NBS Source
I'm a manufacturer

Profiles XL FireSmart Plus System - Warm Roof / Torch On / Partial Bond / Heated / PIR - System Number 13

Verified by manufacturer 4 months ago

BMI Group UK Ltd

Reinforced bitumen membrane warm roof system based around the Profiles XL FireSmart Plus mineral capsheet and Thermazone Roofboard insulation.

Jump to:
+44 (0)1908 015760 Website

Application

Reinforced bitumen membrane warm roof system for use above non-combustible substrates in refurbishment and new build projects.

Description

Reinforced bitumen membrane warm roof system based around the Profiles XL FireSmart Plus mineral capsheet and Thermazone Roofboard insulation.


Features and benefits:

  • For use above non-combustible substrates in refurbishment or new build projects.
  • Range of insulation thicknesses available.
  • Wide range of accessories available.
  • Manufacturer offers a design and specification service (recommended that they are consulted early in the design process).
  • Part of a range of FireSmart based systems (others specified separately).

General information

Color

Grey

Guidance for specification option:

Charcoal or blue/grey.

Blue

Guidance for specification option:

Blue/ grey.

Green

Brown

Manufacturer guidance

To match field sheet, consult manufacturer for details.

Finish

Mineral

Material

Bitumen

Guidance for specification option:

Polyester reinforced styrene butadiene styrene (SBS) modified.

Polyisocyanurate (PIR)

Guidance for specification option:

Insulation.

Manufacturer guidance

See specification for other materials.

Shape

Other

Length

Bespoke

Width

Bespoke

Warranty description

30 year

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Siplast Primer.

Guidance for specification option:

Low viscosity priming solution consisting of elastomeric bitumen and hydrocarbon solvent.

  • Colour: Black.
  • Coverage rate: 3–11 m² per litre.
  • To be applied by brush or roller.
  • Application rate: 0.1–0.3 L/m².
  • Application limits: 5–30°C.
  • Drying time: 1–3 hours.
  • Available in container sizes of 25 L.

Skirtings and vertical work

As Horizontal work.

Air and vapour control layer

-

Type

Profiles Vapour Vent XL.

Guidance for specification option:

Glass reinforced SBS-modified bitumen membrane with bitumen bonding stripes on the upper surface.

  • Independently site and laboratory tested by the British Board of Agrément and awarded BBA certificate number 09/4645, Products Sheet 4.
  • CE marked.
  • Upper surface: Silica sand with SBS-modified bitumen stripes with thermofusible film.
  • Lower surface: Heat-activated self-adhesive SBS-modified bitumen with release sheet.
  • Type of reinforcement: Glass, 80 g/m².


Characteristics:

  • Length, to BS EN 1848-1: 7.5 m.
  • Width (including selvedge), to BS EN 1848-1: 1 m.
  • Straightness, to BS EN 1848-1: <20 mm/10m.
  • Effective thickness, to BS EN 1849-1: 3.5 mm.
  • Mass per unit area, to BS EN 1849-1: 3.5 kg/m².
  • Water tightness, to BS EN 1928 (A): Pass.
  • Water vapour resistance, to BS EN 1931: >6094 µ.
  • Reaction to fire, to BS EN 13501-1: Class E.
  • Tensile strength, to BS EN 12311-1: 840 N/50mm (MD); 550 N/50mm (TD).
  • Elongation, to BS EN 12311-1: 3.5% (MD); 3.8% (TD).
  • Dimensional stability, to BS EN 1107-1: ≤0.5.
  • Flexibility at low temperature, to BS EN 1109: ≤-10°C.
  • Flow resistance at elevated temperature, to BS EN 11071-7: ≥90°C.


Consult manufacturer's literature for tolerances.

Attachment

Torch-applied.

Manufacturer guidance

To be installed in accordance with current and relevant standards such as BS 8217, BS 6229 and BS 8000-4.


