NBS Source
I'm a manufacturer
Compare variants

Pilkington Fire Rated Horizontal (Roof/ Floor) Glass

Verified by manufacturer 2 months ago

Pyrostop® 30-401 (Horizontal (I/E))

Pilkington United Kingdom Limited Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

A range of Pilkington fire resistant products for horizontal applications, roof, floor and loaded floors.

Jump to:
Website

Application

  • Roofs.
  • Floors.
  • Load bearing floors.

Description

A range of Pilkington fire resistant products for horizontal applications, roof, floor and loaded floors. A bespoke range of tested solutions, classified from EW30 to REI60 for containing fire spread and for maintaining compartmentalization between buildings and floors.


Roof products are designed to prevent fire spread from the inside to the outside of the building, whilst floor products prevent fire spread between compartmentalized floors, allowing architectural design and maximizing the transmission of natural light whilst also (delete) performing the basic loaded functions of a normal floor.


These products are specifically designed and tested in horizontal form and cannot simply be a product that is tested in a vertical application and rotated through 90 degrees. Detailed design work may also be required to ensure product performance.


Features and benefits:

  • Complies with EN 1279-5.
  • Resistance to Fire (EN 13501-2): E/EW 30, EI 30 or EI 60.
  • Suitable for internal or external applications.
  • Ug-value (EN 673): 1.0—1.6 W/m²K.
  • Light transmittance (EN 410): 62—69%.

General information

Color

Clear

Finish

Laminated

Material

Glass

Shape

Square

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Uniclass

Pr_25_71_33_88 Thermally toughened glass sheetsPrimary

CAWS

H13/115 Structural glass assembly

H11/110 Curtain walling

H10/10 Patent glazing

H10/115 Patent glazing

Specification data - Thermally toughened glass sheets

Thickness

44 mm.

Body colour

Clear.

Performance requirements

-

Fire performance

30 minutes.

Light

Transmittance 63%.

Solar control

36%.

Thermal insulation

1.2 W/m²K.

Sound attenuation

40 (1,-4) dB.

Impact resistance

To BS EN 12600: 1(C)2 / 1(B)1.

Light reflectance

16%.

Reaction to fire

B-s1,d0.

TemperatureRange

-40 to +50°C.

Security

NPD / P2A.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Germany

Material

Glass

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

4.04 kg CO₂ eq/m²

Self declared

Recyclability

Glass panes can be re-melted on float line following correct separation from unit

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

20 %

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 - Quality Management System

Literature

Pilkington Fire Resistant Glass Range Brochure

Pilkington Fire Resistant Glass Range Brochure

Similar products from Pilkington United Kingdom Limited

Pilkington Optitherm™ S1 Plus Low Emissivity - Ultra low-emissivity glass

Pilkington Optitherm™ S1 Plus Low Emissivity - Ultra low-emissivity glass

Pilkington Pyroclear® Fire Resistant - Glazing sheet

Pilkington Pyroclear® Fire Resistant - Glazing sheet