NBS Source
I'm a manufacturer

Proteus HR - Metal Rainscreen Cladding

Verified by manufacturer 2 months ago

Proteus Facades Third party certifications:
  • BS EN 13501-1

    BS EN 13501-1

    Certificate type

A honeycomb rainscreen system with recessed joints in steel, aluminium, zinc, stainless steel, copper alloys and other materials.

Jump to:
BOS
+44 (0)151 5455075 Website

Application

Can be installed on to any type of wall construction.

Description

Proteus HR is an integrated modular rainscreen cladding system that offers a flat façade with recessed joints in steel. Our Proteus HR rainscreen cladding system is

available in a wide range of materials and finishes, including aluminium, zinc, stainless steel, copper alloys and various other options.


Proteus HR consists of an aluminium honeycomb core that has been structurally bonded between two thin gauges of lightweight metal skin. Each panel is supported by the unique Proteus system of aluminium carriers and ancillary components, which can be installed on any type of wall construction.


The naturally optimised structure of Proteus HR’s honeycomb core delivers maximum compression and shear resistance with minimal material. This means that lightweight, economic panel skins can be used to minimise the load transferred to the main structure and reduce overall material requirements compared to a conventional metal rainscreen panel.


Benefits:

  • Large-format panels
  • Each panel can be individually adjusted and demounted.
  • High resistance to impact, thermal bow and ‘oil canning.’
  • Flat, curved, corner and soffit panels are available.
  • A range of panel sizes, thicknesses and metal finishes are available.
  • All panels are assembled at our factory and pre-finished for rapid installation.
  • Proteus HR is Fully tested and compliant with CWCT standards.
  • Tested to EN13501 achieving A2-s1, d0 or A2-s2, d0 subject to metal finish.
  • Composite construction can be broken down and fully recycled.

Construction:

  • Backing wall.
  • Vapour control layer (VCL).
  • Insulation.
  • Panel support system.
  • Panels.
  • Panel joints.


Standards/ Certifications:

  • CWCT.
  • EN 13501.
  • ISO 9001.
  • ISO 14001.
  • ISO 45001.

General information

Color

Gold

Silver

Black

White

Grey

Show more

Manufacturer guidance

Project specific - wide range of materials and colour choices depending on required finish.

Finish

Anodized

Powder-coated

Brushed

Coated

Galvanized

Show more

Manufacturer guidance

Various panel facings are available.

Material

Metal

Aluminium

Steel

Copper

Zinc

Show more

Manufacturer guidance

A range of materials available providing a range of finishes including PPC Aluminium, PVdF Aluminium, Anodized Aluminium, Copper, Zinc, Stainless Steel, Corten, Pre Coated Steel.

Shape

Rectangle

Square

Triangle

Rhombus

Trapezoid

Show more

Manufacturer guidance

Can be modular, flat or curved.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Guidance for specification option:

Warranty on the product finish will be dependent on location and subject to a questionnaire - consult manufacturer for details.

Extended warranties are available.

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Rainscreen cladding system design.

Thermal insulation

Insulation to be specified by others.

Guidance for specification option:

Insulation to be specified by others. A full range of bracket sizes available to accommodate the specified thickness of insulation.

Secondary support structure

Fully adjustable aluminium support system and ancillary components.

Guidance for specification option:

Suitable for both refurbishment and new build projects.

Cavity fire barriers

-

Horizontal

Horizontal cavity barriers by others.

Guidance for specification option:

As specified by a fire engineer.

Vertical

Vertical cavity barriers by others.

Guidance for specification option:

As specified by a fire engineer.

Cladding panels

-

Material

Aluminium.

Guidance for specification option:

Material width: 1000, 1250, 1500, 2000 mm. Maximum panel width: 960, 1210, 1460, 1960 mm. 1.5 mm thickness.

Copper.

Guidance for specification option:

Material width: 670, 1000 mm. Maximum panel width: 630, 960 mm.

Stainless steel.

Guidance for specification option:

Material width: 1000, 1250 mm. Maximum panel width: 960, 1210 mm. 0.8 mm thickness.

Weathering steel.

Guidance for specification option:

Material width: 1000, 1250 mm. Maximum panel width: 960, 1210 mm. 1 mm thickness.

Zinc.

Guidance for specification option:

Material width: 670, 1000 mm. Maximum panel width: 630, 960 mm. 0.7 mm thickness.

Manufacturer guidance

Finish as specified, consult manufacturer for details.

Panel joints

15 mm vertical and horizontal baffled joints.

Guidance for specification option:

Other joint sizes available on request.

Reveals

Typical opening reveals are shown in standard Proteus HR system details.

Manufacturer guidance

Bespoke details available to suit project requirements.

System accessories

Not required.

Extruded aluminium components.

Guidance for specification option:

Consult manufacturer, suitable for various applications.

Internal and external corners.

Curved panels.

Shaped panels.

Window reveals.

Door reveals.

Copings.

Base flashings.

Colour

Gold.

Silver.

Black.

White.

Grey.

Show more

Core fire rating

To EN 13501-1, Class A2-s1, d0.

To EN 13501-1, Class A2-s2, d0.

Thickness

Nominal thickness 27 mm subject to base material thickness.

Samples required

Finish samples.

System samples.

Sustainability data

Country of product manufacture

United Kingdom

Recyclability

Metal products can be broken down and recycled

Manufacturer guidance

All materials, other than adhesives, can be recycled at end of life.

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

4

Revit
-

4

Third party certifications

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Anodised Aluminium

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Brass

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Bronze

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Copper

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR PPC Steel

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Stainless Steel

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Weathering Steel

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR Zinc

BS EN 13501-1

BS EN 13501-1

Fire classification EN13501-1 - Proteus HR PPC Aluminium

Literature

Proteus HR Rainscreen Cladding Brochure

Proteus HR Rainscreen Cladding Brochure

Case studies

Granite Wharf, Greenwich, London

Granite Wharf, Greenwich, London

St Catherine’s College, Ainsworth Centre, Oxford

St Catherine’s College, Ainsworth Centre, Oxford

Durham University

Durham University

East London Line Stations, London

East London Line Stations, London

Grange University Hospital

Grange University Hospital

Institute of Physics, London

Institute of Physics, London

Mulberry Park School and Community Hub

Mulberry Park School and Community Hub

NTU Dryden Enterprise Centre

NTU Dryden Enterprise Centre

No.1 Hardman Street, Manchester

No.1 Hardman Street, Manchester

Record Hall, Hatton Square, London

Record Hall, Hatton Square, London

Whitechapel Station

Whitechapel Station

Lords Cricket Ground Compton and Edrich Stand

Lords Cricket Ground Compton and Edrich Stand

University of Sheffield Energy Centre

University of Sheffield Energy Centre

Spanish City, Whitley Bay

Spanish City, Whitley Bay