NBS Source
I'm a manufacturer

Rainscreen Cladding System with ACANTHA Grooved Panel - Drained and Back Ventilated

Verified by manufacturer 6 months ago

Carea Façade Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • QA Certificate

    QA Certificate

    Certificate type

  • EPD

    EPD

    Certificate type

Drained and back ventilated rainscreen cladding system.

Jump to:
+44 (0) 79178 88384 Website

Application

External rainscreen cladding.


Suitable for for use over:

  • Concrete.
  • Blockwork.
  • Brickwork.
  • Structural and lightweight steel framing.
  • Timber frame.
  • Curtain walling.

Description

Grooved rainscreen cladding system comprising panels made in mineral composite, designed for use as a decorative and protective facade over external walls of buildings.

The panels offer a choice of different finishes and colours in different sizes. The system includes the panels and the horizontal rails only. Primary subframe not included.


Technical characteristics:

  • Air gap: Nominal 50 mm.
  • Panel tolerances: ±1 mm in height, ±0.5 mm in length.
  • Reaction to fire: EN 13501-1: A2-s1, d0.
  • Wind resistance: 2.2 kN/m².
  • Impact resistance (to BS 8200): Standard: D; Reinforced: B.
  • Thermal conductivity: 1.65 W/m·K.
  • Bending strength: >26 MPa.
  • Resilience: >1.3 kJ/m².
  • Panels can be specified (separately) as stand-alone products if required.

General information

Finish

Smooth

Matt

Gloss

Other

Guidance for specification option:

Finishes include Shell, Moon, Rhodes, Urba, Riven, Glossy, Smooth Matt, Taïga, Papyrus, Fluted, Wood and Glass Paste.

Mineral

Show more

Material

Mineral

Composite

Shape

Rectangle

Square

Length

Bespoke

Width

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Product range

Carea grooved panels

Specification data - Drained and back-ventilated rainscreen cladding systems

Thermal insulation

-

Manufacturer guidance

Insert requirements (specify separately if required) or omit.

Breather membrane

-

Material

-

Manufacturer guidance

Insert requirements (specify separately if required) or omit.

Fasteners

-

Manufacturer guidance

Insert requirements (specify separately if required) or omit.

Secondary support structure

With Backing structure (CWB), horizontal installation.

Without Backing structure (CWoB), horizontal installation.

With Backing structure (CWB), vertical installation.

Without Backing structure (CWoB), vertical installation.

Manufacturer guidance

See also Horizontal rail type, Corner and System accessories for detailed options.

Cavity fire barriers

-

Horizontal

-

Manufacturer guidance

Insert requirements (specify separately if required) or omit.

Vertical

-

Manufacturer guidance

Insert requirements (specify separately if required) or omit.

Cladding panels

-

Material

Polyester resin concrete.

Guidance for specification option:

Panel size and finish specified separately below.

Panel joints

Open 3 mm vertical joints using wedges after each panel along the horizontal rail. Horizontal: as per rails specified.

Reveals

Metallic.

Acantha.

Manufacturer guidance

Consult manufacturer's literature for further details.

System accessories

Shore rail(s).

Starter rail(s).

High rail(s).

Expansion rail(s).

Finishing rail(s).

Nail finishing rail(s).

Top Hat traversing fixing (QFT).

Top Hat reinforcement (QRQ4).

Guidance for specification option:

At ground floor level, additional Top Hat reinforcement can be used to provide extra support for the impact resistance of the cladding.

Other.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Manufacturer guidance

Consult manufacturer for further details as required.

Panel size

Guidance for specification option:

Insert requirements or drawing reference/ schedule.

Panels available 250–900 mm x 300–3000 mm.

Manufacturer guidance

Panel thickness: 14–16 mm; consult manufacturer for details.

Panel finish

Glossy.

Smooth Matt.

Moon.

Papyrus.

Rhodes.

Show more

Manufacturer guidance

Consult manufacturer for colour options and insert requirements where applicable.

Colour

Guidance for specification option:

Refer to manufacturer's technical brochure and insert requirement.

Weight

36–43 kg/m² (approximate).

Guidance for specification option:

Dependent on finish.