For further details consult the manufacturer's Flat Roofing Product Installation Guidelines or contact their technical services team.

Insulation

-

Type

Thermazone Roofboard insulation, 25 mm thick.

Thermazone Roofboard insulation, 30 mm thick.

Thermazone Roofboard insulation, 40 mm thick.

Thermazone Roofboard insulation, 50 mm thick.

Thermazone Roofboard insulation, 60 mm thick.

Thermazone Roofboard insulation, 70 mm thick.

Thermazone Roofboard insulation, 80 mm thick.

Thermazone Roofboard insulation, 90 mm thick.

Thermazone Roofboard insulation, 100 mm thick.

Thermazone Roofboard insulation, 110 mm thick.

Thermazone Roofboard insulation, 120 mm thick.

Thermazone Roofboard insulation, 140 mm thick.

Thermazone Roofboard insulation, 150 mm thick.

Thermazone Roofboard insulation, 160 mm thick.

Manufacturer guidance

  • Polyisocyanurate (PIR) rigid insulation faced on both sides with a mineralized glass tissue.
  • Boards size, to EN 822: 1200 x 600 mm.
  • Density: 32 kg/m³.
  • Compressive strength, to BS EN 826: 150 kPa (at 10% compression).
  • Thermal conductivity, to BS EN 13165: 0.024–0.027 W/m·K.
  • Thermazone Roofboard has been independently site and laboratory tested by the British Board of Agrément, and awarded BBA certificate number 15/5253 Products Sheet 3.

Tapered boards are also available.

Fixing

Heat activation of the lozenges to the upper surface of the VCL.

Waterproof covering

-

First layer

-

Type

TorchSafe TA Underlay.

Manufacturer guidance

Heat-activated/self-adhesive glass reinforced SBS-modified bitumen membrane with vapour control stripes. For use as an underlay/ base layer.

  • Upper surface: Thermofusible film with SBS bitumen adhesive and release sheet to overlap selvedge.
  • Lower surface: Silica sand with SBS-modified bitumen adhesive stripes with release sheet.
  • Material: SBS-modified bitumen.
  • Type of reinforcement: Glass fibre, 95 g/m².
  • Independently site and laboratory tested by the British Board of Agrément and awarded BBA certificate number 09/4645, Product Sheet 3.


Characteristics:

  • Length, to EN 1848-1: 10 m.
  • Width (including selvedge), to EN 1848-1: 1 m.
  • Straightness, to BS EN 1848-1: <20 mm/10m.
  • Mass per unit area, to BS EN 1849-1: 2.8 kg/m².
  • Effective thickness, to BS EN 1849-1: 3 mm.
  • Water tightness, to BS EN 1928 (B): Pass.
  • Tensile strength, to BS EN 12311-1: 450 N/50mm (MD); 450 N/50mm (TD).
  • Elongation, to BS EN 12311-1: 4% (MD); 3.5% (TD).
  • Dimensional stability, to BS EN 1107-1: ≤1%.
  • Flexibility at low temperature, to BS EN 1109: ≤-15°C.
  • Flow resistance at elevated temperature, to BS EN 1110: >105°C.


Consult manufacturer's literature for tolerances.

Attachment

Heat activation.

Self-adhesive.

Top layer

-

Type

Profiles XL FireSmart Plus Mineral Capsheet, charcoal.

Guidance for specification option:

Standard.

Profiles XL FireSmart Plus Mineral Capsheet, green.

Guidance for specification option:

Made to order, minimum order quantities may apply - consult manufacturer for details.

Profiles XL FireSmart Plus Mineral Capsheet, blue/ grey.

Guidance for specification option:

Made to order, minimum order quantities may apply - consult manufacturer for details.

Profiles XL FireSmart Plus Mineral Capsheet, brown.

Guidance for specification option:

Made to order, minimum order quantities may apply - consult manufacturer for details.

Manufacturer guidance

Polyester reinforced SBS-modified bitumen membrane with FireSmart fire retardant. For use as a torch-applied top sheet.

