Verified by manufacturer 10 days ago
Masonry party wall barrier.
Designed to provide fire compartmentation within concealed voids within the external fabric of a masonry wall construction. When installing Mayplas MP552 Masonry Cavity Barriers it may be necessary to consider additional use of DPC’s and/or cavity trays in line with relevant Building Control guidance. Alternatively consider the use of MP557 Acoustic Party Wall DPC which has a DPC pre-attached.
MP552 Masonry Cavity Barrier and MP552 Masonry Party Wall Barrier are polythene enclosed stone mineral wool cavity barriers manufactured in sizes to suit specified cavity widths. MP552 Masonry Cavity Barriers assist in satisfying requirements of guidance documents such as Approved Document B and The Scottish Technical Handbooks. MP552 Masonry Cavity Barriers are suitable for both vertical and horizontal positioning to the edge of cavities such around openings, at compartment lines and to sub-divide cavities.
MP552 Masonry Party Wall Barriers is suitable for use at party wall lines. MP552 is placed at designated positions during erection of masonry which then compresses the barrier between the inner and outer leaf within the cavity creating a seal against smoke and heat transmission.
Features and benefits:
Color | Green |
Material | Polythene Mineral wool Stone wool |
Shape | Rectangle |
Length | 1200 mm |
Width | 180 mm 210 mm 230 mm 260 mm 280 mm |
Height | 50 mm 55 mm 60 mm 70 mm 65 mm |
Uniclass | |
CAWS | F30/18 Cavity closers F30/180 Cavity closers |
To fit cavity width | 35 mm. 40 mm. 45 mm. 50 mm. 55 mm. 60 mm. 65 mm. 70 mm. 75 mm. 80 mm. 85 mm. 90 mm. 95 mm. 100 mm. 105 mm. 110 mm. 115 mm. 120 mm. 125 mm. 130 mm. 135 mm. 140 mm. 145 mm. 150 mm. Manufacturer guidanceMaximum external cavity width. |
Length (effective) | 1200 mm. |
Fire resistance | 60 minutes (E), 60 minutes (I). 90 minutes (E), 90 minutes (I). Manufacturer guidanceMP551 Timber Frame Cavity has been independently tested in accordance with BS EN 1366-4 and subsequently assessed as a Field of Application. Field of application report number WF 547245. |
Cavity width | 50 mm. 75 mm. 100 mm. Manufacturer guidanceParty wall cavity width. |
ThermalConductivity | 0.037 W/mK. |
Country of product manufacture | United Kingdom |
Material | Polythene Mineral wool Stone wool |