane roof Tech Data Sheet
ROOFTRAK IFP-BI for inverted hot melt Tech Data Sheet
ROOFTRAK IFP-BI-T for warm roof Tech Data Sheet