  • Upper surface: Mineral granules with thermofusible film to overlap selvedge.
  • Lower surface: Thermofusible PE film.
  • Material: SBS-modified bitumen.
  • Type of reinforcement: Polyester, 250 g/m².


Characteristics:

  • Length, to EN 1848-1: 5 m.
  • Width (including selvedge), to EN 1848-1: 1 m.
  • Mass per unit area, to BS EN 1849-1: 7.2 kg/m².
  • Effective thickness, to BS EN 1849-1: 5.5 mm.
  • Water tightness, to BS EN 1928 (B): Pass.
  • External fire performance, to EN 13501-5: BROOF(t4).
  • Tensile strength, to BS EN 12311-1: 900 N/50mm (MD/ TD).
  • Elongation, to BS EN 12311-1: 35% (MD/ TD).
  • Dimensional stability, to BS EN 1107-1: ≤0.5%.
  • Flexibility at low temperature, to BS EN 1109: ≤-20°C.
  • Flow resistance at elevated temperature, to BS EN 1110: >75°C.


Consult manufacturer's literature for tolerances.

Attachment

Torch-applied.

Detail work

-

Flashings

As Waterproof covering.

FormFlash lead-free roof flashing.

Guidance for specification option:

Insert requirements.

  • Roll length: 10 m; available in widths between 120 and 950 mm.
  • Lightweight, lead-free alternative for roof flashing. 50% lighter than Code 4 lead making it easier to handle and speedier to install.
  • FormFlash fixing clips included.
  • Smooth grey finish.

Not required.

Skirtings and upstands

TorchSafe TA Detailing Underlay and Profiles XL FireSmart Plus Mineral Capsheet.

Not required.

Welted drips

As Waterproof covering.

Not required.

Cover strips

As Waterproof covering.

Not required.

System accessories

None.

Roofgard GRP Edge Trims.

Guidance for specification option:

A range of perimeter trims is available in sizes B50, B100 or B150, with match internal and external corners available throughout.

Consult manufacturer and insert requirements.

Roofgard Universal Outlets.

Guidance for specification option:

Insert requirements.

Standard sizes: 50, 62, 80, 90 or 145 mm.

Leaf grate also available.

Roofgard Parapet Outlet.

Guidance for specification option:

Roofing outlet that complements built up roof systems allowing drainage of the roof through the parapet to an external hopper.


Insert requirements: 100 mm outlet opening as standard. Leaf grate, 45° chute and extension also available.

Roofgard Cable & Pipe Duct.

Guidance for specification option:

Provides a weatherproof sleeve for cables or tubes that penetrate through a flat roof

Thermazone Roofboard Angle Fillets.

Guidance for specification option:

High performance rigid urethane CFC-/ HCFC-free insulation board angles for transitioning between horizontal and vertical surfaces.

Roofgard Universal Cowled Telescopic Vents.

Literature

Siplast Primer Technical Data Sheet

Siplast Primer Technical Data Sheet

Profiles Vapour Vent XL Technical Data Sheet

Profiles Vapour Vent XL Technical Data Sheet

Thermazone Roofboard Technical Data Sheet

Thermazone Roofboard Technical Data Sheet

TorchSafe TA Underlay Technical Data Sheet

TorchSafe TA Underlay Technical Data Sheet

Profiles XL FireSmart Plus Torch-on Mineral Capsheet Technical Data Sheet

Profiles XL FireSmart Plus Torch-on Mineral Capsheet Technical Data Sheet

Profiles XL FireSmart Plus Systems - NBS

Profiles XL FireSmart Plus Systems - NBS

Similar products from BMI Group UK Ltd

FireSmart TorchSafe M.A. Roofing System

Power Elastomeric 250 Sand

Profiles Solo Roofing System

Profiles T.A. Warm Roofing System

Profiles T.A. Warm Roofing System

Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW

Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2