Verified by manufacturer 2 months ago
CWCT Certificate
Certificate type
FPA
Certificate type
EPD
Certificate type
Optima TFC+ Discreet Cassette Rainscreen: Modernise with a sleek 20 mm joint, versatile installation, and Euroclass A1/A2 compliance. Economical, precision, efficiency, and discreet innovation.
The Optima TFC+ Discreet Through Fix Cassette Rainscreen is designed for a wide range of architectural cladding applications. Its versatility and innovative features make it suitable for both commercial and residential projects.
Optima TFC+ Discreet Through Fix Cassette Rainscreen Cladding System is a highly efficient and economical cladding system, offering a discreet alternative to traditional secret fix cladding. The system features a 20 mm joint both vertically and horizontally between panels, providing a sleek and modern aesthetic.
Features and benefits:
Versatile installation:
Precision fit and finish:
Efficient design:
Ventilated system:
Seamless integration:
Fire safety compliance:
Mechanical fixing methods:
Certifications:
Support and fixing system:
Note: Consult Sotech for information on structural restrictions, panel size, fastener type, and fixing frequency.
Color | Beige Black Blue Bronze Brown |
Finish | Anodized Powder-coated Brass Bright Brushed |
Material | Aluminium Stainless steel Copper Zinc Bronze |
Shape | Square Guidance for specification option: Standard rectangular and square flat panels. Rectangle Guidance for specification option: Standard rectangular and flat panels. Triangle Guidance for specification option: Available on request. Other Guidance for specification option: Other bespoke shapes such as specialist curving as requested. Manufacturer guidanceShapes provided by Sotech. |
Length | Bespoke Guidance for specification option: Sizes available on request Manufacturer guidanceSizes available on request |
Width | Bespoke Guidance for specification option: Sizes available on request Manufacturer guidanceSizes available on request |
Height | Bespoke Guidance for specification option: Sizes available on request Manufacturer guidanceSizes available on request |
Warranty description | Other Guidance for specification option: Dependant on specified finish and material. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Thermal insulation | Guidance for specification option: Full range of bracket zones to accommodate specified thickness of rockwool insulation. |
Breather membrane | |
Material | Guidance for specification option: By installer. |
Fasteners | Guidance for specification option: By installer. |
Secondary support structure | TFC+ bracket and rail system to take colour-coded fixings. |
Cavity fire barriers | |
Horizontal | Guidance for specification option: By others. Siderise tends to be used in our fire tests. |
Vertical | Guidance for specification option: By others. Siderise tends to be used in our fire tests. |
Cladding panels | |
Material | Aluminium: 2 mm; precoated PVdf or polyester.Aluminium: 2 and 3 mm; polyester powder-coated (PPC) to BS 6496.Aluminium: 2 and 3 mm; anodized (25 micrometre minimum) to BS 3987.Aluminium: 2 and 3 mm; PVdf 70/30 two-coat system (25 micrometre) to AAMA605.Aluminium: 2 and 3 mm; PVdf 70/30 three-coat system (40 micrometre) to AAMA605.Aluminium composite material (ACM): 4 mm. A1 and A2, s1-d0, only.Copper: 1.5 mm; natural finish, and pre-patinated.Stainless steel (rigidized): 1.2 and 1.5 mm; natural, polished or patterned finish.Weathered zinc. |
Reveals | Guidance for specification option: Typical window reveals as TFC+ details. |
System accessories | None.Column casing.Coping system.Corner profile - external.Corner profile - internal.Fascia system including bull-nose.Head profile.Jamb profile.Window sill profile. |
Thickness | 1.2 mm. 1.5 mm. 2 mm. 3 mm. 4 mm. |
Contains Red List materials | No |
Country of material origin | Europe Guidance for specification option: One of several places material is sourced. Manufacturer guidanceMultiple places for material origins. |
Country of product manufacture | Europe Guidance for specification option: One of several places for manufacture. Manufacturer guidanceMultiple countries for product manufacture. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 60.2 kg CO₂ eq/m² Guidance for specification option: Polyester powder-coated (PPC) aluminium. |
Recyclability | 95% recyclability for aluminium Guidance for specification option: Generally prime aluminium. Manufacturer guidanceGenerally prime aluminum. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % Guidance for specification option: Up to 20% recycled content for aluminium sheet, and up to 75% recycled content for extruded aluminium. These values could vary depending on where the material is sourced. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 2 |
BRE Global Test Report BS8414-2 Optima TFC, 4mm Alucobond Plus
CWCT Certificate for Sotech Optima TFC+ Through Fix Cassette System
FPA Classification Report - BR135 Optima TFC+ System 3mm Ali PPC
FPA Test Report BS8414-2-2015+A1-2017 for Optima TFC+, 3mm Ali PPC
Optima TFC+ Through Fix Cassette Rainscreen System Details
Optima TFC+ Installation Details
Sotech Company Brochure