Verified by manufacturer 2 days ago
Powerlon® VCL 250
Powerlon® VCL 250 & VCL 170 are polyethylene-based vapour control layers with a mono-filament reinforcement scrim. Suitable for roof, wall and floor applications.
Powerlon® VCL 250 & VCL 170 AVCLs suitable for all roof and wall applications.
Storage and handling:
Installation:
Please see installation instructions for full details.
Overlaps:
Powerlon® VCL 250 & VCL 170 are polyethylene-based vapour control layers with a mono-filament reinforcement scrim to provide sufficient strength for roof, wall and floor installations. Air & vapour control layers (AVCLs) ensure that the building envelope is properly sealed to control ventilation and prevent heat loss in compliance with Building Regulations Part L. Installed on the warm side of insulation AVCLs prevent moisture within the building's warm air from reaching the insulation therefore protecting insulates from interstitial condensation.
Powerlon® AVCL membranes contribute to both BS 9250 for the airtightness in ‘a well-sealed ceiling’ and BS 5250 aiding the control of condensation within a roof space.
Features and benefits:
Color | Clear |
Material | Polyethylene |
Shape | Other Guidance for specification option: Roll. |
Length | 50000 mm |
Width | 2000 mm |
Uniclass | |
CAWS | H31/45 Air and vapour control membrane H31/261 Air and vapour control membrane H30/30 Air and vapour control membrane H30/261 Air and vapour control membrane J31/330 Air and vapour control layer J21/395 Air and vapour control layer J41/395 Air and vapour control layer J42/395 Air and vapour control layer P10/60 Air and vapour control layer P10/310 Air and vapour control layer H92/780 Air and vapour control layer |
Material | Polyethylene. |
Purpose | Vapour control layer. |
Standard | To EN 13984. |
Performance characteristics | |
Tensile strength (minimum) | To EN 12311-2, 585 N/50 mm (MD); 430 N/50 mm (CD). |
Tear resistance | To EN 12310-1, 250 N (MD); 300 N (CD).Manufacturer guidanceNominal. |
Elongation to break | To EN 12311-2, 14% (MD); 15% (CD).Manufacturer guidanceNominal. |
Water vapour resistance (minimum) | To BS 3177, 530 MN·s/g. |
Fire performance | To EN 13501-1, class F. |
Form | Reinforced.Manufacturer guidanceMono-filament reinforcement scrim. |
Physical properties | |
Colour | Clear. |
Weight (minimum) | 285 g/m². |
Dimensions | |
Width (minimum) | 2 m. |
Roll length (minimum) | 50 m. |
Roll weight | 29 kg. |
Water vapour transmission | To EN 1931/ EN 12572, 111 m. Manufacturer guidanceNominal. |
Material | Polyethylene |
FlameOUT® Block - FR Class B Flame-retardant AVCL - Air and Vapour Control Layer
Powerbase® Multigas Barriers - Protection Against CO2, Methane & Radon - Gas Barrier Membranes
Powerbase® VOC - Volatile Organic Compound & Hydrocarbon Gas Barrier Membrane - Vapour and Gas Barrier Membrane
Powerlon® UltraBlock - Thermo Reflective AVCL Vapour Control Layer - Thermo-Reflective Vapour Control Layer