Single layer, reinforced bitumen membrane, warm deck roof covering.

Jump to:
0370 560 1000 Website

Application

  • Suitable for both new and refurbished roofs for use in conjunction with an underlay and capsheet to form fully bonded details.
  • The system is to be installed by a member of Icopal’s IMA-approved contractor network only.


Preparation:

  • Consult manufacturer for details of the preparation and priming of the intended roof structure and substrate and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips.

Description

Single layer, torch applied system of high performance elastomeric SBS modified bitumen membrane. The product has special stripes on the underside to provide a partial bond and allow dispersion of trapped vapour.


Features and benefits:

  • Elastotherm is a single layer torch-on mineral capsheet manufactured on a strong polyester reinforcement coated on both sides with SBS polymer modified bitumen.
  • The underside is finished with a specially blended bitumen stripe pattern and finished with thermofusible film.
  • The stripe pattern provides vapour equalization from entrapped moisture in the substrate avoiding blistering.
  • The upper surface is finished with slate granules providing a decorative appearance and UV resistance.
  • Offer a design and specification service (recommended that they are consulted early in the design process).

General information

Material

Bitumen

Guidance for specification option:

Styrene butadiene styrene (SBS) modified.

Polyester

Shape

Other

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/115 Single-layer reinforced bitumen membrane warm deck roof covering

J41/135 Single-layer reinforced bitumen membrane cold deck roof covering

Specification data - Reinforced bitumen membrane warm roof covering systems

Air and vapour control layer

-

Type

Not required.
Profiles T.A. VCL - Stripes.

Guidance for specification option:

Heat-activated self-adhesive bituminous vapour control layer.

Profiles Vapour-Vent XL.

Guidance for specification option:

Torch-applied vapour control layer with stripes on upper surface (for non-combustible substrates).

Insulation

-

Type

Thermazone Torch-on.

Guidance for specification option:

For partially bonded layers.

Waterproof covering

-

Top layer

-

Type

Profiles Solo Single-Layer Membrane.

Guidance for specification option:

Torch-applied layer with partial bond strips on underside and mineral finish top.

Manufacturer guidance

Top layer/ Capsheet.

System accessories

None.
Icopal Roofgard Outlet.
Icopal Roofgard Parapet Outlet.
Icopal Roofgard GRP Edge Trims.
Icopal Roofgard Cable and Tube Duct.
Icopal Roofgard Cowled Telescopic Vent.
Icopal Roofgard Lightning Conductor Pads.

Primer

Icopal S.A. Primer.

Guidance for specification option:

Quick drying primer for use with self-adhesive membranes.

Icopal Siplast Bitumen Primer.

Guidance for specification option:

Quick drying bituminous primer.

Capsheet

Profiles XL Mineral.

Guidance for specification option:

Torch applied capsheet.

FireSmart T.A. Detailing Capsheet.

Guidance for specification option:

Thermically-activated capsheet for combustible details.

Manufacturer guidance

Flashing and detail work.

Underlay

Profiles XL Sand.

Guidance for specification option:

Torch applied membrane.

Icopal T.A. Detailing Underlay.

Guidance for specification option:

Thermically-activated, self-adhesive membrane for combustible details.

Manufacturer guidance

Flashing and detail work.

Similar products from BMI Group UK Ltd

Power Elastomeric 250 Sand

Profiles T.A. Warm Roofing System

Profiles T.A. Warm Roofing System

Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW

Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / MW - System Number 12

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / MW - System Number 12

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / PIR - System Number 11

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / PIR - System Number 11