NBS Source
I'm a manufacturer

Moisture Vapour Suppressant (MVS) - One-Component Two-Coat Moisture Barrier

Verified by manufacturer 21 hours ago

Nicholls & Clarke

A one-component, two-coat moisture barrier for suppressing residual construction moisture in concrete slabs and cement screeds.

Jump to:
+44 (0)20 8586 4600 Website

Application

For use in suppressing residual construction moisture in concrete slabs and cement screeds.

  • Suitable for use in domestic and commercial installations.
  • Suitable for all kinds of floor covering when in two coats.
  • Suitable for use on heated screeds.

Description

A one-component, two-coat moisture barrier for suppressing residual construction moisture in concrete slabs and cement screeds.

Features and benefits:

  • Suitable for use on sub-floors with up to 95% relative humidity (RH).
  • Fast drying – first coat approx. 30 minutes at 20⁰C.
  • Compatible with a suitable moisture tolerant Nicobond ScreedPro smoothing compound.
  • Easy to apply.
  • Non-flammable.
  • Suitable for use on heated screeds.
  • Excellent coverage.
  • Blue colour to show uniform coverage.
  • Low VOC emissions.
  • Suitable for use in domestic and commercial installations.
  • Supplied in a resealable bottle.

General information

Color

Blue

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_35_31_77_30 Floor surface sealersPrimary

CAWS

M10/680 Surface sealer to wearing screeds

SKU Code

N1580090

Specification data - Floor surface sealers

Classification data

Grade

Moisture vapour suppressant.

Colour

Light blue.

Guidance for specification option:

To show uniform coverage.

Coverage

At 150 g/m² coating a unit will cover approx. 16.5 m² based on a two-coat system.
Approx. six units will be required for 100 m² depending on absorbency of substrate.

Installation temperature

Minimum 10°C (air); 5°C (floor).

Guidance for specification option:

Air temperature should be a minimum of 10⁰C throughout application and curing.

Floor temperature should be a minimum of 5⁰C above the dew point to ensure there is no moisture present at the subfloor surface which may impair adhesion.

Operating temperature

-20 to +70°C.

Literature

Moisture Vapour Suppresant (MVS) Datasheet

Moisture Vapour Suppresant (MVS) Datasheet