NBS Source
I'm a manufacturer

PFC Corofil Cavity Fire Stop CCFS

Verified by manufacturer 17 days ago

PFC Corofil Fire Stop Products Third party certifications:
  • UL-EU Certified

    UL-EU Certified

    Certificate type

Full fill cavity barrier designed to be installed within building cavities between the façade and the inner structure.

Jump to:
+44 (0)20 8391 0533 Website

Application

PFC Corofil Cavity Fire Stop CCFS has been designed and tested to be installed within building cavities between the façade and the inner structure. It can be installed against SFS with a calcium silicate fibre cement board and masonry substrates in both horizontal and vertical orientations, and is suitable for cavity widths up to 600mm. PFC Corofil Cavity Fire Stop CCFS can also be installed in a masonry support system in cavities up to 450mm wide.

Description

PFC Corofil Cavity Fire Stop CCFS is cut to size to suit the cavity width and can be supplied as plain stone wool, foil encapsulated, or with an integral DPC. PFC Corofil Cavity Fire Stop CCFS has been tested to EN1366-4 and EN1363-1 TR031 and will provide up to 120 minutes fire integrity and insulation performance.


Features and benefits:

• Suitable for cavities up to 600mm

• Can be installed against SFS with a calcium silicate fibre cement board

• Can be installed against aerated concrete, concrete and masonry substrates

• Can be installed in a masonry support system

• Provides fire resistance performance of up to 120 minutes integrity and insulation

• 3rd party certification; UL-EU Certificate UL-EU-01231-CPR

General information

Material

Stone wool

Guidance for specification option:

High density rock mineral fibre.

Shape

Rectangle

Length

1000 mm

Width

Bespoke

Height

82 mm

100 mm

Uniclass

Pr_25_80_81_51 Mineral wool fire-stoppingPrimary

CAWS

P10/40 Insulation fitted betweenor to the face ofstuds

P12/360 Mineral wool rigid batts

P12/40 Mineral wool rigid batts

Product range

Cavity Barriers

Specification data - Mineral wool fire-stopping

Material

-

Type

Semi-rigid.

Fire performance

Up to two hours (120 minutes).

Guidance for specification option:

  • To EN 1366-4 and EN 1363-1 TR031.


Cavity size

Guidance for specification option:

Available to suit cavity widths up to 600 mm.

Third-party certification

UL-EU Certificate: UL-EU-01231-CPR.

Sustainability data

Material

Stone wool

Guidance for specification option:

High density rock mineral fibre.

Third party certifications

UL-EU Certified

UL-EU Certified

PFC Corofil Cavity Fire Stop CCFS - UL-EU Certificate: 01231-CPR

Literature

PFC Corofil Cavity Fire Stop CCFS - Datasheet

PFC Corofil Cavity Fire Stop CCFS - Datasheet

Case studies

Adelphi Wharf Case Study

Adelphi Wharf Case Study

Fortis Quay Case Study

Fortis Quay Case Study

Local Crescent Case Study

Local Crescent Case Study

Christie’s Hospital Case Study

Christie’s Hospital Case Study