Verified by manufacturer 4 months ago
BBA Agrément Certificate
Certificate type
Robust Type A, pre-applied, fully bonded, gas-resistant waterproofing membrane for use in below ground, reinforced concrete structures.
A waterproofing membrane, which mechanically bonds to poured cast in situ concrete, remaining in place if settlement of the substrate occurs. A polyethylene membrane faced with a bonded complex cell mesh, allowing poured concrete to interlock with the membrane.
Features and benefits:
Color | Grey |
Material | Polyethylene |
Length | 30000 mm |
Width | 1270 mm |
Warranty description | Manufacturer guidanceA project specific warranty document for an agreed period for products supplied in accordance with a detailed specification document is available on request. |
Uniclass | |
CAWS | J40/130 Loose-laid plastics or rubber sheet oversite damp-proofing J40/30 Loose-laid plastics or rubber sheet oversite damp-proofing |
Material | Polyethylene (PE). |
Purpose | Waterproofing below ground concrete structures. |
Standard | To EN 13967. |
Performance characteristics | |
Tensile strength (minimum) | To EN 13967 Longitudinal >10.0 N/mm² Transverse >8.0 N/mm². |
Tear resistance | To EN 13967, Longitudinal >500 N. |
Elongation to break | To EN 13967, Longitudinal >300%, Transverse >200%. |
Resistant to underground gases | Methane, radon and carbon dioxide. |
Fire performance | To EN ISO 11925-2, Pass. |
Third-party certification | British Board of Agrément (BBA) Certificate. |
Form | Cell mesh bonded to a blended polyethylene and polypropylene membrane. |
Root inhibitor | Manufacturer guidanceResistance to roots - PD CEN/TS 14416:2014. |
Physical properties | |
Colour | Grey. |
Dimensions | |
Thickness (minimum) | 4–5 mm.Guidance for specification option: Overall thickness. Membrane thickness: 0.8 mm. |
Width (minimum) | 1.27 m. |
Roll length (minimum) | 30 m. |
Sealant tape | Not required. Proofex Detail Strip. Guidance for specification option: A reinforced double sided waterproof adhesive tape for sealing and jointing roll ends, cut edges and wall to floor detailing. |
Puncture resistance | 600 N. |
Adhesion | 74 N per 50 mm (Concrete cast against grid and cured for seven days. Peel adhesion tested at 50 mm/minute at 20ºC.) Manufacturer guidancePeel adhesion to concrete (BS 4254 mod) |
ShearStrength | Joints with selvedge: 377 N. Joints with Proofex Detail Strip joint sealant: 506 N. Manufacturer guidance(MOAT 27:5.2.2) |
Joints | Surfaces: Clean and dry beyond full width of joint. Laps: Edge laps 75 mm. End laps, butt jointed and taped. |
Material | Polyethylene |