NBS Source
I'm a manufacturer
Compare variants

QuadCore Louvre Wall Panel System

Verified by manufacturer 3 months ago

45 mm Core Thickness

Kingspan Insulated Panels Variant:
Third party certifications:
  • FM Approved

    FM Approved

    Certificate type

  • DoP

    DoP

    Certificate type

Secret-fix steel-faced, QuadCore insulated wall panel system with distinctive louvre profile.

Jump to:
+44 (0)1352 716440 Website

Application

Suitable for vertical and horizontal applications.

Description

Environmental:

  • Kingspan Insulated Panels produced in the UK and Ireland are certified to BES 6001 (Framework Standard for the Responsible Sourcing of Construction Products) ‘Good’. QuadCore® Insulated Panel systems have Environmental Product Declarations in accordance with the requirements of EN 15804 + A2: 2019. 
  • Facilities located in Kingscourt, Holywell and Sherburn generate renewable energy onsite which contributes to that sites energy mix.
  • Kingspan Insulated Panels procure steel that is made from 15 – 25% recycled content. Kingspan insulated panels directly contribute to BREEAM® / LEED® credits. Recycled content calculations are available for all QuadCore products via technical services.
  • To access the EPD for QuadCore Louvre Wall Panel System, please click here (https://www.epdhub.com/).


Kingspan QuadCore:

  • QuadCore is a self-blended, micro cell structured, insulation core unique to Kingspan that delivers the highest performance of any closed cell insulation core across four factors: fire, thermal, environmental & longevity.
  • The QuadCore insulation used in QuadCore Louvre Wall Panels has a thermal conductivity value of 0.018W/m.K.


Quality and Durability:

Kingspan insulated panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with:

  • BS EN ISO 14001 panels are manufactured under Environmental Management System Certification.
  • BS EN ISO 9001 standard, ensuring long term reliability and service life.
  • BS EN ISO 50001 Energy Management System Certification.
  • BS EN ISO 45001 Occupational Health and Safety Certification.
  • BS EN ISO 37301 Compliance Management Systems
  • CE marked to BS EN 14509: 2013.


Certification and Testing:

Reaction to Fire:

QuadCore Louvre Wall Panel is classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) EN 13501-1: 2018 under the certified name AWP Product Family when using the following internal liners:

  • CLEANsafe 15, CLEANsafe 25, CLEANsafe 55, CLEANsafe 120 and AQUAsafe 55.


Please contact Kingspan Tech-eXchange for information relating to the external face.


Insurer Approvals:

QuadCore Louvre Wall Panels are tested to LPS 1181 Part 1: Issue 1.2 Requirements and tests for built-up cladding and sandwich panel systems for use as the external envelope of buildings certified to:

  • LPS 1181-1 Grade EXT-B under the certified name Benchmark Louvre DW for thicknesses 45–150 mm.
  • FM 4880 approval standard for class 1 fire rating of building panels or interior finish materials for thicknesses 45–150 mm and panel widths of 1000 mm.
  • FM 4881 approval standard for class 1 exterior wall systems for thicknesses 45–150 mm and panel widths of 1000 mm.
  • FM 4882 approval standard for class 1 interior wall and ceiling materials or systems for smoke sensitive occupancies for thicknesses 45–150 mm and panel widths of 1000 mm.


FM approvals are subject to the following certified names:

  • For 1000 mm widths: KS1000LV. 


Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance. 


Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.


Fire Resistance:

Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project specific details.


Kingspan Tech-eXchange:

Kingspan Tech-eXchange is our dedicated team supporting you during the conception, design and installation of your project using our building envelope solutions, Kingspan Tech-eXchange supports our customers using the latest modelling and design software packages.


QuadCore® Assured System Warranty:


  • 25 years insurance backed thermal performance.
  • 25 years insurance backed fire performance .
  • 25 years structural performance.
  • 25 years environmental performance.
  • Up to 40 years coating performance.
  • 25 years warranty on system accessories*.


*Please contact Kingspan Tech-eXchange or refer to the ‘Quadcore Assured’ brochure for a list of accessories covered by Kingspan.


Kingspan Planet Passionate:

Planet Passionate is Kingspan’s ambitious 10 year global sustainability programme which aims to impact three big global issues

  • Climate change.
  • Circularity.
  • Protection of our natural world.

By setting ourselves challenging targets in the areas of energy, carbon, circularity and water, we aim to make significant advances in the sustainability of both our business operations and our products.

General information

Material

Steel

Warranty description

25 year

Guidance for specification option:

  • Insurance backed thermal performance.
  • Insurance backed fire performance .
  • Structural performance.
  • Environmental performance.
  • System accessories*.


*Please contact Kingspan Tech-eXchange or refer to the ‘Quadcore Assured’ brochure for a list of accessories covered by Kingspan.

40 year

Guidance for specification option:

Up to 40 years coating performance.

Manufacturer guidance

QuadCore® Assured System Warranty.

Uniclass

Ss_25_20_14_54 Metal insulating sandwich panel cladding systemsPrimary

CAWS

H43/10 Metal insulating sandwich panel

H43/120 Metal insulating sandwich panel

Product range

Architectural facades / Wall panel systems

Specification data - Metal insulating sandwich panel cladding systems

Cladding panels

-

Panel type

QuadCore Louvre, 45 mm.

Guidance for specification option:

Core insulation: QuadCore, 45 mm.

Overall thickness: 63 mm.

U-value: 0.43 W/m²·K.

Manufacturer guidance

Additional specification information for QuadCore Louvre panel types is available and is classified against the Carbon steel insulating sandwich panels category.

Panel fasteners

Grade 316 austenitic stainless steel self-drilling, self-tapping primary fasteners with non-ferrous EPDM backed washer, 8 mm hexagonal heads.

Grade 304 austenitic stainless steel self-drilling, self-tapping primary fasteners with non-ferrous EPDM backed washer, 8 mm hexagonal heads.

Side laps sealing

Factory applied weather seal set in rebate.

End laps sealing

Kingspan AWP filler and non-setting gun-grade, site applied at the end of each panel where flashings pass over the joint. Bridging seal across panel joint in line with AWP filler and internal air seal to be non setting gun-grade. Internal face of panel to be air sealed to perimeter supports/ flashing using 20 x 9 mm PVC foam tape.

Side lap stitching fasteners

Secondary fasteners to be grade 316 austenitic stainless steel screw and washer, low profile painted head.

Secondary fasteners to be grade 304 austenitic stainless steel screw and washer, low profile painted head.

End lap stitching fasteners

Secondary fasteners to be grade 316 austenitic stainless steel screw and washer. Low profile painted head.

Secondary fasteners to be grade 304 austenitic stainless steel screw and washer. low profile painted head.

Continuity thermal insulation

PIR insulation board to be installed in certain details to ensure thermal continuity. Fill any gaps with fire-rated canister insulation.

Guidance for specification option:

Consult with manufacturer for further details.

Panel joints

-

Horizontal

Male and female joint.

Vertical

Butt joint.

Glazing

Kingspan Day-Lite Klick.

Guidance for specification option:

To be specified separately.

Manufacturer guidance

Wall light solutions are to be specified fully elsewhere - see Kingspan Light + Air or consult manufacturer for details.

System accessories

Mechanically fixed fin feature flashing.

Sustainability data

Material

Steel

Third party certifications

FM Approved

FM Approved

LPCB Certificate of Product Approval - 260F

DoP

DoP

Declaration of Performance - QuadCore Louvre Wall Panel 0124

Literature

QuadCore® Louvre Wall Panel Datasheet

QuadCore® Louvre Wall Panel Datasheet