Horizontal rail type

3 mm.

Guidance for specification option:

Mill finished.

13 mm.

Guidance for specification option:

Anodized.

20 mm.

Guidance for specification option:

Anodized.

40 mm.

Guidance for specification option:

Anodized.

Manufacturer guidance

Thickness: Rail: 1.8 mm; nib: 1.0 mm.

Corners

Mitred edge panel.

Pre-coloured aluminium profile.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Welded corner piece.

Air gap

Nominal 50 mm.

Samples required

Product samples, mock-ups or prototypes.

Sustainability data

Contains Red List materials

No

Country of material origin

France

Country of product manufacture

France

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

44 kg CO₂ eq/m²

Recyclability

At end of life, the product is disassembled by hand. Aluminium and steel from under-structure are recycled, at a rate of 90% and 83% respectively. Remainder is sent to landfill at 100%.

Third party certifications

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

BBA Carea Grooved horizontal cladding system certificate 07/4429 Product Sheet 1

BBA Agrément Certificate

BBA Agrément Certificate

BBA Carea Grooved vertical cladding system certificate 07/4429 Product Sheet 2

QA Certificate

QA Certificate

CSTB Technical Approval Grooved Carea Horizontal Fitting 2-16-1774

QA Certificate

QA Certificate

CSTB Technical Approval Grooved Carea Vertical Fitting 2.2_14-1659

EPD

EPD

EPD for CAREA Acantha facade panel

Literature

Acantha Product Sheet

Acantha Product Sheet

BRE Global Assessment Report

BRE Global Assessment Report

BRE Global Assessment Report - Vetage Clip

BRE Global Assessment Report - Vetage Clip

BRE Global Classification Report

BRE Global Classification Report

Carea Facade Portfolio

Carea Facade Portfolio

Carea Facade technical brochure

Carea Facade technical brochure

Classification of Accessories for Grooved Panels - Vertical Fitting

Classification of Accessories for Grooved Panels - Vertical Fitting

Classification of Accessories - Grooved Panels - Horizontal Fitting

Classification of Accessories - Grooved Panels - Horizontal Fitting

Classification of Accessories - Interlocking Panels - With Backing Structure

Classification of Accessories - Interlocking Panels - With Backing Structure

Classification of Accessories - Interlocking Panels - Without Backing Structure

Classification of Accessories - Interlocking Panels - Without Backing Structure

Classification of Reaction to Fire Performance in Accordance to NF EN 13501-1 (ARDAL / ACANTHA)

Classification of Reaction to Fire Performance in Accordance to NF EN 13501-1 (ARDAL / ACANTHA)

Implementation Guide for Grooved Panels - Horizontal fitting

Implementation Guide for Grooved Panels - Horizontal fitting

Implementation Guide for Grooved Panels - Vertical Fitting

Implementation Guide for Grooved Panels - Vertical Fitting

Case studies

Bastille Opera – Paris Fr

Bastille Opera – Paris Fr

Bethnal Green Road, London  UK

Bethnal Green Road, London UK

Britannia Music Site, Ilford UK

Britannia Music Site, Ilford UK

Clarence Dock, Leeds UK

Clarence Dock, Leeds UK

Glasgow College, Glasgow UK

Glasgow College, Glasgow UK

Lecanuet Secondary School, Rouen FR

Lecanuet Secondary School, Rouen FR

Merchant square, London UK

Merchant square, London UK

Mourinoux Tower, Asnières FR

Mourinoux Tower, Asnières FR

New Hospital, Orléans FR

New Hospital, Orléans FR

Northampton College UK

Northampton College UK

Northampton University Senate Building, UK

Northampton University Senate Building, UK

Spire Hospital, Manchester UK

Spire Hospital, Manchester UK

The Gateway, Leeds (UK)

The Gateway, Leeds (UK)

University of Hertfordshire, Hatfield UK

University of Hertfordshire, Hatfield UK

Victoria Point New Hotel, Ashford UK

Victoria Point New Hotel, Ashford UK

Paul Eluard Secondary School, Montereau-Fault-Yonne FR

Paul Eluard Secondary School, Montereau-Fault-Yonne FR