NBS Source
I'm a manufacturer

PFC Corofil Open State Clip COSC

Verified by manufacturer 6 months ago

PFC Corofil Fire Stop Products

PFC Corofil Open State Clip COSC is a fire rated intumescent solution designed to react in a fire situation to seal within and in front of masonry support brackets.

Jump to:
+44 (0)20 8391 0533 Website

Application

PFC Corofil Open State Clip COSC is designed for use in combination with PFC Corofil Open State Barrier COSB 44 (1026) and provides an effective cavity fire barrier solution to ensure a continuous cavity barrier line around a masonry support system that also maintains drainage in normal conditions.

Description

PFC Corofil Open State Clip COSC is a 4mm thick intumescent strip riveted to a stainless steel plate shaped to fit within the opening of a Masonry Support Bracket. Combined with the PFC Corofil Open State Cavity Barrier COSB 44 (1026) installed between the brackets the two products create a horizontal open state cavity barrier system. The intumescent strip will react in a fire situation to close off the air gap between the barrier and the back of the external substrate.


Features and benefits:

• Tested to the general principles of EN 1363-1 and in accordance with ASFP TGD 19

• Provides fire resistance performance of up to 120 minutes integrity and insulation

• Suitable for cavity widths between 112.5mm and 287mm

General information

Color

Yellow

Material

Stainless steel

Intumescent

Polythene

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_20_85_09_82 Stainless steel cavity barrier bracketsPrimary

CAWS

F30/18 Cavity closers

F30/180 Cavity closers

P10/435 Ventilated cavity barriers

P10/77 Ventilated cavity barriers

Product range

Cavity Barriers

Specification data - Stainless steel cavity barrier brackets

Thickness

4 mm intumescent strip.

Cavity size

-

Manufacturer guidance

Suitable for cavity widths between 112.5 mm and 287 mm. Insert requirements.

Cavity barriers

PFC Corofil Open State Cavity Barrier COSB 44 (1026) - specified seperately.

Fire insulation

120 minutes to EN 1363-1 and TGD19.

Guidance for specification option:

Refer to manufacturer's literature for requirements.

Fire integrity

120 minutes to EN 1363-1 and TGD19.

Guidance for specification option:

Refer to manufacturer's literature for requirements.