This site uses cookies to store information on your computer. Learn more about these cookies, and how to opt out of them. Find out more
Verified by manufacturer 2 months ago
BBA Agrément Certificate
Certificate type
QA Certificate
Certificate type
Drained and back ventilated rainscreen cladding system.
External rainscreen cladding.
Suitable for for use over:
Grooved rainscreen cladding system comprising panels made in mineral composite, designed for use as a decorative and protective facade over external walls of buildings.
The panels offer a choice of different finishes and colours in different sizes. The system includes the panels and the horizontal rails only. Primary subframe not included.
Technical characteristics:
FinishIncludes Moon, Papyrus, Rhodes, Riven, Shell, Taïga and Urba finishes. | Gloss Matt |
Material | Mineral Composite |
Shape | Rectangle Square |
SizeBespoke thickness possible | and sub-multiples |
Length | Bespoke |
Width | Bespoke |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Product range |
Thermal insulationInsert requirements (specify separately if required) or omit. | - |
Breather membrane | - |
MaterialInsert requirements (specify separately if required) or omit. | - |
FastenersInsert requirements (specify separately if required) or omit. | - |
Secondary support structureSee also Horizontal rail type, Corner and System accessories for detailed options. | With Backing structure (CWB), horizontal installation.Without Backing structure (CWoB), horizontal installation.With Backing structure (CWB), vertical installation.Without Backing structure (CWoB), vertical installation. |
Cavity fire barriers | - |
HorizontalInsert requirements (specify separately if required) or omit. | - |
VerticalInsert requirements (specify separately if required) or omit. | - |
Cladding panels | - |
Material | Polyester resin concrete.Panel size and finish specified separately below. |
Panel joints | Open 3 mm vertical joints using wedges after each panel along the horizontal rail. Horizontal: as per rails specified. |
RevealsConsult manufacturer's literature for further details. | Metallic.Acantha. |
Samples required | Product samples, mock-ups or prototypes. |
System accessoriesConsult manufacturer for further details as required. | Shore rail(s).Starter rail(s).High rail(s).Expansion rail(s).Finishing rail(s).Nail finishing rail(s).Top Hat traversing fixing (QFT).Top Hat reinforcement (QRQ4).At ground floor level, additional Top Hat reinforcement can be used to provide extra support for the impact resistance of the cladding. Other.Consult manufacturer for options and insert requirements. |
Panel sizePanel thickness: 14–16 mm; consult manufacturer for details. | Insert requirements or drawing reference/ schedule. Panels available 250–900 mm x 300–3000 mm. |
Panel finishConsult manufacturer for colour options and insert requirements where applicable. | Glossy. Smooth Matt. Moon. Papyrus. Rhodes. |
Colour | Refer to manufacturer's technical brochure and insert requirement. |
Weight | 36–43 kg/m² (approximate). Dependent on finish. |
Horizontal rail typeThickness: Rail: 1.8 mm; nib: 1.0 mm. | 3 mm. Mill finished. 13 mm. Anodized. 20 mm. Anodized. 40 mm. Anodized. |
Corners | Mitred edge panel. Pre-coloured aluminium profile. Consult manufacturer for options and insert requirements. Welded corner piece. |
Air gap | Nominal 50 mm. |
Country of material origin | France |
Country of product manufacture | France |
Acantha Product Sheet
BRE Global Assessment Report
BRE Global Assessment Report - Vetage Clip
BRE Global Classification Report
Carea Facade Portfolio
Carea Facade technical brochure
Classification of Accessories for Grooved Panels - Vertical Fitting
Classification of Accessories - Grooved Panels - Horizontal Fitting
Classification of Accessories - Interlocking Panels - With Backing Structure
Classification of Accessories - Interlocking Panels - Without Backing Structure
Classification of Reaction to Fire Performance in Accordance to NF EN 13501-1 (ARDAL / ACANTHA)
Implementation Guide for Grooved Panels - Horizontal fitting
Implementation Guide for Grooved Panels - Vertical Fitting
Bastille Opera – Paris Fr
Bethnal Green Road, London UK
Britannia Music Site, Ilford UK
Clarence Dock, Leeds UK
Glasgow College, Glasgow UK
Lecanuet Secondary School, Rouen FR
Merchant square, London UK
Mourinoux Tower, Asnières FR
New Hospital, Orléans FR
Northampton College UK
Northampton University Senate Building, UK
Spire Hospital, Manchester UK
The Gateway, Leeds (UK)
University of Hertfordshire, Hatfield UK
Victoria Point New Hotel, Ashford UK
Paul Eluard Secondary School, Montereau-Fault-Yonne FR
BBA Agrément Certificate
BBA Carea Grooved horizontal cladding system certificate 07/4429 Product Sheet 1
BBA Agrément Certificate
BBA Carea Grooved vertical cladding system certificate 07/4429 Product Sheet 2
QA Certificate
CSTB Technical Approval Grooved Carea Horizontal Fitting 2-16-1774
QA Certificate
CSTB Technical Approval Grooved Carea Vertical Fitting 2.2_14-1659